Benutzeranleitung / Produktwartung DX8200A-3010 des Produzenten Datalogic
Zur Seite of 139
DX8200A Reference Manual.
Datalogic Automation Srl Via Lavino, 265 40050 - Monte S. Pietro Bologna - Italy DX8200A Reference Manual Ed.: 10/2012 © 2005 – 2012 Datalogic Automation S.r.l. ALL RIGHTS RESERVED. Protected to the fullest extent under U.S. and international la ws.
iii CONTENTS REFERENCES ............................................................................................................ vi Reference Documentation ...........................................................................................
iv 4 CUSTOM CABLE ELECTRICAL CONNECTIONS ................................................... 33 4.1 Power Supply.............................................................................................................. 34 4.2 Main Serial Interface .
v 10.3.1 ASR Network Configuration ...................................................................................... 104 10.3.2 Scanner Replacement Procedure ............................................................................. 104 11 TROUBLESHOOTING .
vi REFERENCES REFERENCE DOCUMENTATION The documentation related to the DX8200A management is listed below: CBX100/CBX500 Installation Manuals PWR series power supply unit Installation Manuals .
vii COMPLIANCE ELECTRICAL SAFETY This product conforms to the applic able requirements cont ained in the European St andard for electrical safety EN-609 50 at the date of manufacture. WARNING This symbol refers to operations that must be performed by qualified personnel only.
viii Warning labels indicating exposure to laser light and the device classif ication are applied onto the body of the scanner ( Figure A): LASER LIGHT DO NOT ST ARE INTO BE AM CLASS 2 LASER PROD UCT .
ix CE COMPLIANCE Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment.
x GENERAL VIEW DX8200A Figure A - DX8200 A – Reading Windows Side Las er Beam O utput Wi ndows Las er Safety Label Mounti ng Sl ots 1 2 3 Mounti ng Refer ence Label 4 Figure B - DX8200 A Display and.
xi Figure C – Display a nd Keypad Panel Programming Keypad Power O n LED (Green) Phase On LED ( Yel lo w ) Encoder LED (Y ellow) 1 2 3 4 TX D ata LED (Green) Network LE D (R ed) LCD Dis pl ay 5 6 7 .
xii Figure G – Connect or Panel for Profibus Models Lonworks 17-pin mal e connector Lonworks 17-pin femal e connector Profi bus 9-pi n female conn ector 1 2 4 Serial inter face and I/ O 26-pi n conn.
xiii GUIDE TO INSTALLATION POINT-TO-POINT INSTA LLATION The following can be used as a checklist to verify all the necessary steps to complete installation of the DX8200A scanner. 1) Read all information in the section “Safety Regulations” at the beginning of this manual.
xiv MASTER/SLAVE LONWOR KS INSTALLATION The following can be used as a checklist to verify all the steps necessary to complete installation of the DX8200A scanner in a Master/Slave Lonworks network. 1) Read all information in the section “Safety Regulations” at the beginning of this manual.
xv 7) Send the configuration to the Master. 8) Perform the External Memory Backup Procedure for system backup purposes (see par. 10.2). For backward compatibility you can perform the ASR Network Configuration procedure f or system backup purposes (see par.
xvi.
INTRODUCTION 1 1 1 INTRODUCTION 1.1 PRODUCT DESCRIPTION The DX8200A scanner is a barcode reader complete with decoder designed to provide an innovative and high performance solution in omnidirectional reading applications by combining the following advanced technologies with Datalogic solid experience in the material handling sector.
DX8200A REFERENCE MANUAL 2 1 Feature Benefit ACR™ Advanced Code Reconstruction technology allows the reading of low aspect ratio labels placed anywhere on a parcel and enhances the readability of poorly printed or damaged codes.
INTRODUCTION 3 1 Feature Benefit Energy Saving A software parameter group which allows management of the energy saving feature. In particular, it allows turning on/off the motor and laser of all network scanners according to the selected digital input, encoder, or communication channel.
DX8200A REFERENCE MANUAL 4 1 1.5 KEYPAD AND DISPLAY The DX8200A keypad allows entering a menu for selection of one of the f ollowing functions: Welcome: shows the current software release and oper.
INTRODUCTION 5 1 1.5.2 Test Mode Test Mode is particularly advised during the installation phase, since it causes the reader to be continuously activated allowing verification of its reading features and its reading position with respect to the barcode.
