EVOLUTION PELLET STOVE INSTALLATION & OP ERATION MANUAL CAUTION Please read this entire manual before in stallation and use of this pellet fuel- burning appliance. Keep children, furnitu re, fixtures and all combustibles away from any heating appliance.
Page | 2 WARNING : Use of outside combustion air is mandatory with this unit. Do not operate with the hoppe r open; lid must be shut and tightly latched during operation.
Page | 3 TABLE OF CONTENTS Introduction Introduction ...................................4 Specifications Heating Specifications ..................5 Dimensions ...................................5 EPA Compliance ........................
Page | 4 INTRODUCTION Thank you for purchasing this fi ne product from England’s Stove Works! England’s Stove Works was started, and is still ow ned by, a family that believes strongly in a “Do It Yourself” spirit; that’s one reason you found this product at your favo rite “Do It Yourself” st ore.
Page | 5 SPECIFICATIONS Heating Specifications Heat Output Range** ............................................ 10,700 BTU/hr – 25,100 BTU/hr Approximate Pellet Burn Rate** ............................................... 1.6 lb/hr – 3.9 lb/hr Maximum Burn Time** .
Page | 6 SPECIFICATIONS FIREPLACE INSERT DIMENSIONS Unit Height (In Fireplace) o 20.00” [508mm] Unit Depth (In Fireplace) o 9-7/16” [239.7mm] Unit Width (In Fireplace) o 21-3/16” [538.2mm] Bottom to Flue Collar o 7-1/4” [184.2mm] Left Side to Flue Collar o 5-1/2” [139.
Page | 7 FREESTANDING INSTALLATION (Note: For Fireplace Insert Installation, see Fireplace Insert In stallation section on Page 17) Installation Overview When choosing a location for your ne w stove, there are a multitude of factors that should be taken into acc ount before beginning the installation.
Page | 8 FREESTANDING INSTALLATION Clearances to Combustibles Unit Clearances to Combustibles Side ( A ) Rear ( B ) Corner ( D ) Min. Alcove Height Min. Alcove Width 6 IN.
Page | 9 FREESTANDING INSTALLATION Venting Introduction This pellet stove operates on a ne gative draft system, which pulls combustion air through the burn pot and pushe s the exhaust air to the vent pipe and out of the building.
Page | 10 FREESTANDING INSTALLATION Additional Venting Information Do not mix and match com ponents fro m different pipe manufacturers when assembling your venting system (i.e. Do NOT use venting pipe from one manufacturer and a thimble from another).
Page | 11 FREESTANDING INSTALLATION Approved Venting Method 1 : Through the Wall Generally the simplest in stallation method, venting through the wall using our AC-3000 kit (or similar venting system) is also the preferred venting method.
Page | 12 FREESTANDING INSTALLATION Approved Venting Method 2 : Through the Ceiling Venting through the ceiling/ roof may be the only feasible venting option in so me cases and is a factory recommended installation.
Page | 13 FREESTANDING INSTALLATION Approved Venting Method 3 : Existing Chimney System Using an existing masonry or factory built chimney for venting is the only other acceptable m ethod for venting this pellet unit. Use Type L or Type PL venting pipe until entering the existing chimney.
Page | 14 FREESTANDING INSTALLATION Mobile Home Installation As with all installations involving this unit, the use of outside combustion air is mandatory and MUST be used. Please see the “Out side Air” section on page 15 for more information regarding outside air connections.
Page | 15 OUTSIDE AIR HOOK-UP The use of outside combustion air is mandatory on the 25-EP. The outside air connection pipe protrude s from the lower rear center of the stove; use the included outside air kit to attach your stove to outside combustion air.
Page | 16 FREESTANDING FLOOR PROTECTION The 25-EP requires a non-combustible floor protector if the stove is to be installed on a combustible floor.
Page | 17 FIREPLACE INSERT INSTALLATION (Note: For Freestanding Installation, see Fr eestanding Installation section on Page 7) Insert Assembly – Be certain the stove is unplugged and cooled down Instructions 1.
Page | 18 FIREPLACE INSERT INSTALLATION Insert Assembly Continued 6. Use the included self-drilling sheet me tal screws to scre w the Rear Hopper Cover Plate to the hopper of the stove while carefully holding the lid in place to be certain in remains centered on the stove.
Page | 19 FIREPLACE INSERT INSTALLATION Clearances to Combustibles Unit Clearances to Combustibles Clearance to Mantle (A) Side (B) 16 IN. 6 IN. 406.4 MM. 152.4 MM. WARNING INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.
Page | 20 FIREPLACE INSERT INSTALLATION Venting Introduction This pellet stove operates on a ne gative draft system, which pulls combustion air through the burn pot and pushe s the exhaust air to the vent pipe and out of the building.
Page | 21 FIREPLACE INSERT INSTALLATION Additional Venting Information The installation of a fireplace inse rt can be challenging and requires knowledge of chimney systems that th e average homeowner does not have. Due to this, England’s Stove Works highly recommends having this insert professionally installed.
