Benutzeranleitung / Produktwartung DS6400-105-012 des Produzenten Datalogic
Zur Seite of 159
DS6400 Reference Manual.
Datalogic Automation Srl Via Lavino, 265 40050 - Monte S. Pietro Bologna - Italy DS6400 Reference Manual Ed.: 10/2012 © 2003 – 2012 Datalogic Automation S.r.l. ALL RIGHTS RESERVED. Protected to the fullest extent under U.S. and international la ws.
iii CONTENTS REFERENCES ............................................................................................................ vi Reference Documentation ...........................................................................................
iv 3.4.1 Code Verifier ............................................................................................................... 37 3.5 Outputs .....................................................................................................
v 9.4.1 Reading Conditions .................................................................................................. 100 9.5 Reading Diagrams ....................................................................................................
vi REFERENCES REFERENCE DOCUMENTATION The documentation related to the DS6400 management is listed below: CBX100/CBX500 Installation Manuals PWR series power supply unit Installation Manuals .
vii COMPLIANCE ELECTRICAL SAFETY This product conforms to the applic able requirements cont ained in the European St andard for electrical safety EN-609 50 at the date of manufacture. WARNING This symbol refers to operations that must be performed by qualified personnel only.
viii Warning labels indicating exposure to laser light and the device classif ication are applied onto the body of the scanner ( Figure A): AVOID EXP OSURE LASER R ADIATION IS EMITTED FROM THIS APERT .
ix CE COMPLIANCE Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment.
x GENERAL VIEW DS6400 Figure A - DS6400 Laser Saf ety Label W ar ning and Device Class Label Identif ication Label Connector Panel Display and Key pad Panel Laser Beam Output W indow 1 3 7 6 5 2 Servi.
xi DS6400 Figure B - DS6400 Oscillating Mirror Version Laser Safety Label 1 Laser Beam Output W indow 2 Figure C – Display a nd Keypad Panel Programming Keypad Phase On LED TX Da ta LE D Pow er On L.
xii Figure D – Connector Pane l for Master/Slave Mode ls Main/Aux. Interf ace 25-p in D-Sub male connec tor 1 Lonworks 9-pin m ale connector 2 Lonworks 9- pin f emale connector 3 Figure E – Connector Pane l for Ethernet Models M ai n/ A ux .
xiii Figure F – Connector Pa nel for DeviceNet Models Main/Aux. Interf ace 26-p in D-Sub male connec tor 1 DeviceNet 5-pin male connect or 2 Lonworks 9- pin f emale connector 3 Figure G – Connect or Panel for Profibus Models Main/Aux.
xiv GUIDE TO INSTALLATION POINT-TO-POINT INSTA LLATION The following can be used as a checklist to verify all the necessary steps to complete installation of the DS6400 scanner. 1) Read all information in the section “Compliance” at the beginning of this manual.
xv MASTER/SLAVE LONWOR KS INSTALLATION The following can be used as a checklist to verify all the steps necessary to complete installation of the DS6400 scanner in a Master/Slave Lonworks network. 1) Read all information in the section “Compliance” at the beginning of this manual.
xvi 7) Send the configuration to the Master. 8) Perform the External Memory Backup Procedure for system backup purposes (see par. 10.2). For backward compatibility you can perform the ASR Network Configuration procedure f or system backup purposes (see par.
INTRODUCTION 1 1 1 INTRODUCTION 1.1 PRODUCT DESCRIPTION The DS6400 is a high performance laser scanner in a complete range of industrial bar code readers offering an innovative and modular solution in terms of reading performance, connectivity and maintenance, in addition to a completely new hardware and software platform.
DS6400 REFERENCE MANUAL 2 1 1.2 APPLICATIONS The DS6400 barcode reader is specifically de signed for industrial applications and for all cases requiring high reading perform ance such as: code rec.
INTRODUCTION 3 1 Feature Benefit Master working as a Multiplexer on high speed Lonworks bus Great competitiveness of the offer, since the cost of an external multiplexer is saved; High data transfer on an industrial, reliable bus running at 1,2 Mbit/sec.