DX8200A REFERENCE MANUAL 6 1 1.6 AUTO PACKTRACK™ CALIBR ATI ON FOR READING STATION USING SCANNER MENU 1.6.1 Auto PackTrack Conditions and Limits The Conditions and Limits for Auto PackTrack Calibra .
INTRODUCTION 7 1 1.6.2 Auto PackTrack Parameter Descriptions Menu Branch Default Note PackTrack Automatic Packtrack Calibration procedure for the Reading Station Version 2 Select the version number of the PCT-8000 pack Cal Type XYZ XYZ calibration is forced.
DX8200A REFERENCE MANUAL 8 1 Z Offset (if necessary): for packs that are elevat ed above th e conveyor surface (for example on tilt trays), this parameter sets an offset for the height o f a pack so that Z = 0 corresponds to the bottom of the pack. 1.
INTRODUCTION 9 1 Figure 1 - PCT-8000 First Run After elaborating the passage of t he parcel, the Master scanner again shows the status of each node (of each scanner of the cluster) and then the Continue or Stop screen. 6. Repeat steps 3 - 5 changing the PCT-8000 X position (i.
DX8200A REFERENCE MANUAL 10 1 7. At the last step in the sequence the display prompts to place a barcode label centered onto the physical X position (X Offset) on the conveyor. Press the ENT (enter) key to Continue. You have 2 minutes to read the code before the procedure ends automatically.
INTRODUCTION 11 1 1.7 ACCESSORIES The following accessories are available on request for DX8200A: Name Description Part Number Power Supplies PWR-120 J-box power unit 110/230 VAC 24 V 120 W 93ACC1530 .
DX8200A REFERENCE MANUAL 12 1 Name Description Part Number * Connection Boxes CBX100 Compact Connection Box 93A301067 CBX500 Modular Connection Box 93A301068 CBX800 Gateway Connection Box 93A301077 BM.
INSTALLATION 13 2 2 INSTALLATION To install the system follow the given procedure: 1. Select the mounting location for DX8200A; 2. Mount the DX8200A scanner; 3. Position the scanner with respect to the barcode; 4. Proceed with system electrical connection; 5.
DX8200A REFERENCE MANUAL 14 2 2.2 MECHANICAL MOUNTING 2.2.1 Mounting the Scanner DX8200A can be installed to operate in any po sition. There are 4 slots (dia. 8.5 mm) on the sides of the scanner for mounting. Th e d iag ram bel ow c an b e us ed f or i nst al la t io n; r ef er to p ar.
INSTALLATION 15 2 X-axis Reference Point Stop s The 2 washers and 2 spacers can be mounted to the Reading Station Frame using Bosch T- bolts and nuts to create 2 stops which can be used to facilitate DX8200A mounting and positioning. During initial mounting, affix the stops in appro ximation to the mountin g position.
DX8200A REFERENCE MANUAL 16 3 3 CBX ELECTRICAL CONNECTIONS Each scanner model has the following connectors: Scanner Model Connectors Standard 26-pin male serial interface and I/O connector 17-pin male.
CBX ELECTRICAL CONNECTIONS 17 3 The table below gives the pinout of the CBX100/500 terminal block connectors. Use this pinout when the DX8200A reader is connected by means of the CBX100/500: CBX100/50.
DX8200A REFERENCE MANUAL 18 3 NOTE To avoid electromagnetic interference when the scanner is connected to a CBX connection box, verify the jumper positions in the CBX as indicated in its Installation Manual.
CBX ELECTRICAL CONNECTIONS 19 3 3.2 MAIN SERIAL INTERFACE The main serial interface is compatible with the following electrical standards and the relative signals are available on the CBX spring clamp terminal blocks: RS232 RS485 full-duplex RS485 half-duplex The main interface type and the relative parameters (baud rate, data bits, etc.
DX8200A REFERENCE MANUAL 20 3 3.2.1 RS232 Interface The serial interface is used in this case for point-to-point connections; it handles communication with the host computer and allows both transmission of code data and the programming of the scanner.
CBX ELECTRICAL CONNECTIONS 21 3 3.2.2 RS485 Full-Duplex Interface The RS485 full-duplex (5 wires + shield) interface is used for non-polled communication protocols in point-to-point connections over lon ger distances (max 1200 m / 3940 ft) than those acceptable for RS232 communications or in electrically noisy environments.
