Benutzeranleitung / Produktwartung DS6300 des Produzenten Datalogic Scanning
Zur Seite of 39
DS6300 QUICK REFERENCE GUIDE.
CONTENTS DS6300-100-0 10 MASTER/SLA VE MODEL .............................................................................................. ............. 1 DS6300-100-0 11 PROFIBUS MODEL ................................................................
DS6300 MASTER/SLAVE MODEL 1 DS6300-100-010 MA STER/SLAVE MODEL Figure A Laser Beam Output W indow 1 Figure B Programming Keyp ad 1 Phase On LED (Yellow) 3 TX Data LED (Gree n) 2 Pow er On LE D (Red ) 4 LCD Display 5 Figure C Main/Aux.
DS6300 MASTER/SLAVE MODEL 2 SOFTWARE FEATURES ENVIRONMENTAL FEATURES Interleaved 2/5 Operating Readable Codes Code 39 sta ndard Temperature 0° to +40 °C (+32° to +104 °F) Codabar Code 128 Storage .
DS6300 MASTER/SLAVE MODEL 3 The details of the connector pins ar e indic ated in the following table: 25-pin D-Sub Connector Pi nout Pin Name Function Chassis - internally connecte d to GND 1 CHASSIS .
DS6300 MASTER/SLAVE MODEL 4 Connectivity: Point-to-Point Lay out * P.S. (Presence Sensor) connect ed to External Trigger/PS input. Pass Through Layout E N T < < E N T < < 1 2 Main Serial Interface A uxiliary Serial Interface * P.S. (Presence Sensor) connect ed to Externa l Trigger/PS input.
DS6300 MASTER/SLAVE MODEL 5 Multiplexer Layout E N T < < E N T < < 1 RS485 HD Main Interface * P.S. (Presence Sensor) connect ed to Externa l Trigger/PS input. RS232 Master/Slave Layout E N T < < E N T < < 1 Main Serial Interface 2 A uxiliary Serial Interface * P.
DS6300 MASTER/SLAVE MODEL 6 Local Lonw orks Network Small Synchronized Netw ork with 2 Readers * P.S. (Presence Sensor) connect ed to External Trigger/PS input.
DS6300 MASTER/SLAVE MODEL 7 Large Synchronize d Network * P.S. (Presence Sensor) connect ed to External Trigger/PS input. ** Encoder connected to ENC input.
DS6300 PROFIBUS MODEL 8 DS6300-100-011 PROFIBUS MODEL Figure A Laser Beam Output W indow 1 Figure B Programming Keyp ad 1 Phase On LED (Yellow) 3 TX Data LED (Gree n) 2 Pow er On LE D (Red ) 4 LCD Display 5 Figure C Prof ibus 9- pin Fema le Connect or (whi te) 1 Lonworks 9-pi n Female Connect or 2 Ma in/Aux.
DS6300 PROFIBUS MODEL 9 SOFTWARE FEATURES ENVIRONMENTAL FEATURES Interleaved 2/5 Operating Readable Codes Code 39 sta ndard Temperature 0° to +40 °C (+32 to +104 °F) Codabar Code 128 Storage Temper.
DS6300 PROFIBUS MODEL 10 26-pin D-Sub Connector Pi nout Pin Name Function Chassis - internally connecte d to GND 1 CHASSIS Cable shi eld connected to chassis 20 RXAU X Receive data o f auxiliary RS232.
DS6300 PROFIBUS MODEL 11 Connectivity: Point-to-Point Lay out * P.S. (Presence Sensor) connect ed to External T rigger/PS input. Pass Through Layout E N T < < E N T < < 1 2 Main Serial Interface A uxiliary Serial Interface * P.S. (Presence Sensor) connect ed to External T rigger/PS input.
DS6300 PROFIBUS MODEL 12 Local Lonw orks Network Fieldbus Small Synchronized Netw ork * P.S. (Presence Sensor) connect ed to External T rigger/PS input. ** C-BOX 100 modified to accept scanner p ower. *** T he Slave scanners are Master/Slave models, which allow Lonworks network propagation.
