Dayton Operating Instructions and Parts Manual 2 Dayton Portable Oil-Fir ed Heaters ® 3E358B and 3E359B Upper Shell Fuel Cap Thermostat Fuel T ank Power Cord Lower Shell Motor and Pump Assembly Hot A.
Dayton Operating Instructions and Parts Manual 3 ® Models 3E358B and 3E359B General Safety Information Make certain you read and understand all warnings. Keep these instructions for reference. They are your guide to safe and proper operation of this heater .
Dayton Operating Instructions and Parts Manual 4 Dayton Portable Oil-Fir ed Heaters ® 3E358B and 3E359B General Safety Information (Continued) THEOR Y OF OPERA TION THE FUEL SYSTEM The motor turns the fuel pump. The fuel pump pulls fuel from the fuel tank.
Dayton Operating Instructions and Parts Manual 5 ® Models 3E358B and 3E359B Follow the mini- mum fresh, outside air ventilation requir ements. If proper fresh, outside air ventilation is not provided, carbon monoxide poisoning can occur . Provide proper fr esh, outside air ventilation before running heater .
Dayton Operating Instructions and Parts Manual 6 Dayton Portable Oil-Fir ed Heaters ® 3E358B and 3E359B Operation (Continued) TO STOP HEA TER Never unplug heater while heater is running. Heater must go through purge cycle. The purge cycle cools the combustion chamber .
Dayton Operating Instructions and Parts Manual 7 ® Models 3E358B and 3E359B Figure 8 - Upper Shell Removal, Model 3E359B Upper Shell Maintenance Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur .
Dayton Operating Instructions and Parts Manual 8 Dayton Portable Oil-Fir ed Heaters ® 3E358B and 3E359B Fuel Filter Pump Cover Figure 13 - Fuel Pump and Filter Figure 15 - Location of Screw on Flange Clamp PUMP (Procedure if pump is binding) 1. Remove upper shell (See Figure 8, page 7).
Dayton Operating Instructions and Parts Manual 9 ® Models 3E358B and 3E359B Maintenance (Continued) Fuel Pump/ Filter 8. Inspect nozzle for damage. If damaged or clogged, replace nozzle. 9. Make sure plug is in place on burner head. 10. Replace nozzle into burner head and tighten firmly (175-200 inch- pounds).
Dayton Operating Instructions and Parts Manual 10 Dayton Portable Oil-Fir ed Heaters ® 3E358B and 3E359B PUMP PRESSURE ADJUSTMENT FOR HEA TERS WITH FUEL FIL TER INTER- NAL TO PUMP 1. Remove pressure gauge plug from fuel pump port marked “GAUGE.” 2.
Dayton Operating Instructions and Parts Manual 11 ® Models 3E358B and 3E359B Flush every 150-200 hours of operation or as needed Check for trash when filling fuel tank.
Dayton Operating Instructions and Parts Manual 12 Dayton Portable Oil-Fir ed Heaters ® 3E358B and 3E359B Wiring Diagram 1 3 2 FAN SWITCH 75 BA MOTOR RELAY WHITE RED ORANGE ORANGE RED BLACK WHITE BLAC.
Dayton Operating Instructions and Parts Manual 13 ® Models 3E358B and 3E359B T roubleshooting Chart Never service heater while it is plugged in, operating, or hot.
Dayton Operating Instructions and Parts Manual 14 Dayton Portable Oil-Fir ed Heaters ® 3E358B and 3E359B T roubleshooting Chart (Continued) Possible Cause(s) Corrective Action Symptom Heater will not ignite, but motor runs for a short period of time (Continued) 1.
Dayton Operating Instructions and Parts Manual 15 ® Models 3E358B and 3E359B T roubleshooting Chart (Continued) Possible Cause(s) Corrective Action Symptom Heater ignites, but flameout control shuts off heater after a short period of time (Continued) 4.
Dayton Operating Instructions and Parts Manual 16 Dayton Portable Oil-Fir ed Heaters ® 3E358B and 3E359B For Repair Parts, call 1-800-323-0620 24 hours a day – 365 days a year 8 11 9 (10 inside) 7 .
Dayton Operating Instructions and Parts Manual 17 ® Models 3E358B and 3E359B Repair Parts List Reference Number Description Part Number Qty . 1 Wiring cover 097492-03 1 2 5/16-24 x 5/16" Screw *.
Dayton Operating Instructions and Parts Manual 18 Dayton Portable Oil-Fir ed Heaters ® 3E358B and 3E359B For Repair Parts, call 1-800-323-0620 24 hours a day – 365 days a year Please provide follow.
Dayton Operating Instructions and Parts Manual 19 ® Models 3E358B and 3E359B Repair Parts List 3E358B and 3E359B Reference Number Description Part Number Qty .
Dayton Operating Instructions and Parts Manual 20 Dayton Portable Oil-Fir ed Heaters ® 3E358B and 3E359B For Repair Parts, call 1-800-323-0620 24 hours a day – 365 days a year 3E358B Figure 27 - Re.
Dayton Operating Instructions and Parts Manual 21 ® Models 3E358B and 3E359B 3E358B Repair Parts List Reference Number Description Part Number Quantity 1 Upper shell 108436-03 1 2 #10-16 x 1/2" .
Dayton Operating Instructions and Parts Manual 22 Dayton Portable Oil-Fir ed Heaters ® 3E358B and 3E359B Figure 28 - Repair Parts Illustration for Model 3E359B 1 2 2 3 4 5 13 6 7 45 46 8 9 10 11 13 1.
Dayton Operating Instructions and Parts Manual 23 ® Models 3E358B and 3E359B 3E359B Repair Parts List (*) Standard hardware item, available locally . (†) Not available as complete assembly .
Dayton Operating Instructions and Parts Manual 3E358B and 3E359B Manufactured for Dayton Electric Mfg. Co. Niles, Illinois 60714 U.S.A. 101422-01 Rev . G 07/02 ® LIMITED WARRANTY DAYTON ONE-YEAR LIMITED WARRANTY. Dayton ® Portable Oil-Fired heaters, Models covered in this manual, are warranted by Dayton Electric Mfg.
Ein wichtiger Punkt beim Kauf des Geräts Dayton 3E359B (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Dayton 3E359B noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Dayton 3E359B - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Dayton 3E359B reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Dayton 3E359B erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Dayton 3E359B besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Dayton 3E359B verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Dayton 3E359B. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Dayton 3E359B gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.