DX8200A REFERENCE MANUAL 22 3 3.2.3 RS485 Half-Duplex Interface NOTE This interface is provided for backward compatibility. We recommend using the more efficient Lonworks network for Master/Slave or Multiplexer layouts. The RS485 half-duplex (3 wires + shield) interface is used for polled communication protocols.
CBX ELECTRICAL CONNECTIONS 23 3 #1 #0 (up to 31) Scanner Scanner Scanner Slave Slave Slave Main Interf ace RS232/RS485 HOST Multidrop GND Shield Multid rop - Multid rop + 1200 m Max Length Multidrop C.
DX8200A REFERENCE MANUAL 24 3 3.3 AUXILIARY RS232 INTERFACE The auxiliary serial interface is used exclusiv ely for RS232 point-to-point connections. It is principally used for scanner configuration from a laptop PC but is also available for LOCAL ECHO to a monitoring PC or for Pass through layouts.
CBX ELECTRICAL CONNECTIONS 25 3 3.4 INPUTS There are four optocoupled polarity insensitive inputs available on the scanner: Input 1 (External Trigger/PS), Input 2 (Encoder), Input 3 and 4 generic inputs.
DX8200A REFERENCE MANUAL 26 3 The driving logic of the input signals may be powered, for convenience, with the voltage supply at the CBX terminal block spring clamp s (V+) and (V-). In this case, however, the device is no longer electrically isolate d.
CBX ELECTRICAL CONNECTIONS 27 3 INPUT 2 (ENCODER) CONNECTIONS USING DX8200A POWER (r e d ) (wh i te ) O EK- 1 En co d e r ( P N P ) (b l a ck ) Figure 19 - OEK-1 Encoder PNP Us ing DX8200A Power P owe.
DX8200A REFERENCE MANUAL 28 3 NOTE Terminal pins I34B are common to both inputs 3 and 4 and therefore these inputs cannot be driven by opposite polarity de vices.
CBX ELECTRICAL CONNECTIONS 29 3 3.4.1 Code Verifier If the DX8200A is used as a Code Verifier, the verifier code can be configured in software through the Genius™ configuration program. However it is also possible to u se one of the inputs to trigger when the scanner should store a code read as the verifier code.
DX8200A REFERENCE MANUAL 30 3 The function of each output can be defined by t he user (No Read, Right, Wrong, etc.). Refer to the Genius™ Help On Line. The output signals are fully programmable being determined by the configured Activation/Deactivation events, Deactivation Timeout or a combination of the two.
CBX ELECTRICAL CONNECTIONS 31 3 OUTPUT 1 and 2 CONNECTIONS USING EXTERNAL POWER Ou t p u t D evi ce P owe r Refe renc e O utput S ig n a l Out p u t D evi ce Figure 29 - Open Emitter Ou tput Using Ext.
DX8200A REFERENCE MANUAL 32 3 OUTPUT 3 CONNECTIONS USING EXTERNAL POWER (CBX500 Only) Output Signal External Device Power or Ground Re ference Figure 33 - Ouput 3 Usin g External Power The command signals are filtered and generate a delay of about 50 µs for Output 1 and 2 and 1 ms for Output 3.
CUSTOM CABLE ELECTRICAL CONNE CTIONS 33 4 4 CUSTOM CABLE ELECTRICAL CONNECTIONS Each scanner model has the following connectors: Scanner Model Connectors Standard 26-pin male serial interface and I/O .
DX8200A REFERENCE MANUAL 34 4 The details of the connector pins are indicated in the following table: 10 19 1 18 9 26 Figure 34 - 26-pin Conne ctor DX8200A 26-pin D-sub Co nnector Pinout Pin Name Func.
CUSTOM CABLE ELECTRICAL CONNE CTIONS 35 4 Note that GND is internally connected to chassis. The cable shield is also connected to pin 1 - CHASSIS. DX 82 0 0 A US ER INT E RF ACE 23/ 25 GN D V- ( G ro .
DX8200A REFERENCE MANUAL 36 4 4.2.1 RS232 Interface The main serial interface is used for communication with the Host computer and allows both transmission of code data and configuring the reader. The overall maximum cable length should not exceed 15 m (50 ft).
CUSTOM CABLE ELECTRICAL CONNE CTIONS 37 4 4.2.2 RS485 Full-Duplex Interface The RS485 full-duplex (5 wires + shield) interface is used for non-polled communication protocols in point-to-point connections over lo nger distances than those acceptable for RS232 communications or in electrically noi sy environments.
