Benutzeranleitung / Produktwartung ELCG 347 des Produzenten Desa Tech
Zur Seite of 16
1 HOMEOWNER’S INST ALLA TION AND OPERA TING INSTRUCTIONS COMFORT GLOW ELECTRIC LOG SET INSERT/ ELECTRIC LOG SET INSERT WITH FIREBACK MODEL #ELCG 240 / ELCG 347 Questions, problems, missing parts? Before returning to your retailer , call our customer service department at (814) 643-1775 8:30 a.
2 IMPORT ANT : Read all instructions and warnings carefully before starting Installation. F a ilure to follow these instructions may result in a possible electric shock, injury to persons, re hazard and will void the warranty . Please read the Installation & Operating Instructions before using this appliance.
3 Please read and understand this entire manual before attempting to assemble, operate or install the product. If you have any questions regarding the product, please call customer service at (814) 643-1775, 8:30 am to 5:00 pm EST , Monday – Friday .
4 GROUNDING PIN MET AL SCREW GROUNDING MEANS COVER OF GROUNDED OUTLET BOX ADAPTER (A) (B) (C) (D) Figure 1 GROUNDING PIN SAFETY INFORMA TION Electrical Connection Grounding Instructions A 15-Amp,120-V olt,60Hzcircuitwithaproperlygroundedoutletisrequired.
5 SAFETY INFORMA TION Remote Control PRODUCT DAMAGE MA Y OCCUR. Never attempt to disassemble or alter the product in any way not instructed by this manual. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and Industry Canada ICES-003.
6 INST ALLA TION INSTRUCTIONS Log Set Dimensions Α B C D Α B C D Model #ELCG 240 Model #ELCG 347 Ref. A B 8-3/4"(220mm) 1 1-1/2"(292mm) C 19-1/2"(495mm) 20"(508mm) D 13" (33.
7 INST ALLA TION INSTRUCTIONS Package Contents GH P B PA R T DESCRIPTION QUANTITY A Electric Log Set with Heater 1 B Infrared Remote Control 1 A.
8 INST ALLA TION INSTRUCTIONS • Intoanexistingreplace. • Onasolidoorupagainstasolidwall. • Intoanyopeningorenclosurethatmeetstheclearancestocombustibleslistedbelow .
9 OPERA TING INSTRUCTION Thelogsetconvenientlyfeaturesseparatecontrolsforameeffectandforheatercontrol. This allows you to operate the unit in two (2) different modes: • As a full-featured log set -bothameeffectandheaterareon.
10 2 3 1 The infrared remote control relies on a line of sight and must be pointed at the controls of the log set to work. The remote control unit has the controls required to turn ON/OFF both the main power and the heater . If you prefer to use the control buttons on the log set unit itself, they are on the lower right corner of the unit.
11 CARE AND MAINTENANCE Maintenance of Motors: Cleaning: Before attempting ANY maintenance: 1. T urn off power to the unit. 2. Unplug the power cord from outlet. 3. Let log set cool if it has been operating. Always disconnect the appliance from the main power supply and allow it to cool before any servicing operation.
12 Disconnect power before servicing. Anyelectricalre-wiringofthisappliancemustbedonebyaqualiedelectrician. This wiring must be done in accordance with local codes and/or in Canada with the current CSA C22.1 Canadian Electrical Code, and for US installations, the National Electrical Code ANSI/NFP A NO 70.
13 TROUBLESHOOTING If you have any questions regarding the product, please call customer service at (814) 643-1775 8:30 a.m. – 5:00 p .m. EST , Monday – Friday . Problem Possible Cause Corrective Action Log set does not operate; the ON/OFF power light on the control panel is not lit.
14 The manufacturer warrants that your new electric log set is free from manufacturing and material defects for a period of one year from date of purchase, subject to the following conditions and limitations. 1. This electric log set must be installed and operated at all times in accordance with the instructions furnished with the product.
15 REPLACEMENT P ARTS LIST For replacement parts, call our customer service department at (814) 643-1775, 8:30 a.m.- 5:00 p.m. EST , Monday – Friday .
16 Printed in China.
Ein wichtiger Punkt beim Kauf des Geräts Desa Tech ELCG 347 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Desa Tech ELCG 347 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Desa Tech ELCG 347 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Desa Tech ELCG 347 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Desa Tech ELCG 347 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Desa Tech ELCG 347 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Desa Tech ELCG 347 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Desa Tech ELCG 347. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Desa Tech ELCG 347 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.