Benutzeranleitung / Produktwartung Series E36SR des Produzenten Delta Electronics
Zur Seite of 15
FEATURES High efficiency: 89% @ 5V/ 15A Size: 58.4mm x 22.8mm x 9.2mm (2.30”x0.90”x0.36”) Industry standard pin out 18~75V extremely wide 4:1 input r ange Fixed frequency ope.
TECHNICAL SPECIFICA TIONS (T A =25°C, airflow rate=300 LFM, V in =48Vdc, nominal V out unless otherw ise noted.) PA R A M E T E R NOTES and CONDITIONS E36SR05015 (St andard) Min.
ELECTRICAL CHARACTERISTICS CUR VES Figure 1: Efficiency vs. load current for minimum, nominal, and maximum in put voltage at 25°C. DS_E36SR05015_010 42008 3 Figure 2: Power dissipation vs. load current for min imum, nominal, and max i mum input voltage at 25°C.
ELECTRICAL CHARACTERISTICS CUR VES Figure 4: T urn-on trans ient at full rated load current (CC mode) (5ms/div). Vin=48V .T op T rac e: V out, 2V/div; Bottom T race: ON/OFF input, 5V/div . Figure 5: T urn-on transient at zero load current (5ms/ div). Vin=48V .
ELECTRICAL CHARACTERISTICS CUR VES Figure 8: Output voltage response to step-change in load current (50%-25% of Io, max; di/dt = 0.1A/µs). Load cap: 10µF , tantalum cap acitor and 1 µF ceramic cap acitor. T op T race: Vout (100mV/div , 200us/div), Bottom T race: I out (5A/div).
ELECTRICAL CHARACTERISTICS CUR VES Figure 12: Input reflected ripple current, i s , through a 12µH source inductor at 48Vin and 15A output current (20 mA/ div , 2us/div). Strip Copper Vo(-) Vo(+) 10u 1u SCOPE RESISTIV E LOAD Figure 13: Output voltage noise and ripple measur ement test setup.
The input source must be insulated f rom the ac mains by reinforced or double insulation. The input terminals of the module are not operator accessible. If the metal baseplate is grounded , one Vi pin and one Vo pin shall also be grounded.
DS_E36SR05015_010 42008 8 FEA TURES DESCRIPTIONS Over-Current Protection The modules include an internal output over-curre nt protection circuit, which will endure current limiting for an unlimited duration during output overload. If the output current exceeds the OCP set point, the modul es will automatically shut down (hiccup mode).
FEA TURES DESCRIPTIONS (CON.) Output V oltage Adjustment (TRIM) To increase or decrea se the output voltage set poin t, the modules may be connected wit h an external resistor betwee n the TRIM pin and either the SENSE(+) or SENSE(-). The TRIM pin should be left open if this feature is not used.
DS_E36SR05015_010 42008 10 THERMAL CONSIDERA TIONS Thermal management is an important part of the syst em design. To ensure p roper, reliable operation, sufficie nt cooling of the power mod ule is needed over the entire temperature range of the modul e.
P I C K A N D P L A C E L O C A T I O N S U R F A C E - M O U N T T A P E & R E E L RECOMMENDED P AD LA YOUT (SMD) DS_E36SR05015_010 42008 11.
LEADED (Sn/Pb) PROCESS RECOMMEND TEMP . PROFILE T ime ( sec. ) Pre-h eat tem p. 140~180 ° C 60~120 sec. Peak tem p. 210~230 ° C 5sec . Ramp-up te mp. 0.5~3.0 ° C /sec . T emperature ( ° C ) 50 100 150 200 250 300 60 0 120 180 240 2nd Ramp-up temp.
MECHANICAL DRA WING Surface-mount module Through-hole module Pin No. Name Function 1 2 3 4 5 6 7 8 +Vin ON/OFF -Vin -V out -SENSE TRIM +SENSE +V out Positive input voltage Remote ON/OFF Negative input.
MECHANICAL DRA WING (WITH HEA TSPREADER) THROUGH-HOLE MODULE DS_E36SR05015_010 42008 14.
DS_E36SR05015_010 42008 15 P ART NUMBERING SYSTEM E 36 S R 050 15 N R F A T ype of Product Input V o ltage Number of Output s Product Series Output V o ltage Output Current ON/OFF Logic Pin Length/T ype Option Code E- Eighth Brick 36-18~75V S- Single R- Regular 050- 5.
Ein wichtiger Punkt beim Kauf des Geräts Delta Electronics Series E36SR (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Delta Electronics Series E36SR noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Delta Electronics Series E36SR - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Delta Electronics Series E36SR reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Delta Electronics Series E36SR erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Delta Electronics Series E36SR besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Delta Electronics Series E36SR verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Delta Electronics Series E36SR. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Delta Electronics Series E36SR gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.