DX8200A REFERENCE MANUAL 38 4 4.2.3 RS485 Half-Duplex Interface NOTE This interface is provided for backward compatibility. We recommend using the more efficient Lonworks network for Master/Slave or Multiplexer layouts. The RS485 half-duplex (3 wires + shield) interface can be used for p olled communication protocols.
CUSTOM CABLE ELECTRICAL CONNE CTIONS 39 4 Figure 41 – DX8200 A Multidrop Connection to a Multiplexe r.
DX8200A REFERENCE MANUAL 40 4 4.3 AUXILIARY INTERFACE The auxiliary serial interface is used exclusiv ely for RS232 point-to-point connections. It is principally used for scanner configuration from a laptop PC but is also available for LOCAL ECHO to a monitoring PC or for Pass through layouts.
CUSTOM CABLE ELECTRICAL CONNE CTIONS 41 4 the same value which usually corresponds to 5 ms when us ing a photoelectric sensor, while I2 is set to 500 s when this input is used for the Encoder.
DX8200A REFERENCE MANUAL 42 4 INPUT 1 - 2 CONNECTIONS USING EXTERNAL POWE R E X T E RN AL T R I G G E R / E N C O D E R DX 8 20 0 A + 5 V A/B Vext B/ A V ~ ~ + - Gr ou nd Figure 45 – PNP Command Inp.
CUSTOM CABLE ELECTRICAL CONNE CTIONS 43 4 INPUT 3 - 4 CONNECTIONS USING EXTERNAL POWE R E XTE R N A L DE V I CE D X8 200 A I3A Vext G r o un d V + 5 V ~ ~ + - Gro un d V I4A + 5V ~ ~ + - I34B Vext Figure 48 - I3/I4 PNP Input Command using External Power 4.
DX8200A REFERENCE MANUAL 44 4 Output 3 has different electrical features. It is a bi-directional solid state relay with built-in current limit protection. Output 3 Maximum Voltage ± 100 V ( Ve xt only ) Collector Current (pulse) 300 mA Max. at 25°C (Ambient temperature) 240 mA Max.
CUSTOM CABLE ELECTRICAL CONNE CTIONS 45 4 DX820 0A USER I N T ER F AC E V ex t 100 V dc m ax A/ B B/ A Figure 50 – Outp ut 3 Interface The command signals are filtered and generate a delay of about 50 µs for Output 1 and 2 and 1 ms for Output 3. 4.
DX8200A REFERENCE MANUAL 46 5 5 LONWORKS CO NNECTIONS A1 A2 1 15 scanner side external view A1 A2 1 15 OUTPUT (female) INPUT (male) Figure 51 - Lonw orks INPUT/OUTPUT Connectors The following pinout is valid for the INPUT connector as well as for the OUTPUT connector.
LONWORKS CONNECTIO NS 47 5 5.1 NETWORK TERMINATION When building a Lonworks system the network must be properly terminated by positioning the BTK-8102 Lonworks terminator in the DX8200A master reader and the BTK-8100 Lonworks bus return in the last DX8200A slave reader.
DX8200A REFERENCE MANUAL 48 5 5.2 LONWORKS INTERFACE The Lonworks network is used for both input and output connection to build a multi-sided or omni-station system connecting several readers.
LONWORKS CONNECTIO NS 49 5 The following diagrams represent different network terminations using either the BTK-8102 Lonworks terminator or the BTK-8100 bus return.
DX8200A REFERENCE MANUAL 50 6 6 FIELDBUS CONNECTIO NS 6.1 ETHERNET INTERFACE This connector is only available for DX8200A Ethernet models and allows the Ethernet connection between the host and the reader.
FIELDBUS CONNECTIONS 51 6 6.2 ETHERNET INTERFACE (OLDER MODELS) The RJ Industrial modular connector is only available for older DX8200A Ethernet models and allows the Ethernet connection between the host and the reader.
DX8200A REFERENCE MANUAL 52 6 The Ethernet interface can be used for TCP/IP communication with a remote or local host computer by connecting the scanner to a LAN.
FIELDBUS CONNECTIONS 53 6 6.3 DEVICENET INTERFACE The 5-pin male connector is only available in the DX8200A DeviceNet model and allows connection between the host and the reader: 1 3 2 4 5 Figure 64 -.
