Benutzeranleitung / Produktwartung RX 1200 des Produzenten Elinchrom
Zur Seite of 16
English elinca sa switzerland www .elinchr om.com Operating Manual Style RX 300 Style RX 600 Style RX 1200 Elinca S.A Style RX 01.01.2007 ENG (73253) Printed in S witzerland Version 230V - 20625 Version 230V - 20626 Version 230V - 20627 120V - 20725 120V - 20726 120V - 20727 Canada 120V - 20725.
1 P .S: T echnical data subject to change. The listed values ar e guide values which may vary due to tolerances in components used. Introduction 2 Declaration of conformit y , disposal and recycling, .
2 The quality of light and ex ceptional performance is the result of long research, application of demanding principles, the long experience of ELINCHROM in lighting products for the studio and the utilization of the latest technology in this area.
3 CE marking The shipped v ersion of this device complies with the requirements of ECC directives 89/336/ECC «Electromagnetic compatibi lity» and 73/23/ECC «Low voltage directiv e». Notational Conventions The meaning of the symbols and fonts used in this manual are as f ollows: P ay particular attention to text marked with this symbol.
4 Transport • T ransport the ash unit with care and only in its original packaging or another corresponding packaging t to protect it against knocks and jolts. • T ransport only in complete discharged conditions. W ait a minimum 30 minutes after removing from mains supply befor e packaging and transportation.
5 B protective cover 3 1 6 11 12 The Style RX unit voltage must correspond with y our mains voltage. Style RX are delivered in 120V or 230V versions. Before connecting for the rst time, check to mak e sure that your Modelling lamp coincides with the voltage line.
6 Overview of controls 1.Mains inlet socket 2.Mains fuse (slow blow) 3.Mains Illuminated on/off switch 4.Modelling fuse (f ast blow) 5.Open-ash 6.Synchro-sockets, Amphenol + jack 3.5 mm 7 .Digital power display and charge/discharge indicator 8. Acoustic recharging signal (Beep) 9.
2 3 1 Mains fuse 8 A T Modelling fuse 4 AF Mains switch (Only tempered) Mains socket 4 Mains Supply With the MAINS SWITCH (3) switched off ("O" position), rmly push in the plug of the original ELINCHROM mains cord into the mains socket (1).
8 23018 23101 23022 230V Modelling lamps and fuses Unit Modelling lamp Code Socket Fuse Code Style 300RX 250W halostar 23018 E27 2,5AF 19033 Style 600RX 250W halostar 23018 E27 2,5AF 19033 Style 1200RX 300W halogen 23022 GX 6,35 2,5AF 19033 The touch pad (14) controls the modelling lamp on/off and the proportional light.
9 Photocell receptor (10) T est and ready (5) Cell (9) Modellling light controls Power displa y The actual ash power is displayed in a f -stop compatible format. The power range is 6 f -stops. The digital display , provides continuous power indication of the ash and modelling lamp.
6 10 Audible recharge signal Select the function with the touch pad (8), the green indicator appears. Once recycled an acoustic signal indicates that the compact unit is ready . Open ash "test" Having pressed the touch pad to release a ash, the green «READ Y» light will appear again once the unit is recharged.
11 If the unit does not ash but the ON/OFF switch indicates that there is power , it could be that the ashtube needs replacing. Note: Flash tubes (Swiss quality) have a long life with average us.
12 Flash power J(Ws) 300 600 1200 Power supply 230V V ersion V all units 215-240 120V V ersion V all units 110-120 F-stop, 1m, 100 ISO , with reector 48° GN 64,1 90,1 128,1 Control range J(Ws) 9-3.
13 code Reectors Wide angle ø 16 cm /90° 26143 Compact ø 18 cm /60° 26144 Standard ø 21 cm /50° 26141 Mini Soft ø 44 cm silver 26166 Mini Soft ø 44 cm white 26168 Snoot & Grid 26061 Gri.
14 This ELINCHROM product will be repaired free of char ge by the vending agent if during a period of 24 months from date of purchase its working order is impaired thr ough a manufacturing or material defect. The fault y product should be immediately sent to the authorized dealer or ELINCA agent.
www.elinchrom.com.
Ein wichtiger Punkt beim Kauf des Geräts Elinchrom RX 1200 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Elinchrom RX 1200 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Elinchrom RX 1200 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Elinchrom RX 1200 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Elinchrom RX 1200 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Elinchrom RX 1200 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Elinchrom RX 1200 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Elinchrom RX 1200. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Elinchrom RX 1200 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.