Benutzeranleitung / Produktwartung Heron D140 Laserout des Produzenten Datalogic
Zur Seite of 20
Heron™ D140 READERS QUICK REFERENCE GUIDE GUIDA RAPIDA GUIDE RAPIDE KURZANLEITUNG GUÍA RÁPIDA 820001212 (Rev. C) 9/07.
USING HERON™ SERIES READE RS UK Heron™ readers automatically s can barcodes at a dista nce . Simply aim and pull the trigger. Code scanning is performed along the light bar emitted from the reading window.
D Die Heron™ Lesepistol en lesen Strichcodes berührungslos . Es genügt auf den Code zu zielen und die Taste zu drücken. Der Code wird mittels eines Li chtbands gelesen, die das Gerät durch das Lesefenster verläßt und den gesamten Code durchqueren muss.
CONNECTIONS DISCONNECTING THE CABLE.
STAND INSTALLATION A B C UK The stand can be mounted by using self-tapping screws, double sided adhesive strips or rubber feet: A) mount the stand directly to the surface using the self-tapping screws; B) carefully clean the bottom surface of the stand and the table surface.
F Pour le montage du support il est possible également d’utiliser des vis filetées, des bandes adh ésives ou des petits patins en caoutchouc: A) utiliser des vis filetées pour le montage sur la surface d’appui; B) netto yer soigneusement la surface inférieure du support et la surface d’appui.
INSERTION IN TO STAND UK Pair the reader to the stand paying attention to insert the handle into the stand clip (see figure above). I Posizionare la pistola ne llo stand assicurandosi che il manico sia inserito nel fermo dello stand ste sso (vedi figura sopra).
ELECTRICAL CONNE CTIONS The Heron™ D140 scanner can be used with CAB 397 (coiled cable and 9-pin male connector) for direct connection to the DATAPLUS and DLD series decoders.
BEEPER/LED This scanner input drives the decoding LED, the Good Read Spot and the be eper in the scanner. The LED and Good Read Spot turn on when a positive current is applied to the pin. The beeper sound is obtained pulsating this current at a frequency of about 2 kHz.
BEEPER FUNCTIONING Heron™ Reader Start-Up Beeper 1 Meaning L L L L Parameters loaded correctly H H H H long tones Parameter loading error, reading or writing in the non-volatile memory H L H L Hardware error in EEPROM OFF No beeper performed when illuminator line is kept high at power on.
OPTIONAL CONFIGURATION PARA METERS UK To configure the reader with the optional parameters, follow the procedure (5 steps). In step 3 select only the parameters relative to your application. I Seguire la procedura per configurare il lettore con i parametri opzionali (5 passi).
Video Polarity Norma l : bar space whi te black barcode outp ut Video Polarity Inverted : bar space whi te black barcode output SCAN RATE 18 scan/sec ÌDI0`Î 36 scan/sec 72 scan/sec ÌDI1cÎ ÌDI.
BEEPER TONE Tone 1 ÌBH0Î Tone 2 Tone 3 ÌBH1_Î ÌBH2bÎ Tone 4 ÌBH3eÎ BEEPER LENGTH Long ÌBI0^Î Short ÌBI1aÎ BEEPER TYPE Monotone ÌBJ0`Î Bitonal ÌBJ1cÎ 4.
TECHNICAL FEATURES Heron™ D140 Electrical Features Power supply 5 Vdc ± 5% Consumption Operating Stand by 180 mA @ 5 Vdc 50 mA @ 5 Vdc CCD Scan Rate 256 scans/sec Max output scan rate 144 scans/sec.
READING DIAGRAM 0 5 10 15 20 25 30 35 -15 -10 -5 0 5 10 15 D140 - Reading Z ones (10° skew angle) (cm ) CODE 39 0.13 mm (5 mils) EA N13 M=1 0.33 mm (13 mils) CODE 39 0.
LED CLASS UK Class 1 LED product I Apparecchio LED classe 1 F Appareil à LED de classe 1 D LED Klasse 1 E Clase de LED 1 This product conforms to EN60825-1:2001. PATENTS This product is licensed under the following U.S. patent: 6,158,661 This product is covered by one or more of the following patents: U.
WARRANTY UK Datalogic warr anties this prod uct against de fects in workmanship an d materials, f or a period of 5 y ears from the date of s hipment, prov ided that th e product is operated und er normal and p roper conditi ons.
SERVICES AND SUPPORT UK Datalogic provides several services as well as technical support through its website. Log on to www.scanning.datal ogic.com and click on the Ulinks indicated for further information including: I Datalogic fornisce servizi e supporto tecnico tramite il suo sito web.
.
Datalogic Scanning, Inc. 959 Terry Street Eugene, OR 97402 07 dichiara che declares that the déclare qu e le bescheinigt, daß das Gerät declare que el Heron D1XX e tutti i suoi modelli and all its .
Ein wichtiger Punkt beim Kauf des Geräts Datalogic Heron D140 Laserout (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Datalogic Heron D140 Laserout noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Datalogic Heron D140 Laserout - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Datalogic Heron D140 Laserout reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Datalogic Heron D140 Laserout erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Datalogic Heron D140 Laserout besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Datalogic Heron D140 Laserout verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Datalogic Heron D140 Laserout. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Datalogic Heron D140 Laserout gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.