DX8200A REFERENCE MANUAL 54 6 6.4 PROFIBUS INTERFACE The 9-pin Profibus female connector (white) is only available in the DX 8200A Profibus model and allows connection between the host and the reader:.
TYPICAL LAYOUTS 55 7 7 TYPICAL LAYOUTS DX8200A scanners are mainly designed to work together on a high performance Lonworks sub-network to create multi-sided and omnidirectional reading stations that can interface with Serial or Fieldbus Host networks.
DX8200A REFERENCE MANUAL 56 7 CAUTION For DX8200A Lonworks Network layouts, power is always propagated through the 17-pin scanner connectors. A specific jum per setting is required in CBXs to pass scanner power to the presence sensor, encoder, etc. 7.
TYPICAL LAYOUTS 57 7 The following image shows a system consisting of five readers where the external signals (trigger/PS, encoder, serial to host, etc.
DX8200A REFERENCE MANUAL 58 7 7.1.2 Large Synchronized N etwork When building a large local Lonworks network (more than 10 scanners), an SC6000 Controller must be used together with a PWO power supply/junction box unit. In this case the SC6000 unit acts as the system master and is connected to the host through one of its interfaces.
TYPICAL LAYOUTS 59 7 Figure 69 – Exampl e Large Synchron ized Network Readi ng Station Here are a few helpful hints which can improve station performance and reduce installation time: 1. Scanner distribution should alternate between odd and even branches so that the station guarantees 50% reading on all side s.
DX8200A REFERENCE MANUAL 60 7 7.1.3 Redundant System For large local Lonworks networks, a redundant system can per configured in which two SC6000 Controllers are used together with their respective PWO power supply/jun ction box units. The scanners are distributed equally between the PWO units.
TYPICAL LAYOUTS 61 7 Figure 71 – Exam ple Redundant Reading Sta tion Conv eyor SC6000 Working A H G C D B E F PWO SC6000 Protecting PWO.
DX8200A REFERENCE MANUAL 62 7 7.1.4 Multidata Network In this layout, one master and up to 7 DX8200A slave readers have their own P.S. and therefore multiple reading phases. Each P.S. is connected through a CBX100, which in turn is connected to its relative scanner through a CAB-F0x cable.
TYPICAL LAYOUTS 63 7 7.1.5 Fieldbus Networks The Fieldbus models (Ethernet, Profibus, DeviceNet) offer connectivity without any converter or adapter needed.
DX8200A REFERENCE MANUAL 64 7 NOTE To interface DX8200A scanners to other Host types (Fieldbus and n on- Fieldbus), use the CBX800 Gateway with Host Interface Modules. * P.S. (Presence Sensor) connected to Input 1 (External Trigg er/PS) input. ** CBX800 jumper set to accept scanner power.
SOFTWARE CONFIGURA TION 65 8 8 SOFTWARE CO NFIGURATION 8.1 GENIUS™ INSTALLATION Genius ™ is a new Datalogic scanner configurat ion tool providing several important advantages: Wizard approach .
DX8200A REFERENCE MANUAL 66 8 After defining the parameter values the following window appears allowing to complete the reader configuration as follows: - Saving the configuration to disk; - Switching to Advanced mode; - Sending the configuration to the scanner.
SOFTWARE CONFIGURA TION 67 8 On Line Operating Mode Figure 78 - On Line Mode Se lection This operating mode causes the reader to be connected to an external Presence Sensor using I1A and I1B (External Trigger/PS) inputs. During the active phase of the presence sensor, the DX8200A reader tries to acquire and correctly decode the code.
DX8200A REFERENCE MANUAL 68 8 8.2.2 Genius™ Network Setup Through Master Network Setup allows configuring your Local Lonworks Network through the Master using Genius™.
SOFTWARE CONFIGURA TION 69 8 The following dialog box appears asking whether to send the configuration to the Local Device or not: 2. Click the "Yes" button, then click on the icon available on the Toolbar to make the “Devices” area appear next to the Parameter Explorer window.
DX8200A REFERENCE MANUAL 70 8 3. Then, proceed with the network setup by using one of the icons available on the Tool Bar according to the procedure to follow: = Net-Autoset procedure = Network Wizard.
SOFTWARE CONFIGURA TION 71 8 Network Wizard Before performing this procedure, a Lonworks address must be assigned to each slave scanner. The most practical method is through the Net-Autoset procedure. See par. 8.2.3 for alternative address assignment methods.