DS6300 ETHERNET MODEL 13 DS6300-100-012 ET HERNET MODEL Figure A Laser Beam Output W indow 1 Figure B Programming Keyp ad 1 Phase On LED (Yellow) 3 TX Data LED (Gree n) 2 Pow er On LE D (Red ) 4 LCD Display 5 Figure C RJ45 Modular Connect or f or Et herne t Int erf ace 1 Lonworks 9-pi n Female Connect or 2 Ma in/Aux.
DS6300 ETHERNET MODEL 14 SOFTWARE FEATURES ENVIRONMENTAL FEATURES Interleaved 2/5 Operating Readable Codes Code 39 sta ndard Temperature 0° to +40 °C (+32 to +104 °F) Codabar Code 128 Storage Tempe.
DS6300 ETHERNET MODEL 15 26-pin D-Sub Connector Pi nout Pin Name Function Chassis - internally connecte d to GND 1 CHASSIS Cable shield connected to ch assis 20 RXAU X Receiv e data of auxiliar y RS23.
DS6300 ETHERNET MODEL 16 Connectivity: Point-to-Point Lay out * P.S. (Presence Sensor) connect ed to External T rigger/PS input. Pass Through Layout E N T < < E N T < < 1 2 Main Serial Interface A uxiliary Serial Interface * P.S. (Presence Sensor) connect ed to External T rigger/PS input.
DS6300 ETHERNET MODEL 17 Local Lonw orks Network Fieldbus Small Synchronized Netw ork * P.S. (Presence Sensor) connect ed to External T rigger/PS input. ** C-BOX 100 modified to accept scanner p ower. *** T he Slave scanners are Master/Slave models, which allow Lonworks network propagation.
DS6300 DEVICENET MODEL 18 DS6300-100-015 D EVICENET MODEL Figure A Laser Beam Output W indow 1 Figure B Figure C Programming Keyp ad 1 Phase On LED (Yellow) 3 TX Data LED (Gree n) 2 Pow er On LE D (Red ) 4 LCD Display 5 Main/Aux.
DS6300 DEVICENET MODEL 19 SOFTWARE FEATURES ENVIRONMENTAL FEATURES Interleaved 2/5 Operating Readable Codes Code 39 sta ndard Temperature 0° to +40 °C (+32 to +104 °F) Codabar Code 128 Storage Temp.
DS6300 DEVICENET MODEL 20 The details of the connector pins ar e indic ated in the following table: 26-pin D-Sub Connector Pi nout Pin Name Function Chassis - internally connecte d to GND 1 CHASSIS Ca.
DS6300 DEVICENET MODEL 21 Connectivity: Point-to-Point Lay out * P.S. (Presence Sensor) connect ed to External T rigger/PS input. Pass Through Layout E N T < < E N T < < 1 2 Main Serial Interface A uxiliary Serial Interface * P.S. (Presence Sensor) connect ed to External T rigger/PS input.
DS6300 DEVICENET MODEL 22 Local Lonw orks Network Fieldbus Small Synchronized Netw ork * P.S. (Presence Sensor) connect ed to External T rigger/PS input. ** C-BOX 100 modified to accept scanner p ower. *** T he Slave scanners are Master/Slave models, which allow Lonworks network propagation.
DS6300 OSCILLATING MIRROR MODEL 23 DS6300-105-0XX OSCILLATING MIRROR MODEL Figure A Laser Beam Output W indow 1 Oscillating mirror models are used when coverage of a la rge reading area is re quired, mainly in picket fence applications. The DS6300 scanner mou nts a dedicated optic head with integr ated oscill ating mirror driven by a linear motor.
DS6300 OSCILLATING MIRROR MODEL 24 The mirror can be deflected up to 40°. Oscillation with resp ect to the output window median axis is as ymmetrical (see figure below).
