Benutzeranleitung / Produktwartung IPM24S0B0 des Produzenten Delta Electronics
Zur Seite of 14
Delphi Series IPM24S0B0, Non-Isolated, Integrated Point-of-Load Power Modules: 1 1V~36V input, 3.3~6.5V and 3A Output The Delphi Series IPM24S0B0 non-isolated, fully integrated Point-of-Load (POL) power module s, are the latest offerings from a world leader in power sy stems technology and manufa cturing -- Delta Electronics, Inc.
DS_IPM24S0B0_03202007 2 TECHNICAL SPECIFICA TIONS T A = 25°C, airflow rate = 300 LFM, V in = 24Vdc, nominal V out unless otherwise noted. P ARAMETER NOTES and CONDITIONS IPM24S0B0R/S03F A Min. T yp. Max. Units ABSOLUTE MAXIMUM RA TINGS Input V olt age (Continuous) 0 40 Vdc Operating T emperature Please refer to Fig.
DS_IPM24S0B0_03202007 3 ELECTRICAL CHARACTERISTICS CUR VES Figure 1: Converter efficiency vs. output current (3.30V output voltage) Figure 2: Converter efficiency vs. output current (4.0V output voltage) Figure 3: Converter efficiency vs. output current (5.
DS_IPM24S0B0_03202007 4 ELECTRICAL CHARACTERISTICS CUR VES Figure 7: Output ripple & noise at 12Vin, 4.0V/3A out Figure 8: Output ripple & noise at 24Vin, 4.0V/3A out Figure 9: Output ripple & noise at 12V in, 5.0V/3A out Figure 10: Output ripple & noise at 24Vin, 5.
DS_IPM24S0B0_03202007 5 ELECTRICAL CHARACTERISTICS CUR VES Figure 13: Power on waveform at 12vin, 3.3V/3A out with application of Vin Figure 14: Power on waveform at 12vin, 6.5V/3A out with application of Vin Figure 15: Power of f waveform at 12vin, 3.
DS_IPM24S0B0_03202007 6 ELECTRICAL CHARACTERISTICS CUR VES Figure 19: T urn on delay at 24vin, 3.3V/3A out with application of Vin Figure 20: T urn on delay at 24vin, 6.5V/3A out with application of Vin Figure 21: T ypical transient response to step loa d change at 0.
DS_IPM24S0 7 B0_03202007 TEST CONFIGURA TIONS V I (+) V I (-) BAT TERY 2 100uF Electr oly tic L TO O SC ILLOS CO PE Cera mi c 3.3uF Note: Input reflected-ripple current is measured with a simulated source induct ance. Current is measured at the input of the module.
DS_IPM24S0B0_03202007 8 DESIGN CONSIDERA TIONS Remote On/Off The IPM series powe r modules have an On/Of f control pin for output volt age remote On/Of f operation. The On/Off pin is an open coll ector/drain logic input sign al that is referenced to grou nd.
DS_IPM24S0B0_03202007 9 FEA TURES DESCRIPTIONS (CON.) Figure 28: T rim up Circuit configuration for programming output voltage using an external resistor Rtrim Lo ad Vout Tri m GND Figure 29: T rim do.
DS_IPM24S0B0_03202007 10 THERMAL CONSIDERA TIONS Thermal management is an importa nt part of the system design. To ensure prop er, reliable operation, suffici ent cooling of the power mod ule is needed over the entire temperature range of the modul e.
DS_IPM24S0B0_03202007 11 IPM24S (Standard) Output Current vs. Ambient Temperature and Air Velocity @ Vin=24V, Vout = 6.5V (Either Orientati on) 0 1 2 3 60 65 70 75 80 85 Ambient Temperature ( ℃ ) Output Current(A) Natural Convection 100LFM 200LFM Figure 33: Output current vs.
DS_IPM24S0B0_03202007 12 PICK AND PLACE LOCA TION A ll dimensions are in millimeter s (inches) SURF ACE- MOUNT T APE & REEL A ll dimensions are in millimete r s (inches) LEAD FREE PROCESS RECO MMEND TEMP . PROFILE Te Tim e 60 ~ 15 0 sec. Abo ve 2 17 0 C 20 ~ 40s ec.
DS_IPM24S0B0_03202007 13 Mechanical Drawing SMD P ACKAGE SIP P ACKAGE RECOMM END PWB PAD L AYOUT RECOMMEND PWB HO LE LAYOUT 12 3 45 12 3 4 5 76 12 3 45 : The copper pad is re commended to connec ote: All dimension are in millimeters (inches) standa rd dimension tolerance is ± 0.
DS_IPM24S0B0_03202007 14 P ART NUMBERING SYSTEM IPM 24 S 0B0 S 03 F A Product Family Input V oltage Number of Output s Output V olt age Package Output Current Option Code Integrated POL Module 1 1V ~ 36V S - Single 0B0 - programmable output 3.
Ein wichtiger Punkt beim Kauf des Geräts Delta Electronics IPM24S0B0 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Delta Electronics IPM24S0B0 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Delta Electronics IPM24S0B0 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Delta Electronics IPM24S0B0 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Delta Electronics IPM24S0B0 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Delta Electronics IPM24S0B0 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Delta Electronics IPM24S0B0 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Delta Electronics IPM24S0B0. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Delta Electronics IPM24S0B0 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.