FEA TURES High efficiency: 90% @5V/7A Industry standard 1x2 pin out Size: 33.0x24.4x8.55mm (1.30”x0.96”x0.34”) SMD and Through-hole versions Fixed frequency operation 2:1.
DS_S48SP05007_05222008 2 TECHNICAL SPECIFICA TIONS ( T A =25°C, airflow rate=300 LFM, V in =48Vdc, n ominal V out unle ss otherwise noted.) PA R A M E T E R NOTES and CONDITIONS S48SP05007 (St andard) Min.
DS_S48SP05007_05222008 3 ELECTRICAL CHARACTERISTICS CUR VES Figure 1: Ef ficiency vs. load current for minimum, nomi nal, and maximum in put voltage at 25°C Figure 2: Power dissipation vs. load current for min imum, nominal, and max imum input voltage at 25°C.
DS_S48SP05007_05222008 4 ELECTRICAL CHARACTERISTICS CUR VES For Negative Remote On/Off Logic Figure 4: T urn-on transient at full rated load current (5 ms/div). Vin=48V . T op T race: V out, 2V/div; Bottom T race: ON/OFF input, 2V/div Figure 5: T urn-on transient at zero load current (5 ms/ div).
DS_S48SP05007_05222008 5 ELECTRICAL CHARACTERISTICS CUR VES Figure 8: Output voltage response to step-change in load current (75%-50% of Io, max; di/dt = 0.1A/µs). Load cap: 10µF tantalum cap acitor and 1 µF ceramic capa citor. T op T race: V out (100mV/div , 50us/div), Bottom T race: Iout (2A/div).
DS_S48SP05007_05222008 6 ELECTRICAL CHARACTERISTICS CUR VES Figure 1 1: Input T erminal Ripple Current, i c , at full rated out put current and nominal i nput voltage with 12µH source impedance and 3.
DS_S48SP05007_05222008 7 DESIGN CONSIDERA TIONS Input Source Impedance The impedance of the input sou rce connecting to the DC/DC powe r modules will interact wit h the modules and affect the stability. A low ac-impedance input sou rce is recommended.
DS_S48SP05007_05222008 8 FEA TURES DESCRIPTIONS Over-Current Protection The modules include an internal output over-curre nt protection circuit, which will endure current limiting for an unlimited duration during output overload.
DS_S48SP05007_05222008 9 FEA TURES DESCRIPTIONS (CON.) Output V olt age Adjustment To increase or decrea se the output voltage set point, the modules may be connected wit h an external resistor between the TRIM pin and either the Vo (+) or Vo(-). The TRIM pin should be left open if this feature is not used.
DS_S48SP05007_05222008 10 THERMAL CONSIDERA TIONS Thermal management is an importa nt part of the system design. To ensure prop er, reliable operation, sufficient cooling of the power mod ule is needed over the entire temperature range of the modul e.
DS_S48SP05007_05222008 11 P I C K A N D P L A C E L O C A T I O N S U R F A C E - M O U N T T A P E & R E E L RECOMMENDED P AD LA YOUT (SMD).
DS_S48SP05007_05222008 12 LEADED (Sn/Pb) PROCESS RECOMMEND TEMP . PROFILE T ime ( sec. ) Pre-h eat tem p. 140~180 ° C 60~120 sec. Peak tem p. 210~230 ° C 5sec . Ramp-up te mp. 0.5~3.0 ° C /sec . T emperature ( ° C ) 50 100 150 200 250 300 60 0 120 180 240 2nd Ramp-up temp.
DS_S48SP05007_05222008 13 MECHANICAL DRA WING Surface-mount module Through-Hole module Pin No. Name Function 1 2 3 4 5 6 +Vin -Vin ON/OFF (Optional) -V out TRIM (Optional) +V out Positive input voltag.
DS_S48SP05007_05222008 14 P ART NUMBERING SYSTEM S 48 S P 050 07 N R F B Product Ty p e Input V oltage Number of Output s Product Series Output V oltage Output Current ON/OFF Logic Pin Length/T ype Op.
Ein wichtiger Punkt beim Kauf des Geräts Delta Electronics S48SP (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Delta Electronics S48SP noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Delta Electronics S48SP - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Delta Electronics S48SP reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Delta Electronics S48SP erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Delta Electronics S48SP besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Delta Electronics S48SP verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Delta Electronics S48SP. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Delta Electronics S48SP gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.