SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY THIS MANUAL IS PRINTED ON RECYCLED PAPER 8 2 8 By SHERWOOD INDUSTRIES LTD. Direct Vent OWNERS MANUAL Installation And Operating Instructions For Models: 828 MH (MOBILE HOME) 828 DV. FS. (Freestanding) 828 DV.
SAFETY PRECAUTIONS FOR SAFE INSTALLATION AND OPERATION OF YOUR "ENVIROGAS" ROOM HEATER, PLEASE, CAREFULLY READ THE FOLLOWING INFORMATION: • All "ENVIROGAS" gas-fired appliances must be installed in accordance with these instructions.
TABLE OF CONTENTS 1 Code A pproval s ............................................................................................................. ..............................3 S pecificat ions .......................................................
2 . DIMENSIONS AND CLEARANCES TO COMBUSTIBLES FIREPLACE INSERT: The stove can only be installed in a so lid fuel burning fireplace . Mantle pillar to stove 10” Stove top to 8” wide mantle 12” Mi.
ZERO CLEARANCE BOX ASSEMBLY; First take the kit from the box and place the surround panels as ide so as not to damage the panels. There will also be a bag of screws, nuts and bolts in the box. The bottom section of the kit will have tw o 3 inch square boxes mounted to t he bottom.
3. DECIDING WHERE TO LOCATE YOUR STOVE FREESTANDING: • Locate the stove in a large and open room that is centrally located in the hous e. This will optimize heat circulation and comfort. • The stove should be located out of traffic, away from furniture and draperies and should have sufficient access for its safe operation and maintenance.
FIREPLACE INSERT • Carefully clean the fireplace and flue before in stalling the stove. Failure to do so ma y result in fumes or dirt being blown i nto the room or insert and may cause a fire leading to death or serious injury. • If you are installing the optional fan ki t, (see Installing Fan Kit) do so now .
5. INSTALLING BURNER CONTROL ASSEMBLY Remove the controls from box, che ck for shipping damage. Remove burner tray from controls (one scr ew on each side between burners). Open door. Remove grate rod by pu lling up at each end. Remove the 2 screws behind the grate and one screw on each side of control opening in firebox.
2. Place the log with Burnt Area forward on log supports. Locate the log by matching the bottom pegs to the receiving holes in rear log supports. 3. Close door securely 7. ELECTRICAL REQUIREMENTS T he ENVIROGAS 828 Series w ill operate wit hout an external electrical pow er supply.
8. GAS LINE CONNECTION AND TESTING WA RNING: Only persons licensed to w ork w ith gas piping can make the gas connections to this appliance. This appliance is equipped with a 3/8” stainless steel flex line from the valve. This line ma y be routed through the hole in the rear of the pedestal, or on inserts, routed through the fire box sides.
9. AIR SHUTTER ADJUSTMENT • There is a separate venturi air shutter for each burner • The venturies have been set for installation at sea level to 4,500 ft. • To adjust for higher altitudes : Remove the access cover plate, loosen the air shutter locking screws w ith a long screw driver.
10. VENTING VENT TERMINATION CLEARANCES A= Clearance above grade, ve randah, porch, deck, or [balcony (*12 inches (30cm) minimum] B= Clearance to window or door that may be opened [*12 inches (30cm) m.
These models have been tested and certified for use with SIMPSON DURAVENT DIRECT VENT TYPE "GS" PIPE FOR GAS STOVE. Kits are available for vertical venting or horizontal ve nting. It is recommended that a bead of RTV High Temperature Silicone be applied to each vent joint before installation.
When planning your installation, it w ill be necessary to select the proper length of vent pipe fo r y our particular requirements . It is important to note when passing thr ough a wall, the max imum allowable w all thickness is 10-inches (254mm), 1 ½ inches clearance to combustibles must be maintained.
STEP 7. Slide the decorative wall thimble up to the wall su rface and attach with the screws provided. Apply decorative brass or chrome trim if desired. FIG-14. FIG. 11 FIG. 12 FIG-13 FIG-14 NOTES: (1) The four wood screws provided should be replaced with th e appropriate fasteners for stucco, brick, concrete, or other types of siding.
VERTICAL INSTALLATION STEP 1. Check the instructions for required clearances (air spaces) to combustibles w hen passing through ceilings, walls, roofs, enclosures, attic rafters , or other nearby combustibl e surfaces. Do not pack air spaces w ith insulation.
NOTES: (1) If an offset is necessary in the attic to avoid obstruc tions, it is important to support the vent pipe every 3 feet, to avoid excessive stress on the elbows, and possible separation. Wall straps are available for this purpose. FIG- 18 (2) When ever possible, use 45 ° degree elbows instead of 90 ° degree elbows.
CATHEDRAL CEILING INSTALLATION Step 1. Follow installation steps 1 and 2 under Vertical Termination. Step 2. Using the plumb bob, mark the centerline of the venting system on the ceiling and drill a small hole through the ceiling and roof at this point.
11. MOBILE HOME FUEL CONVERSION To conve rt from Propane to Natural Gas or v ise-versa 1. Disconnect the unit from the gas supply. 2. Open the door and remove the logset. 3. Remove the burner tray (2 screw s) and the burner control assembly by removing the 8 screw s holding it into the unit.
12. OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIO NS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE , PERSONAL INJURY OR LOSS OF LIFE. A) This appliance is equipped with a pilot that must be lit by hand by following these instructions exactly.
13. MAINTENANCE AND TECHNICAL Periodically check to ensure that your "Direct Vent" sy stem is clear. Periodically check the pilot and burner. Check to see that all the burner ports are clean and clear. Check the pilot head for blockage. Check to ensure the pilot flame is blue wi th small yellow tips.
14. TROUBLE SHOOTING Problem Possible Cause Solution Spark will not light the pilot after repeated pressing of spark ignitor Defective piezo ignitor Check connections to ignitor -If ignitor connection.
15. PARTS AND ACCESSORIES Service Parts available from your local Envirogas Dealer. PA RT # DESCRIPTION 828-001 Convection Blower 828-002 Heyco Strain Relief 828-003 2-Speed Fan Switch 828-004 Eurosit.
16. WARRANTY Sherwood Industries Ltd. offers a *Lifetime Warranty on this gas product. The lifet ime warranty covers the appliance for a period of seven years from the date of installation.
17. INSTALLATION DATA SHEET The installer for warranty purposes and future re ference must record the following information. Envirogas Models: 828.DV. FS.
Ein wichtiger Punkt beim Kauf des Geräts Enviro 828 DV.FS. (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Enviro 828 DV.FS. noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Enviro 828 DV.FS. - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Enviro 828 DV.FS. reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Enviro 828 DV.FS. erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Enviro 828 DV.FS. besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Enviro 828 DV.FS. verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Enviro 828 DV.FS.. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Enviro 828 DV.FS. gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.