DS6400 REFERENCE MANUAL 4 1 1.4 OSCILLATING MIRROR MODELS Oscillating mirror models are used when coverage of a large reading area is required, mainly in picket fence applicatio ns. The DS6400 scanner mounts a dedicated optic head with integrated oscillating mirror driven by a linear motor.
INTRODUCTION 5 1 The mirror can be deflected up to 40°. Oscillation with respect to the output window median axis is asymmetrical ( see figure below).
DS6400 REFERENCE MANUAL 6 1 The following example represents the selection of an ang le of +10° for the bottom line and an angle of +20° for the top line (see figure below). +17.5° +37.5° +27.5° Figure 5 - Oscillating Mode Refer to chapter 2 for more information on scanner mounting and positioning.
INTRODUCTION 7 1 1.6.1 Internal Net This submenu can be used as an alternative to configuratio n through Genius™, to assign the DS6400 scanner within a local Lonworks master/slave network. It allows defining the scanner function (slave/master) within the Lonworks network and, if configured as Slave, its address.
DS6400 REFERENCE MANUAL 8 1 1.6.3 PackTrack (Auto) This submenu can be used to execute the Automatic PackTrack Calibration procedure for the Reading Station when the Master scanner is in PackTrack or Continuous Operating Modes.
INTRODUCTION 9 1 1.7 AUTO PACKTRACK™ CALIBR ATION FOR READI NG STATION USING SCANNER MENU 1.7.1 Auto PackTrack Conditions and Limits The Conditions and Limits for Auto PackTrack Calibra tion are sum.
DS6400 REFERENCE MANUAL 10 1 1.7.2 Auto PackTrack Parameter Descriptions Menu Branch Default Note PackTrack Automatic Packtrack Calibration procedure for the Reading Station Version 2 Select the version number of the PCT-8000 pack Cal Type XYZ XYZ calibration is forced.
INTRODUCTION 11 1 Z Offset (if necessary): for packs that are elevat ed above th e conveyor surface (for example on tilt trays), this parameter sets an offset for the height o f a pack so that Z = 0 corresponds to the bottom of the pack.
DS6400 REFERENCE MANUAL 12 1 Figure 6 - PCT-8000 First Run After elaborating the passage of t he parcel, the Master scanner again shows the status of each node (of each scanner of the cluster) and then the Continue or Stop screen. 6. Repeat steps 3 - 5 chan ging the PCT-8000 X position (i.
INTRODUCTION 13 1 7. At the last step in the sequence the displa y prompts to place a barcode label centered onto the physical X position (X Offset) on the conveyor. Press the ENT (enter) key to Continue. You have 2 minutes to read the code before the procedure ends automatically.
DS6400 REFERENCE MANUAL 14 1 1.8 ACCESSORIES The following accessories are available on request for DS6400: Name Description Part Number Power Supplies PG6002 Single unit power supply (US) 93ACC1718 P.
INTRODUCTION 15 1 Name Description Part Number Mirrors GFC-60 90° mirror 93A201100 GFC-600 90° mirror close distance 93A201102 * Connection Boxes CBX100 Compact Connection Box 93A301067 CBX500 Modul.
DS6400 REFERENCE MANUAL 16 2 2 INSTALLATION To install the system follow the given procedure: 1. Select the mounting location for DS6400; 2. Mount the DS6400 scanner; 3. Position the scanner with respect to the barcode; 4. Proceed with system electrical connection; 5.
INSTALLATION 17 2 2.2 MECHANICAL MOUNTING 2.2.1 Mounting the Scanner The DS6400 reader can be positioned and installed in the best way possible as a result of the patented Step-a-Head™ feature.
DS6400 REFERENCE MANUAL 18 2 The following diagrams give the overall dimensions of the reader standard model, oscillating mirror model and mounting brackets. They may be used for their installation. 4.33 4.45 110 113 99 3.90 76 30 74 2.99 1.18 2.85 85 16.