COMMON FEATURES 25 COMMON FEATURES C-BOX 100 Pinout for DS6300: The table below gives the pi nout of the C-BOX 100 termi nal block connectors. Use this pinout when the DS6300 reader is connected in a .
COMMON FEATURES 26 Mechanical Installation: The DS6300 read er can be positi oned and installe d in the best way possible as a resul t of the Step-A-Head TM feature.
COMMON FEATURES 27 Typical Installations: Standard Installation The DS6300 scann er is mounted on the ST -237 106° mounti ng bracket which guarantees a built-in Skew angle ( S in the figure belo w) of 16° with respect to the frame plane (t ypically the Ske w angle should be bet ween 10° - 20°).
COMMON FEATURES 28 Focus Adjustment: The DS6300 provides a man ual adjustme nt of the optics to optimize the reading performance by cho osing the best focus between two extreme positions. The focus adju stment is continuous and not by step; thus, allo wing an optimum adjustment around the selected pos ition.
COMMON FEATURES 29 7) Use the ▲ ( up arrow) and ▼ (do wn arrow) key to select the “E xit” item, then press the ENT (enter) key to confirm. The scanner exits the Main Menu and returns to it s current operating mode. Focus Adjustment Screw NOTE The reader display shows the focus positio n only when the laser bea m is activated.
COMMON FEATURES 30 Minimum Code Height for ACR Reading (mm) 45° 30° Conveyor Speed (m/s) 0.5 1 1.5 2 2.5 3 0.5 1 1.5 2 2.5 3 0.25 8 9 11 13 15 17 5 7 8 10 11 13 0.30 8 10 12 14 16 18 6 7 9 10 12 13 0.33 9 11 13 14 16 18 6 8 9 11 12 14 0.38 10 11 13 15 17 19 7 8 10 11 13 14 0.
COMMON FEATURES 31 Reading Diagrams: In the following reading diagr ams (0,0) is the center of the laser beam output windo w. DS6300-100-0 XX – Resolution: 0.
COMMON FEATURES 32 Reading Diagrams: DS6300-100-0 XX – Resolution: 0. 38 mm/15 mils CONDITIONS Code = Inte rleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0.
COMMON FEATURES 33 Reading Diagrams: DS6300-105-0XX (Osc illating Mirror) – Resolutio n: 0.20 mm/8 m ils CONDITIONS Code = Interleaved 2/5 o r Code 39 PCS = 0.
COMMON FEATURES 34 Reading Diagrams: DS6300-105-0XX (Osc illating Mirror) – Resolutio n: 0.38 mm/15 mils CONDITIONS Code = Inte rleaved 2/5 or Code 39 PCS = 0.
COMMON FEATURES 35 User Interface: RS232 PC-side conn ections 1 5 9 6 9-pin male conne ctor 13 25 14 1 25-pin male c onnector Pin Name Pin Name 2 RX 3 RX 3 TX 2 T X 5 GND 7 GND 7 RTS 4 RTS 8 CTS 5 CTS.
COMMON FEATURES 36 Figure C Laser Safety Label 1 The scanner is classified as a Class 2 laser product accord ing to EN 60825-1 regulati ons and as a Class II laser product according to CDRH regulations. Disconnect the po wer supply when openin g the device during ma intenance or installatio n to avoid exposure to hazardous laser light.
DECLARATION OF CONFORMITY 07 Datalogic A utomation S.r.l. Via S. Vitalino 13 40012 - Lippo di Cal derara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät dec.
Ein wichtiger Punkt beim Kauf des Geräts Datalogic Scanning DS6300 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Datalogic Scanning DS6300 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Datalogic Scanning DS6300 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Datalogic Scanning DS6300 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Datalogic Scanning DS6300 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Datalogic Scanning DS6300 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Datalogic Scanning DS6300 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Datalogic Scanning DS6300. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Datalogic Scanning DS6300 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.