Page | 22 FIREPLACE INSERT INSTALLATION Approved Venting Method : Full Chimney Relining Use a chimney liner system specifically designed for pellet stove use; follow the guidelines in the previous section regarding appropriate liner diameter.
Page | 23 OUTSIDE AIR HOOK-UP The use of outside combustion air is mandatory on the 25-EP Insert. The outside air connection pipe protrude s from the lower rear center of the stove; use the included outside air kit to attach your stove to outside combustion air.
Page | 24 FLOOR PROTECTION The 25-EPI requires a non-combustible hearth if the current hearth of the fireplace does not extend the required dist ance from the front of stove. Follow the diagram below to determine if the cu rrent fireplace hearth is sufficient.
Page | 25 DAILY OPERATION Getting Started Check to see that th e hopper is clean and free from fo reign materials. Be sure to connect this unit to a working outle t; we recommend using a surge protector to help protect the electr onic components from damage.
Page | 26 The 25-EP will perform equally well usi ng softwood and hardwood pellets, and although the ash may differ slightly in a ppearance or texture, both types of pellets will burn cleanly and efficiently in this stove.
Page | 27 CONTROL BOARD SETTINGS The control board on this stove allows th e user to adjust the heat output and convection blower speed, turn the unit on and off, and test co mponents for function (more on diagnostic mode later).
Page | 28 ERROR CODES Error codes, or “E-Codes,” are alphanumeric codes that will appear in the Heat Range and Blower Speed windows of the C ontrol Board if the unit experiences an abnormal condition.
Page | 29 POWER FAILURE If the power to the unit is interrupte d for approximately t hree minutes or less, the unit will resume operation when power is restored according to the following table: Unit.
Page | 30 THERMOSTAT OPERATION Thermostat Installation 1. Unplug the unit and remove the back panel of the stove. 2. Locate the thermostat connect block, la beled J18, on the rear of the control board, near the bottom (See image belo w and pg. 52 of this manual for a control board diagram).
Page | 31 THERMOSTAT OPERATION Thermostat Operation Details The 25-EP was designed to operate equally we ll in both manual and thermostat mode. While using the control board for heating c ontrol g.
Page | 32 DAILY MAINTENANCE Important Notes As with any maintenance concerning this unit, be sure the unit is “OFF” and has completed the Shut-Down cycle BEFORE beginning. Be aware that metal parts in the firebox can remain HOT long after the fire has gone out and EVEN after the Shut-Down cycle is complet e.
Page | 33 DAILY MAINTENANCE Ash Removal and Disposal Press the “Off” button and allow the stove to complete the shut-down cycle and cool completely. Grasp the heat exchange cleaning rod lo cated at the middle of the decorative room air grill and repeatedly pull it in and out until ash stops falling from the tubes into the firebox.
Page | 34 DAILY MAINTENANCE Cleaning the Burnpot Along with removing ashes from the stove, cleaning the burnpot is the other essential part of daily maintenance that will keep the stove operating at its peak. Pellets contain varying amounts of impur ities and fusible m aterial that will accumulate in the burnpot over time.
Page | 35 BIWEEKLY MAINTENANCE Important Notes As with any maintenance concerning this unit, be sure the unit is “OFF,” has completed the Shut-Down cycl e, and is completely cool BEFORE beginning. Be aware that metal parts in the firebox can remain HOT long after the fire has gone out and EVEN after the Shut-Down cycle is complet e.
Page | 36 BIWEEKLY MAINTENANCE Baffle Removal Using the integral tube cleaner, as mentioned in the Daily Maintenance section, helps to keep the heat exch anger tubes free from fly ash; however, fly ash will still accumulate on the baffl e shelf and in other non-visible areas.
Page | 37 MONTHLY MAINTENANCE Important Notes As with any maintenance concerning this unit, be sure the unit is “OFF,” has completed the Shut-Down cycl e, and is completely cool BEFORE beginning. Be aware that metal parts in the firebox can remain HOT long after the fire has gone out and EVEN after the Shut-Down cycle is complet e.
Page | 38 MONTHLY MAINTENANCE Exhaust Chamber Cleaning The exhaust chamber of the stove wa s intentionally designed as an ash accumulation area. Allowing ash to accumu lat e here prevents excess ash build-up in the combustion blower and the venting system.
Page | 39 MONTHLY MAINTENANCE Venting Pipe Cleaning Low spots and direction changes in th e venting system (such as tee’s and elbows) are areas for potential fly-ash accumulation. INSPECT these areas diligently to keep the venting sy stem in safe operating condition.
Page | 40 YEARLY MAINTENANCE Important Notes As with any maintenance concerning this unit, be sure the unit is “OFF,” has completed the Shut-Down cycl e, and is completely cool BEFORE beginning. Be aware that metal parts in the firebox can remain HOT long after the fire has gone out and EVEN after the Shut-Down cycle is complet e.
Page | 41 YEARLY MAINTENANCE Exhaust Blower Cleaning Although the exhaust blower and blower housing were designed to minimize ash build-up, some fly-ash will still accumulate there throughout the burning season. The amount and type of ash will depend on th e type of pellets and venting system, but generally this accumulation will be mild.