DX8200A REFERENCE MANUAL 72 8 2. If desired, select a slave scanner within the "Current Devices" area and click on the icon (or select the "Show Device" option from the right-click.
SOFTWARE CONFIGURA TION 73 8 8.2.3 Alternative Sla ve Address Assignment As alternatives to Network Setup through the Master, each Slave scanner can be assigned an address through the following method.
DX8200A REFERENCE MANUAL 74 8 8.3.1 Genius™ Shortcuts fo r Network Configuration Once the Network Setup is structured in Genius and the Master is configured, there are a few shortcuts that Genius offers to quickly configure the slaves.
SOFTWARE CONFIGURA TION 75 8 It is possible to Paste, Send or Load configurations simultaneously 1 to a selected number of devices by clicking the relative device check box and executing the desir ed command. These same functions 2 can be selected from the Edit menu as well.
DX8200A REFERENCE MANUAL 76 8 8.4 PARAMETE R DEFAULT VA LUES The following table contains the list of the factor y default settings for the DX8200A. Genius™ also allows checking the parameter defaul.
SOFTWARE CONFIGURA TION 77 8 Parameter Default Setting Reading System Layout Device Assignment Alone Modify&Backup Lon Slave Configuration Disabled (unchecked) Enable A.
DX8200A REFERENCE MANUAL 78 8 Parameter Default Setting Main Serial Port Parameters Main Port Communication Mode Standard Main Port Electrical Interface RS232 Handshake None Baud Rate 9600 Parity None.
SOFTWARE CONFIGURA TION 79 8 Parameter Default Setting Output 3 Line State Normally Open Activation Event None Alternative Activation Event None Deactivation Event None Alternative Deactivation Event .
DX8200A REFERENCE MANUAL 80 8 Parameter Default Setting User Information Section End User Name Empty Device Name Empty Line Name Empty.
READING FEATURES 81 9 9 READING FEATURES 9.1 ADVANCED CODE RECONSTRUCTION (ACR™ 4) The traditional way of barcode reading could be called “Linear Reading”.
DX8200A REFERENCE MANUAL 82 9 The decoder will be able to read th e label with a tilt angle between + max and - max as shown in the following figure: Conveyor Laser Beam No Read No Read - .
READING FEATURES 83 9 Figure 88 – PackTra ck™ System Layout Working in PackTrack™ mode requires the presence of an encoder and a prese nce sensor to track the moving packs. For correct functioning, t he PackTrack™ operating mode requires a calibration just after the installation of the scanners.
DX8200A REFERENCE MANUAL 84 9 coordinates of its central point, independently from which scanner is reading it. This can be verified using the Test mode in the SPY PackTrack Calibration dialog box (see par.
READING FEATURES 85 9 Auto PackTrack Parameter Descriptions By means of the software tool DLAPC, it is possible to perform the Auto PackTrack setup procedure for PackTrack™ and Continuous Operating Mode applications.
DX8200A REFERENCE MANUAL 86 9 Calibration Type : XYZ calibration with Absolute X position is forced. The coordinates for the three axes are calibrated.
READING FEATURES 87 9 Auto PackTrack Setup 1. Click on the Start button and follow the instructions given in the Auto PackTrack procedure window. The first message is sent to the slaves and thei r status is shown in the synoptic buttons at the top of the window.
DX8200A REFERENCE MANUAL 88 9 To run each instruction press the Next button. The procedure repeats the steps asking to change the PCT-8000 X position (i.e. always before the PS Line (reference point) and parallel to a conveyor edge but changing to the left-hand edge and/or to the center of the conveyor), until the procedure terminates.
READING FEATURES 89 9 3. The Absolute X coordinate requires placing the barcode label centered onto the physical X position (X Offset) on the conveyor (previously set in the dialog box), you have 2 minutes to read the code before the procedure ends automatically.
DX8200A REFERENCE MANUAL 90 9 Auto PackTrack Report The Auto PackTrack Report file can be downloaded from the Master scanner RAM by using the Tools>File transfer… menu in Genius™.
READING FEATURES 91 9 The last section summarizes the calibration status of each scanner. ------------- ------------- ------------ SCANNERS STATE SUMMARY ------------- ------------- ------------ Scann.
