Benutzeranleitung / Produktwartung STM150 des Produzenten 3M
Zur Seite of 12
INSTR4089 1006 Owner’s Manual This manual is for the installation, operation, and maintenance of the ScaleGard ™ PLUS 2 Water Treatment Systems STM150 TSR150 ™ Installer please leav e manual with end user .
SAFETY INFORMATION CAUTION IMPORTANT NOTES Read, understand, and follow all safety information contained in these instructions prior to installation and use of the CUNO Foodservice STM150/TSR150 ScaleGard™ PLUS 2 W ater T reatment Systems . Retain these instructions for future reference.
Contents Installation Requirements Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Feedwater Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Electrical Requirements .
Important: Installation Requirements To reduce the risk associated with property damage due to water leakage: • Installation must comply with existing state or local plumbing codes; • Read and follow Use Instructions before installation and use of this system.
m e t s y S O R 0 5 1 M T S s u l P v e B s m e t s y S R S T y l p p u S r e t a W e c i v r e S o T k n a T O R e v l a V k c e h C k n a T l a u n a M e v l a V e n i L r e t a W O R " 8 / 3 .
Installation Procedure To reduce the risk associated with property damage due to water leakage: • Installation must comply with existing state or local plumbing codes; • Read and follow Use Instructions before installation and use of this system.
The water pressure in the tank will increase as the tank fills with water. When the pressure in the tank reaches approxi- mately 80 psi (552 kPa) the filter system shuts off. When water is drawn from the tank and the pressure drops to approximately 60 psi (414 kPa), the filter system will automatical- ly turn on.
Start-Up Procedure 1. Check air pressure in the storage tank, Refer to Storage Tank Installation. (page 6) 2. Close all water valves (5) in the system. (page 4) 3. Open water supply valve at the connection to the main water feed and the inlet water valve at the unit.
TDS Reduction Filter (M) Replacement Procedure [annually] 1. De-pressurize the system as instructed above. 2. Locate the TDS reduction filter. To remove the TDS reduction filter, turn to the left 1/4 turn. Pull down to remove. 3. Disconnect reject tubing by pushing in the white collet on plastic fitting to release the tubing (see page 9).
2 T ubing is secured in. Grey Collet T ube Push tubing straight in as far as it will go. 1 Pull tubing straight out. 2 T o Attach T ubing 1 Push in grey collet to release tubing. T o Release T ubing ‘Push-In’ Tubing Connector (John Guest® Fitting) This product is outfitted with user friendly “Push In” connectors.
4 3 2 9 10 5 8 7 1 6 Item # Description STM150 TSR150-2 1 Sediment Filter (S) 55997-01 55997-01 2 Chlorine Reduction Filter (C) 55995-01 55995-01 3 TDS Reduction Filter (M) 55987-07 55987-07 4 Ion Med.
© 2007 3M Company. All rights reserved. CUNO Incorporated 400 Research Parkway Meriden, CT 06450, USA Toll Free: 1-888-218-CUNO Worldwide: 203-237-5541 Fax: 203-238-8701 www.cunofoodservice.com • www.cuno.com a 3M company CUNO and ScaleGard are trademarks of 3M Company used under license.
Ein wichtiger Punkt beim Kauf des Geräts 3M STM150 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie 3M STM150 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für 3M STM150 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von 3M STM150 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über 3M STM150 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon 3M STM150 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von 3M STM150 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit 3M STM150. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei 3M STM150 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.