LT-0229 (5/97) XR10/XR20 Command Processor Panels Installation Guide 10/26 Zone Burglary/Fire/Access Control Panels with Built-in Communicator 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 : http://www.
MODEL XR10/XR20 COMMAND PROCESSOR INST ALLA TION GUIDE FCC NOTICE This equipment generates and uses radio frequency energy and, if not installed and used properly in strict accordance with the manufacturer's instructions, may cause interference with radio and television reception.
TABLE OF CONTENTS Panel Specifications Power supply ........................................................................................ 1.1 Communication .................................................................................... 1.2 Panel zones .
TABLE OF CONTENTS Section Reset Jumpers J16 Description ......................................................................................... 14.1 Universal UL Burglary Specifications Introduction ..................................................
Page 1 Introduction 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide Panel Specifications 1.1 Power supply Transformer Input: 16.
Page 2 Introduction 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide 2.3 Before you begin Before installing the XR10/XR20, we recommend you read through the entire contents of this guide. Familiarize yourself with the features of the panel and the key points to remember during the installation.
Page 3 Introduction 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide System Components 3.1 Description The DMP XR10/XR20 system is made up of an alarm panel with built in communicator, an enclosure, a 16.5 VAC transformer, and a 12 VDC 6.
Page 4 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide Installation 4.1 Mounting the enclosure The metal enclosure for the XR10/XR20 must be mounted in a secure, dry place to protect the panel from damage due to tampering or the elements.
Page 5 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide 4.2 Mounting keypads Security Command keypads have removable covers that allow you to easily mount the base with keypad circuit board to a wall or other flat surface using the screw holes provided on each corner.
Page 6 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide 6.4 Discharge/recharge The XR10/XR20 battery charging circuit float charges at 13.9 VDC at a maximum current of 1.2 Amps using a 40VA transformer.
Page 7 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide Bell Output 7.1 Terminals 5 and 6 Nominal 12 VDC is supplied by terminal 5 on the panel to power alarm bells or horns. The output is rated for a maximum output of 1.
Page 8 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide 10.2 Operational parameters Each burglary protection zone detects three conditions: open, normal, and short. The parameters for each are listed below: Condition Resistance on zone Voltage on right terminal Open over 1300 ohms over 2.
Page 9 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide Annunciator Outputs 12.1 Description The four annunciator outputs can be programmed to indicate the activity of the panel's zones or conditions occurring on the system.
Page 10 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide 13.4 Ground start To configure the XR10/XR20 for ground start operation, you must install the appropriate ground start module and program one of the panel's available annunciator outputs for Ground Start operation.
Page 11 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide UNIVERSAL UL BURGLARY SPECIFICATIONS 15.1 Introduction The programming and installation specifications contained in this section must be completed when installing the XR10/XR20 panel in accordance with any of the UL burglary standards.
Page 12 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide UL 1610 and 1076 SPECIFICATIONS Central-Station and Proprietary Burglar-Alarm Units 17.1 Opening/Closing reports The Opening/Closing Reports option must be programmed as YES.
Page 13 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide 19.6 Mercantile Safe and Vault When the DMP Model 349A housing is used, the XR10/XR20 provides operation as a mercantile safe and vault alarm.
Page 14 Troubleshooting 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Installation Guide Problem Possible Cause Solution Security Command keypads display " SERVICE REQUIRED" J16 reset jumper is installed. Open or short on the green data wire to the keypad.
Ein wichtiger Punkt beim Kauf des Geräts DMP Electronics LT-0229 (5 97) (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie DMP Electronics LT-0229 (5 97) noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für DMP Electronics LT-0229 (5 97) - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von DMP Electronics LT-0229 (5 97) reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über DMP Electronics LT-0229 (5 97) erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon DMP Electronics LT-0229 (5 97) besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von DMP Electronics LT-0229 (5 97) verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit DMP Electronics LT-0229 (5 97). Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei DMP Electronics LT-0229 (5 97) gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.