DX8200A REFERENCE MANUAL 92 9 Once the Spy window has been opened, select the “PackTrack™ Calibration” option from the Tools menu: Figure 91 – Selectin g PackTrack™ Calibra tion Option The following window will open: Figure 92 – PackTrack™ Cal ibration Window Set the PS Offset and Direction parameters.
READING FEATURES 93 9 DX8200A Scanner Di rection 90° DX8200A Scanner Di rection 180° (Reverse) DX8200A Scanner Di rection 270° PS Offset X Z Y Conveyor Direction Top View Conveyor Direction Top Vie.
DX8200A REFERENCE MANUAL 94 9 9.2.3 Overwriting PackTrack ™ Calibration for DX8200A Only necessary for special circumstances , it is possible to overwrite the factory scanner calibration by clicking on the “Calibrate DX” button shown in the figure ab ove.
READING FEATURES 95 9 For DX scanners the zero coordinate references are located on the scanner. Figure 95 – DX8200A Coordinate Reference Point Figure 96 – DX8200 A Scan Legs To overwrite the factory scanner calibration, follow the procedure below for Leg 1: 1.
DX8200A REFERENCE MANUAL 96 9 NOTE In the vast majority of system s the x and z data are not necessary. For these cases set x = 0, z= 0 during the calibration procedure. 3. Press the Calibrate button for Position 1 to start the calibration. 4. Repeat the same procedure for Position 2 and Position 3.
READING FEATURES 97 9 9.3.1 Reading Conditions ANSI Grade B minimum 500 scans/sec per leg The following tables describe the requirements for standard applications. Minimum Code Height for Omnidirectional Reading (mm) Conveyor Speed (m/s) 0.5 1 1.
DX8200A REFERENCE MANUAL 98 9 Minimum Code Height for Omnidirectional Reading (mm) Conveyor Speed (m/s) 0.5 1 1.5 2 2.5 3 0.25 8 10 12 14 16 18 0.30 9 11 13 15 17 19 0.33 9 11 13 15 18 20 0.38 10 12 14 16 18 20 0.50 13 14 16 18 20 22 0.72 17 18 19 21 24 26 Codabar Code Resolution (mm) 1.
READING FEATURES 99 9 9.4 READING DIAGRAMS DX8200A-3X3X (0.25 mm/10 mils) The diagram shows an average reading area obtained considering different barco de types of variable quality.
DX8200A REFERENCE MANUAL 100 9 DX8200A-3X2X (0.30 mm/12 mils) The diagram shows an average reading area obtained considering different barco de types of variable quality.
READING FEATURES 101 9 DX8200A-3X1X (0.38 mm/15 mils) The diagram shows an average reading area obtained considering different barco de types of variable quality.
DX8200A REFERENCE MANUAL 102 9 DX8200A-3X1X (0.50 mm/20 mils) The diagram shows an average reading area obtained considering different barco de types of variable quality.
MAINTENANCE 103 10 10 MAINTENANCE 10.1 CLEANING Clean the laser beam output windows periodically for correct operation of the scanner (see Figure A in chapter “General View”). Dust, dirt, et c. on the window may alter the reading performance. Repeat the operation frequently in particularly dirty environments.
DX8200A REFERENCE MANUAL 104 10 The ASR procedure is principally used for PackTrack™ configurations, but it restor es only a part of the system parameters: commo n slave parameters (Code Selection and Reconstruction) plus each single slave PackTrack™ calibration.
TROUBLESHOOTING 105 11 11 TROUBLESHOOTING NOTE Before contacting your local Datalogic off ice or Datalogic Partner or ARC, it is suggested to save the device configuration to a *.ddc file by m eans of the Genius™ software configuration program and check the device exact model and serial number.
DX8200A REFERENCE MANUAL 106 11 TROUBLESHOOTING GUIDE Problem Suggestion On Line Mode and Serial On Line Mode: the reader does not respond correctly to the expected external signal end. In the Genius™ software configuration program select the OPERATING MODES folder and check the “Reading Phase Timeout” parameterization.
TROUBLESHOOTING 107 11 TROUBLESHOOTING GUIDE Problem Suggestion Communication: the scanner “Network” LED is not lit. If the LED is OFF, check the connections between the DX8200A slaves a nd the SC6000 or DX8200A master. If the error persists, co ntact your Datalogic distributor.
