1 INST ALLA TION INSTRUCTIONS REVISION: Form No. 3109395.066 8/07 (Replaces 3109395.058) (French 3109660.063) ©2007 Dometic Corporation LaGrange, IN 46761 INST ALLA TION INSTRUCTIONS Lire et comprendre ce manuel avant de procéder à l’installation, à des réglages, de l’entretien ou des réparati ons.
2 INST ALLA TION INSTRUCTIONS SAFETY INSTRUCTIONS This manual has safety information and instructions to help users eliminate or reduce the risk of accidents and injuries. RECOGNIZE SAFETY INFORMA TION This is the safety-alert symbol. When you see this symbol in this manual, be alert to the potential for personal injury .
3 INST ALLA TION INSTRUCTIONS SPECIFICA TIONS 120V AC, 60 HZ., 1PH. 12 AWG Copper up to 24’ * For wire lengths over 24 ft. consult the National Electric Code for proper sizing. ** Dometic Corporation gives GENERAL guidelines for generator requirements.
4 INST ALLA TION INSTRUCTIONS INST ALLA TION INSTRUCTIONS 1. PRECAUTIONS Improper insta llation may damage equipment/could endanger life, cause serious injury and/or property damage. A. Read Installation and Operating Instructions carefully before attempting to start your air conditioner installa- tion.
5 INST ALLA TION INSTRUCTIONS C. AFTER LOCA TION HAS BEEN SELECTED: 1. Check for obstructions in the area where air condi- tioner will be installed. 2. The roof must be designed to support 130 pounds when the RV is in motion. Normally a 200 lb. static load design will meet this requirement.
6 INST ALLA TION INSTRUCTIONS It is the responsibility of the installer of this air condi- tioner system to ensure structural integrity of the RV roof. Never create a low spot on the roof where water will collect. W ater standing around the air conditioner ma y lea k int o the inte ri or caus in g da mage to the pro du ct and the RV .
7 INST ALLA TION INSTRUCTIONS 3. A 3/8” diameter hole will be needed to route the cable through the wall. B. CONTROL CABLE INST ALLA TION A 4-conductor control cable must be routed from the roof opening to the Comfort Control Center ™.
8 INST ALLA TION INSTRUCTIONS 6. DISCHARGE DUCT & CEILING TEMPLA TE INST ALLA TION A. Remove the air box and mounting hardware from their carton. The upper duct is shipped inside the lower duct which is part of the ceiling template. B. Remove the upper duct from the ceiling template and locate it over the blower discharge.
9 INST ALLA TION INSTRUCTIONS TROL KIT A. If your installation included the optional electric heat kit, install it at this time. Follow the instructions with the heat package for its installation procedure. B. T erminate the 4-conductor control cable(s) protruding into the 14-1/4” x 14-1/4” (±1/8”) roof opening.
10 INST ALLA TION INSTRUCTIONS 8. SYSTEM CONFIGURA TION, RESET & CHECKOUT Nowthat thesystem isinstalled, itis necessaryto congurethe elec - tronics and check all operations. Refer to the Operating manual for a description of the air conditioner operation.
1 1 INST ALLA TION INSTRUCTIONS FIG. 16 T wo Zone Conguration FIG. 15 9. AIR BOX INST ALLA TION A. Remove return air grille from air box by pulling in on half- roundngercatches. B. Hold air box up to ceiling template and install three (3) #10 x 3/8” (C) screws at air box mounting point.
12 INST ALLA TION INSTRUCTIONS AIR CONDITIONING UNIT A. (4) 1/4” — #20 x 7” bolts B. (4) #8 x 5/8” long sharp point wood screws C. (7) #10 x 3/8” blunt point tapping screws D.
Ein wichtiger Punkt beim Kauf des Geräts Dometic BRISK AIR 579 SERIES (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Dometic BRISK AIR 579 SERIES noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Dometic BRISK AIR 579 SERIES - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Dometic BRISK AIR 579 SERIES reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Dometic BRISK AIR 579 SERIES erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Dometic BRISK AIR 579 SERIES besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Dometic BRISK AIR 579 SERIES verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Dometic BRISK AIR 579 SERIES. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Dometic BRISK AIR 579 SERIES gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.