INSTALLATION 19 2 3.35 0.65 2.36 1.18 3.90 2.72 4.11 2.50 4.34 4.01 2.20 4.48 4.45 7.08 mm inch 30 60 85 16.5 104.5 63.5 69 99 113 114 56 110.3 102 180 Figure 13 - DS6400 Oscillating Mirro r Model Overall Dimensions 1.65 0.4 0.86 0.98 0.71 3.22 1.96 0.
DS6400 REFERENCE MANUAL 20 2 2.2.2 Mounting the Scan ner with Accessories The following accessories allow inst alling the DS6400 reader in the most suitable p osition for your network layout: - ST-237 mou nting bracket; - ST-210 mou nting bracket; - FBK-6000 fast bracket.
INSTALLATION 21 2 The FBK-6000 is a fast bracket kit allowing a quick and easy mounting of the scanner on th e ST-237 bracket. First, it is necessary to fix the FBK-6000 to the DS6400 scanner by means.
DS6400 REFERENCE MANUAL 22 2 2.3 POSITIONING THE SCANNER The DS6400 reader is able to decode moving barcode labels at a variety of angles, however significant angular distortion may degrade reading performance. When mounting DS6400 take into consideration these three ideal label posit ion angles: Pitch 0° , Skew 10° to 30° and Tilt 0° .
INSTALLATION 23 2 The Tilt angle is represented by the value T in Figure 21. Figure 21 - "Tilt" A ngle 2.3.1 16° Skew Positioning The DS6400 scanner is mounted on the ST-237 106° mounting .
DS6400 REFERENCE MANUAL 24 2 2.3.2 45° Skew Positioning The DS6400 scanner is mounted on the ST-210 90° mounting bracket (see Figure 14). By adjusting th e mounting bracket guides, reach 45° for th.
CBX ELECTRICAL CONNECTIONS 25 3 3 CBX ELECTRICAL CONNECTIONS Each scanner model has the following connectors: Scanner Model Connectors Master/Slave 25-pin male serial interface and I/O connector 9-pin.
DS6400 REFERENCE MANUAL 26 3 The table below gives the pinout of the CBX100/500 terminal block connectors. Use this pinout when the DS6400 reader is connected by means of the CBX100/500: CBX100/500 Te.
CBX ELECTRICAL CONNECTIONS 27 3 NOTE To avoid electromagnetic interference when the scanner is connected to a CBX connection box, verify the jumper positions in the CBX as indicated in its Installation Manual.
DS6400 REFERENCE MANUAL 28 3 3.2.1 RS232 Interface The main serial interface is used in this case for point- to-point connections; it handles communication with the host computer and allows both transmission of code data and the programming of the scanner.
CBX ELECTRICAL CONNECTIONS 29 3 3.2.2 RS485 Full-Duplex Interface The RS485 full-duplex (5 wires + shield) interface is used for non-polled communication protocols in point-to-point connections over lon ger distances (max 1200 m / 3940 ft) than those acceptable for RS232 communications or in electrically noisy environments.
DS6400 REFERENCE MANUAL 30 3 3.2.3 RS485 Half-Duplex Interface NOTE This interface is provided for backward compatibility. We recommend using the more efficient Lonworks network for Master/Slave or Multiplexer layouts. The RS485 half-duplex (3 wires + shield) interface is used for polled communication protocols.
CBX ELECTRICAL CONNECTIONS 31 3 #1 #0 (up to 31) Scanner Scanner Scanner Slave Slave Slave Main Interf ace RS232/RS485 HOST Multidrop GND Shield Multid rop - Multid rop + 1200 m Max Length Multidrop C.
DS6400 REFERENCE MANUAL 32 3 3.3 AUXILIARY RS232 INTERFACE The auxiliary serial interface is used exclusiv ely for RS232 point-to-point connections. It is principally used for scanner configuration from a laptop PC but is also available for LOCAL ECHO to a monitoring PC or for Pass through layouts.
CBX ELECTRICAL CONNECTIONS 33 3 3.4 INPUTS There are four optocoupled polarity insensitive inputs available on the scanner: Input 1 (External Trigger/PS), Input 2 (Encoder), Input 3 and 4 generic inputs.
DS6400 REFERENCE MANUAL 34 3 The driving logic of the input signals may be powered, for convenience, with the voltage supply at the CBX terminal block spring clamp s (V+) and (V-). In this case, however, the device is no longer electrically isolate d.