DX8200A REFERENCE MANUAL 108 12 12 TECHNICAL FEATURES ELECTRICAL FEATURES VAC models VDC models Supply voltage 110 to 240 Vac 20 to 30 Vdc Power consumption 30 VA typical 24 W typical 0.
TECHNICAL FEATURES 109 12 SOFTWARE FEATURES Readable Codes In terle av ed 2 /5 Code 39 Standard Codabar Code 128 GS1-128 (ex EAN 128) Code 93 (standard a nd full ASCII) EAN /UPC (including Ad d-on 2 a.
DX8200A REFERENCE MANUAL 110 A A ALTERNATIVE LAYOUTS POINT-TO-POINT Using a Point-to-Point layout, the data is transmitted on the Main interface as well as on the Auxiliary interface. The Main interface can be selected for RS232 or RS485 full-duplex communications.
ALTERNATIVE LAYOUTS 111 A In general, for all point-to-point layouts, DX 8200A Vac models can substitute the Vdc model and therefore eliminate the PWR power supply. This requires that the CBX100/CBX500 must have the correct Power Source jumper setting to accept scanner power for the P.
DX8200A REFERENCE MANUAL 112 A ID-NET™ GATEWAY The CBX800 Gateway can be used to integrate a DX8200A reader into a high speed ID- NET™ network consisting of different scanners not provided with a Lonworks interfac e. In this case the DX8200A uses its main RS232/RS485 interface to communicate with the CBX800.
ALTERNATIVE LAYOUTS 113 A PASS THROUGH When Pass Through is activated on the Auxiliary interface, the DX8200A reader can be integrated in a network consisting of different scanners not provided with a Lonworks interface. This connection mode allows two or more devices to be connected to a single external serial interface.
DX8200A REFERENCE MANUAL 114 A 1 2 Main Seri al Interface A uxiliar y Ser ial In ter fa ce * P.S. (Presence Sensor) connected to Input 1 (External Trigger/PS) input.
ALTERNATIVE LAYOUTS 115 A Figure 104 – RS232 Maste r/Slave for DX8200 A Standard Model s Figure 105 – RS232 Master/Slave for DX8200A Fieldbus Models 3 Main Serial Interface (RS232 only) Au.
DX8200A REFERENCE MANUAL 116 A MULTIPLEXER The Multiplexer connection is used to integrate a DX8200A slave reader in a Multidrop network consisting of different scanners not provided with a Lonworks int erface. Each scanner is connected to a Multiplexer (MX4000) with the RS485 half-duplex main interface.
117 GLOSSARY ACR™ 4 Each version of the base has the powerful cod e reconstruction technology (ACR™ 4). The new fourth generation ACR™ considerably increases the code reconstruction reading capability in the case of damaged or very tilted barcodes.
118 LED (Light Emitting Diode) A low power electronic device that can serve a s a visible or near infrared light source when voltage is applied continuously or in pulses. It is commonly used as an indicator light and uses less power than an incandescent light bulb but more than a Liquid Crystal Display (LCD).
119 Trigger Signal A signal, typically provided by a photoelectric s ensor or proximity switch, which informs the scanner of the presence of an object within its re ading zone. UPC Acronym for Universal Product Code. The standard barcode type for retail food packaging in the United States.
120 INDEX A Accessories, 11 ACR™ 4, 81 Alternative Layouts, 110 Auto PackTrack Conditions and Limits, 6 Parameter Descriptions, 7 Setup Procedure, 8 Setup using Keypad, 5 Auto PackTrack™ Calibrati.
121 Reference Documentation, vi RS232 Interface, 20, 36 RS485 Full-Duplex, 21, 37 RS485 Half-Duplex, 22, 38 S Scanner Assignment using Keypad, 4 Scanner Direction, 92 Scanner Replacement, 103 Services.
DECLA RA T ION OF CONFORMIT Y EC-027 Rev.: 6 Pag.: 1 di 1 Datalogic Aut omation S.r.l. Via Lavi no 265 40050 Monte San Pi etro Bologna - Italy ww w.automation.
www .automation.datalogic.com.
Ein wichtiger Punkt beim Kauf des Geräts Datalogic DX8200A-3010 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Datalogic DX8200A-3010 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Datalogic DX8200A-3010 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Datalogic DX8200A-3010 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Datalogic DX8200A-3010 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Datalogic DX8200A-3010 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Datalogic DX8200A-3010 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Datalogic DX8200A-3010. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Datalogic DX8200A-3010 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.