Power Blower Operator's Manual MODELS PB-500H PB-500T W ARNING Read rules for safe operation and all instructions carefully . ECHO provides this Operator's Manual which must be read and understood for proper and safe opera- tion.
2 I n t r o d u c t I o n W elcome to the ECHO family . This ECHO product was designed and manufactured to provide long life and on-the- job-dependability . Read and understand this manual. Y ou will nd it easy to use and full of helpful operating tips and SAFETY messages.
3 P o w e r B l o w e r o P e r a t o r ' s M a n u a l I n t e r n a t I o n a l s y m b o l s Symbol description/application Symbol form/shape Symbol description/application Symbol form/shape Read and understand Operator's Manual.
4 Physical Condition Y our judgment and physical dexterity may not be good: • if you are tired or sick, • if you are taking medication, • if you have taken alcohol or drugs. Operate unit only if you are physically and mentally well. Eye Protection W ear eye protection that meets ANSI Z87.
5 P o w e r B l o w e r o P e r a t o r ' s M a n u a l DANGER Do not operate this product indoors or in inadequately ventilated areas. Engine exhaust contains poisonous emissions and can cause serious injury or death.
6 W ARNING Use only ECHO approved attachments. Serious injury may result from the use of a non-approved attachment com - bination. ECHO, INC. will not be responsible for the failure of cutting devices, attachments or accessories which have not been tested and approved by ECHO.
7 P o w e r B l o w e r o P e r a t o r ' s M a n u a l 10 11 12 1 2 3 5 6 7 4 d e s c r I p t I o n PB-500H Locate these safety decals on your unit. Make sure the decals are legible and that you understand and follow the instruc- tions on them. If a decal cannot be read, a new one can be ordered from your ECHO dealer .
8 1. SAFETY DECAL - Lists important safety precautions. 2. SP ARK PLUG - Provides spark to ignite fuel mixture. 3. SP ARK ARRESTOR MUFFLER OR SP ARK ARRESTOR MUFFLER WITH CA T AL YST - The mufer or catalytic mufer controls exhaust noise and emission.
9 P o w e r B l o w e r o P e r a t o r ' s M a n u a l 10 11 12 13 14 6 15 P/N X505002080 General W arning Decal (located on blower housing) P/N X505002310 Hot Decal (near mufer) 70 Category II dB(A) Measured at 50 ft.
10 1. SAFETY DECAL - Lists important safety precautions. 2. SP ARK PLUG - Provides spark to ignite fuel mixture. 3. SP ARK ARRESTOR MUFFLER OR SP ARK ARRESTOR MUFFLER WITH CA T AL YST - The mufer or catalytic mufer controls exhaust noise and emission.
11 P o w e r B l o w e r o P e r a t o r ' s M a n u a l c o n t e n t s PB-500H ___ 1 - Power Head ___ 1 - Flex Pipe ___ 1 - Pipe w/swivel ___ 1 - Straight Pipe ___ 1 - Straight Pipe w/decal ___.
12 a s s e m b l y PB-500H W ARNING Never perform maintenance or assembly procedures with engine running or serious personal injury may result. I n s t a l l b l o w e r p I p e s / s t I c k h a n d l e 1. Assemble clamps (A) onto both ends of exible pipe (B).
13 P o w e r B l o w e r o P e r a t o r ' s M a n u a l G PB-500T W ARNING Never perform maintenance or assembly procedures with engine running or serious personal injury may result. I n s t a l l b l o w e r p I p e s ( t ) 1. Place guide loop (G) across clamp, and turn until clip fully engages clamp band.
14 NOTICE: Use of unmixed, improperly mixed, or fuel older than 90 days, (stale fuel), may cause hard starting, poor performance, or severe engine damage and void the product warranty . Read and follow instructions in the Storage section of this manual.
15 P o w e r B l o w e r o P e r a t o r ' s M a n u a l Mixing Instructions 1. Fill an approved fuel container with half of the required amount of gasoline. 2. Add the proper amount of 2-stroke oil to gasoline. 3. Close container and shake to mix oil with gasoline.
16 s t a r t I n g c o l d e n g I n e • Recoil starter: Use short pulls - only 1/2-2/3 of rope length for start - ing. Do not allow the rope to snap back in. Always hold the unit rmly . • (PB-500H): Rotate spring loaded throttle arm downward to a com - fortable operating position.
17 P o w e r B l o w e r o P e r a t o r ' s M a n u a l s t a r t I n g w a r m e n g I n e The starting procedure is the same as Cold Start except DO NOT close the choke. PB-500H 1. Thr ottle Lever Move throttle position lever (A) midway between idle and full throttle positions.