CBX ELECTRICAL CONNECTIONS 35 3 INPUT 2 (ENCODER) CONNECTIONS USING DS6400 POWER (r e d ) (wh i te ) O E K -1 En co d e r (P N P ) (b l a ck ) Figure 37 - OEK-1 Encoder PNP Usin g DS6400 Power P ower .
DS6400 REFERENCE MANUAL 36 3 NOTE Terminal pins I34B are common to both inputs 3 and 4 and therefore these inputs cannot be driven by opposite polarity de vices.
CBX ELECTRICAL CONNECTIONS 37 3 3.4.1 Code Verifier If the DS6400 is used as a Code Verifier, the verifier code can be configured in software through the Genius™ configuration program. However it is also possible to u se one of the inputs to trigger when the scanner should store a code read as the verifier code.
DS6400 REFERENCE MANUAL 38 3 The function of each output can be defined by t he user (No Read, Right, Wrong, etc.). Refer to the Genius™ Help On Line. The output signals are fully programmable being determined by the configured Activation/Deactivation events, Deactivation Timeout or a combination of the two.
CBX ELECTRICAL CONNECTIONS 39 3 OUTPUT 1 and 2 CONNECTIONS USING EXTERNAL POWER Ou t pu t D e vi ce P owe r Refe renc e O utput S ig n a l Out p u t D evi ce Figure 47 - Open Emitter Ou tput Using Ext.
DS6400 REFERENCE MANUAL 40 3 OUTPUT 3 CONNECTIONS USING EXTERNAL POWER (CBX500 Only) Output Signal External Device Power or Ground Re ferenc e Figure 51 - Ouput 3 Usin g External Power The command signals are filtered and generate a delay of about 50 µs for Output 1 and 2 and 1 ms for Output 3.
CUSTOM CABLE ELECTRICAL CONNE CTIONS 41 4 4 CUSTOM CABLE ELECTRICAL CONNECTIONS Each scanner model has the following connectors: Scanner Model Connectors Master/Slave 25-pin male serial interface and .
DS6400 REFERENCE MANUAL 42 4 The details of the connector pins are indicated in the following table: 14 1 25 13 10 19 1 18 9 26 Figure 52 - 25-pin Conne ctor Figure 53 - 26 -pin Connector DS6400 25/26.
CUSTOM CABLE ELECTRICAL CONNE CTIONS 43 4 4.1 POWER SUPPLY The supply voltage for correct operation of the scanner must be betwe en 15 and 30 VDC. The max. power consumption is 24 W including startup current. Datalogic strongly recommends a minimum 24 Vdc supply voltage when using a master/slave configuration.
DS6400 REFERENCE MANUAL 44 4 4.2.1 RS232 Interface The main serial interface is used for communication with the Host computer and allows both transmission of code data and configuring the reader. The overall maximum cable length should not exceed 15 m (50 ft).
CUSTOM CABLE ELECTRICAL CONNE CTIONS 45 4 4.2.2 RS485 Full-Duplex Interface The RS485 full-duplex (5 wires + shield) interface is used for non-polled communication protocols in point-to-point connections over lo nger distances than those acceptable for RS232 communications or in electrically noi sy environments.
DS6400 REFERENCE MANUAL 46 4 4.2.3 RS485 Half-Duplex Interface NOTE This interface is provided for backward compatibility. We recommend using the more efficient Lonworks network for Master/Slave or Multiplexer layouts. The RS485 half-duplex (3 wires + shield) interface can be used for p olled communication protocols.
CUSTOM CABLE ELECTRICAL CONNE CTIONS 47 4 Figure 60 – DS6400 Multid rop Connection to a Multiplexer.
DS6400 REFERENCE MANUAL 48 4 4.3 AUXILIARY INTERFACE The auxiliary serial interface is used exclusiv ely for RS232 point-to-point connections. It is principally used for scanner configuration from a laptop PC but is also available for LOCAL ECHO to a monitoring PC or for Pass through layouts.
