Benutzeranleitung / Produktwartung SR52 des Produzenten Dito Dean
Zur Seite of 14
Price: $10.00 PRINTED IN T HE UNITED STATES For Service, Call (318) 865-1711 Dean, 8700 Line Av enue, PO Box 5100 0, Shreveport, Louisiana 71135-1000 Shipping Address: 8700 Line Av enue, Shreveport, L.
NOTICE This appliance is intended for profe ssional use only and is to be operated by qualified personnel o nly. A Frymaster/DEAN Factor y Authorized Service Cen ter (FASC) or other qualified profession al should perform installation, maintenance, and repairs.
SUPER RUNNER SERIES GAS FRYERS CHAPTER 1: INSTALLATION INSTRUCTIONS 1-1 1.1 Safety Information Before attempting to operate your unit, read the instructio ns in th is manual th oro ugh ly. Throu gho ut th is manua l you will find notatio ns enclosed i n double-b ordered boxes with the symbol .
SUPER RUNNER SERIES GAS FRYERS CHAPTER 1: INSTALLATION INSTRUCTIONS 1-2 For units equipped with leg s: Lift the unit and move it into its final position . Do not drag o r push the fryer into position. Doing so may damage th e legs. Level the un it front to back an d side to side.
SUPER RUNNER SERIES GAS FRYERS CHAPTER 1: INSTALLATION INSTRUCTIONS 1-3 AUSTRALIAN REQUIREMENTS: To be installed on a firm, level surface in accorda nce with AS 5601 / AG 601, local authority, gas, electricity, and any other releva nt statut ory regulat ions.
SUPER RUNNER SERIES GAS FRYERS CHAPTER 1: INSTALLATION INSTRUCTIONS 1-4 DANGER A manual shut-off valv e must be installed in the gas supply (serv ice) line upstream of this appliance and in a position where it can be reached qui ckly in the event of an emergency.
SUPER RUNNER SERIES GAS FRYERS CHAPTER 1: INSTALLATION INSTRUCTIONS 1-5 When conve rting from G20 (or G 25) gas to G3 1 propane ( or vice-versa) , the follo wing proced ures apply : ♦ Burner orifices and pilot orifice MUST be replaced.
SUPER RUNNER SERIES GAS FRYERS CHAPTER 1: INSTALLATION INSTRUCTIONS 1-6 Frypot Assembly Gas Valve Manifold Support Bracket Gas Burner See Detail A Pressure Test Spigot Orific e Temperature Control Gas Man if ol d Assembl y 1/2—3/4 Reducer Bushi ng Burner Gas Manifold Burner/Orifice Location Detail A Orific e 1.
SUPER RUNNER SERIES GAS FRYERS CHAPTER 2: OPERATION 2-1 2.1 Initial Startup Wash the unit and accessories thoroughly w ith hot, soapy water to remove a ny fi lm residue, dust or debris.
SUPER RUNNER SERIES GAS FRYERS CHAPTER 2: OPERATION 2-2 5. Fill the frypot with oil, shortening or water to th e bottom OIL LEVEL line scribed on the fry pot back.
SUPER RUNNER SERIES GAS FRYERS CHAPTER 2: OPERATION 2-3 DANGER "Dry-firing" the fry er will cause damage to the frypot and can caus e a fire. Always ensure that shortening, cooking oil or water covers the burner tubes before lighting the bur ners.
SUPER RUNNER SERIES GAS FRYERS CHAPTER 2: OPERATION 2-4 2.5 Wiring Diagram CE UNITS ONLY: WARNING DO NOT CON NEC T ANY EXTERNAL ELECTRICAL POW ER TO THIS UNIT THERMOPILE HONE YW ELL 807-3565 COAXIAL L.
THIS PAGE INTENTIONALLY LEFT BLANK.
Dean, 8700 Line Av enue, PO Box 5100 0, Shrev eport, Louisiana 71135-1000 Shipping Address: 8700 Line Av enue, Shreveport, Louisiana 71106 TEL 1-318-865-1711 FAX (Parts) 1-31 8-219 -7140 FAX (Tech Support) 1-318-219-7135 Price: $10.
Ein wichtiger Punkt beim Kauf des Geräts Dito Dean SR52 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Dito Dean SR52 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Dito Dean SR52 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Dito Dean SR52 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Dito Dean SR52 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Dito Dean SR52 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Dito Dean SR52 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Dito Dean SR52. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Dito Dean SR52 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.