18 o p e r a t I n g b l o w e r W ARNING Engine exhaust IS HOT , and contains Carbon Monoxide (CO), a poison gas. Breathing CO can cause unconsciousness, serious in- jury , or death. Exhaust can cause serious burns. AL W A YS position unit so that exhaust is directed away from your face and body .
19 P o w e r B l o w e r o P e r a t o r ' s M a n u a l m a I n t e n a n c e I n t e r v a l s m a I n t e n a n c e Y our ECHO blower is designed to provide many hours of trouble free service. Regular scheduled maintenance will help your blower achieve that goal.
20 a I r f I l t e r Level 1. T ools r equir ed: 25 - 50 mm (1 - 2 in.) cleaning brush. Parts r equir ed: Repower TM T une Up Kit NOTE Clean daily . 1. Close choke (Cold Start Position [ ]). This prevents dirt from entering the carburetor throat when the air lter is removed.
21 P o w e r B l o w e r o P e r a t o r ' s M a n u a l s p a r k p l u g Level 1. T ools r equir ed: 3/4 in. Spark Plug deep socket, Feeler gauge Parts Requir ed: Repower TM T une Up Kit IMPOR T ANT Use only NGK BPM8Y spark plug (BPMR8Y in Canada) other - wise severe engine damage may occur .
22 e x h a u s t s y s t e m Spark Arrestor Screen Level 2. T ools r equir ed: Cross Head Screwdriver Parts Requir ed: Spark arrestor screen, Gasket IMPOR T ANT Carbon deposits in mufer will cause a drop in engine output and overheating. Spark arrestor screen must be checked periodically .
23 P o w e r B l o w e r o P e r a t o r ' s M a n u a l Exhaust Port Cleaning Level 2 T ools r equir ed: W ood or plastic scraper , Cross Head Screwdriver , 4 & 5mm Hex W rench Parts Requir ed: As needed: Mufer gasket 1. Remove spark plug lead from spark plug, and remove engine cover (5 screws).
24 c a r b u r e t o r a d j u s t m e n t Engine Break-In New engines must be operated a minimum duration of two tanks of fuel break-in before carburetor adjustments can be made. During the break- in period your engine performance will increase and exhaust emissions will stabilize.
25 P o w e r B l o w e r o P e r a t o r ' s M a n u a l DANGER Fuel vapors are extremely ammable and may cause re and/or explosion. Never test for ignition spark by ground- ing spark plug near cylinder plug hole, otherwise serious personal injury may result.
26 s t o r a g e W ARNING During operation the mufer or catalytic mufer and surrounding cover become hot. Always keep exhaust area clear of ammable debris during transportation or when storing, otherwise serious property damage or personal injury may result.
27 P o w e r B l o w e r o P e r a t o r ' s M a n u a l s p e c I f I c a t I o n s MODEL ---------------------------------------------------- PB-500H, PB-500T Length PB-500H ------------------------------------------ 380mm (15.0 in.) Length PB-500T ------------------------------------------- 328mm (12.
28 ECHO LIMITED W ARRANTY ST A TEMENT FOR PRODUCT SOLD IN USA AND CANADA BEGINNING 01/01/2010 ECHO'S RESPONSIBILITY ECHO Incorporated’s Limited W arranty , provides to the original purchaser that this ECHO product is free from de fects in material and workmanship .
29 P o w e r B l o w e r o P e r a t o r ' s M a n u a l PURCHASED REP AIR P ARTS, SHORT BLOCKS AND ACCESSORIES .
30 ECHO INCORPORA TED EMISSION CONTROL W ARRANTY ST A TEMENT FOR ECHO AND SHINDAIWA BRANDS The Environmental Protection Agency (EP A) and the California Air Resources Board (C.A.R.B.) and ECHO Incorporated (ECHO Inc.) are pleased to explain the emission control system warranty on your 2010 and later equipment/small of f-road engine (SORE).
31 P o w e r B l o w e r o P e r a t o r ' s M a n u a l n o t e s.
ECHO, INCORPORA TED 400 O a k w O O d R O a d L a k e Z u R i c h , iL 60047 www .echo-usa.com CONSUMER PRODUCT SUPPORT 1-800-673-1558 8:30 - 4:30 Mon - Fri C.
Ein wichtiger Punkt beim Kauf des Geräts Echo PB-500T (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Echo PB-500T noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Echo PB-500T - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Echo PB-500T reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Echo PB-500T erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Echo PB-500T besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Echo PB-500T verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Echo PB-500T. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Echo PB-500T gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.