Page | 42 Loosen and remove the 5/16” screw, on the top of the exhaust blower output connection, which holds the therma l sensor to the exhaust blower. Loosen the five (5) 5/16” self-drilling screws which hold the exhaust blower to the exhaust blower tube.
Page | 43 YEARLY MAINTENANCE Convection Blower Cleaning As always, be certain the stove is cool and unplugged before servicing any components within the unit. Since th e convection blower does not handle any by-products of combustion, it does not require serious clean ing like the exhaust blower.
Page | 44 YEARLY MAINTENANCE Checking Gaskets An airtight seal at the door openings a nd hopper lid opening is crucial to proper stove performance. Any air leaks at these areas can not only cause a dirty, inefficient burn but can also pose a serious safety threat.
Page | 45 Trouble ‐ Shooting Guide WARNING: To avoid ELECTRICAL SHOCK always disconnect the unit from the power source BEFORE attempting any repair.
Page | 46 2. Loose exhaust fan set screw. 2. Check set scr ew for tightness. "E ‐ 1" Code On Control Board 1. Vacuum bypass chip missing. 1. Contact Te chnical Support.
Page | 47 REPLACING COMPONENTS Auger Motor 1. Before beginning any component replacement, be certain the unit is unplugged and thoroughly cooled down. Also, make sure th e hopper is empty before attempting to remove or replace the auger m otor assembly.
Page | 48 REPLACING COMPONENTS Convection Blower 1. Before beginning any component replacement, be certain the unit is unplugged and thoroughly cooled down. 2. Freestanding: Remove the right side panel as previously detailed in this manual on Page 41 in the “Exhaust Blower Cleaning” se ction.
Page | 49 REPLACING COMPONENTS Vacuum Switch 1. Before beginning any component replacement, be certain the unit is unplugged and thoroughly cooled down. 2. Remove the right side panel and the back panel as previously detailed. 3. Locate the vacuum sensor as shown in the diagram below.
Page | 50 REPLACING COMPONENTS Gaskets 1. Door o This unit comes with a 1 / 2 ” rope gasket around the door th at should be replaced at least every two years.
Page | 51 REPLACING COMPONENTS Control Board The Control Board (Part # PU-CBEP) is a digi tal read-out board. This board offers a wide variety of settings to operate the unit. The right side panel should be removed prior to removing the control board (freestanding unit).
Page | 52 WIRING DIAGRAM Caution – Shock Hazard Press the “Off” button and let the a ppliance completely cool BEFORE unplugging the appliance and beginni ng a ny maintenance or component replacement. Risk of shock if appliance is not unplugged before service.
Page | 53 OPTIONAL ACCESSORIES Wall Thermostat (PU-DTS TAT) Installing this wall thermostat allo ws the 25-EP to operate on the same principle as a furnace: The stove will shut -down and relight as the call for heat comes and goes. This will maintain the house at a more constant temperature, while conserving pellets.
Page | 54 ILLUSTRATED PARTS DIAGRAM - FREESTANDING Auger Motor Assembly Steel Door Assembly Freestanding and Fireplace Insert.
Page | 55 ILLUSTRATED PARTS DIAGRAM – INSERT.
Page | 56 Part Number Part Description Diagram # Gaskets PU ‐ HLG Hopper Lid Gasket 1 AC ‐ DGKEP Door Gasket 2 AC ‐ GGKEP Three Piece .
Page | 57 You may write your unit’s Manufacture Date and Serial Number in the blank spaces on this sample tag, for future reference. This sample tag also shows the safety info. such as UL testing standard, etc. for your local officials, or a nyone else who may need reference information.
Page | 58 LIMITED FIVE (5) YEAR WARRANTY From the date of purchas e to the original owner The manufacturer extends the following warranties: Five Year Period: 1. Carbon steel and welded seams in the firebox are covered for five (5) years against splitting.
Page | 59 Procedure Purchaser must give notice of claim of defect within the warranty period and pay transportation to and from a service center designated by the manufacturer. The dealer from which the un it was purchased or the factory, at our option, will perform the warranty service.
Page | 60.
Page | 61 WARRANTY REGISTRATION for England’s Stove Works® Purchaser Information I. Purchased By (Name) ______ ___________________________________ II. Address ____________________ __________________ ______________ III. City________________ _______State________Zip Code ____________ IV.
Page | 62 Important Notice This registration information MUST be on file for this warranty to be valid. Please mail this information within thirty (30) days from the original date of purchase. Use any of these three easy ways to send your warranty information in! Mailing Address England’s Stove Works, Inc.
Ein wichtiger Punkt beim Kauf des Geräts England's Stove Works 55-TRPEPI (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie England's Stove Works 55-TRPEPI noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für England's Stove Works 55-TRPEPI - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von England's Stove Works 55-TRPEPI reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über England's Stove Works 55-TRPEPI erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon England's Stove Works 55-TRPEPI besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von England's Stove Works 55-TRPEPI verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit England's Stove Works 55-TRPEPI. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei England's Stove Works 55-TRPEPI gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.