CUSTOM CABLE ELECTRICAL CONNE CTIONS 49 4 the same value which usually corresponds to 5 ms when us ing a photoelectric sensor, while I2 is set to 500 s when this input is used for the Encoder.
DS6400 REFERENCE MANUAL 50 4 INPUT 1 - 2 CONNECTIONS USING EXTERNAL POWE R E X T E RN AL T R I G G E R / E N C OD E R DS 6 40 0 + 5 V A/B Vext B/ A V ~ ~ + - Gr ou nd Figure 64 – PNP Command Input C.
CUSTOM CABLE ELECTRICAL CONNE CTIONS 51 4 INPUT 3 - 4 CONNECTIONS USING EXTERNAL POWE R E XTE R N A L DEV I CE D S 6 400 I3A Vext G r o un d V + 5 V ~ ~ + - Gro u n d V I4A + 5V ~ ~ + - I34B Vext Figure 67 - I3/I4 PNP Input Command using External Power 4.
DS6400 REFERENCE MANUAL 52 4 Output 3 has different electrical features. It is a bi-directional solid state relay with built-in current limit protection. Output 3 Maximum Voltage ± 100 V ( Vext only ) Collector Current (pulse) 300 mA Max. at 25°C (Ambient temperature) 240 mA Max.
CUSTOM CABLE ELECTRICAL CONNE CTIONS 53 4 DS 6 40 0 U SER I N T ERF A C E V ex t 100 V dc max A/ B B/ A Figure 69 – Outp ut 3 Interface The command signals are filtered and generate a delay of about 50 µs for Output 1 and 2 and 1 ms for Output 3. 4.
DS6400 REFERENCE MANUAL 54 5 5 LONWORKS CO NNECTIONS CAUTION Do not connect an RS232 port to the 9-pin Lonworks Connector. This may damage your Laptop PC . The local network used by DS6400 exploi ts a Lonworks standard communication system requiring only two wires (polarity insensitive) to enable a connection.
LONWORKS CONNECTIO NS 55 5 5.1 NETWORK TERMINATION When building a Lonworks system the network must be properly terminated by positioning the BT-6000 Lonworks terminator in the DS6400 master reader and in the last DS6400 slave reader.
DS6400 REFERENCE MANUAL 56 5 The following diagram represents the connection between a DS6400 working as master and a DS6400 working as a slave reader.
LONWORKS CONNECTIO NS 57 5 The diagram below represents the termination of a DS6400 (Master/Slave model) working as master by means of the BT-6000. Ma ste r BT - 600 0 F em al e Si d e = ma le co n n .
DS6400 REFERENCE MANUAL 58 6 6 FIELDBUS CONNECTIO NS 6.1 ETHERNET INTERFACE This connector is only available f or DS6400 Ethernet models and allows the Ethernet connection between the host and the reader. Figure 77 –DS64 00 M12 4-pin D-Coded Fem ale Ethernet Connector This interface and the connector pinout (see the following table) are IEEE 802.
FIELDBUS CONNECTIONS 59 6 6.2 ETHERNET INTERFACE (OLDER MODELS) The RJ45 connector is only available for older DS6400 Ethernet models and allows the Ethernet connection between the host and the reader. 1 8 Figure 79 – DS6400 RJ4 5 Female Modular Connector This interface and the connector pinout (see the following table) are IEEE 802.
DS6400 REFERENCE MANUAL 60 6 The Ethernet interface can be used for TCP/IP communication with a remote or local host computer by connecting the scanner to a LAN.
FIELDBUS CONNECTIONS 61 6 6.3 DEVICENET INTERFACE NOTE When using DeviceNet, the Main serial interface is disabled and must not be physically connected.
DS6400 REFERENCE MANUAL 62 6 6.4 PROFIBUS INTERFACE The 9-pin Profibus female connector (white) is only available in the DS6400 Profibus model and allows connection between the host and the reader: 5 1 9 6 Figure 83 - Profibus 9 -pin Fema le Connector DS6400 9-pin Profibus connector pinout Pin Name Function 1 Shield* Shield, Protective Ground resp.
TYPICAL LAYOUTS 63 7 7 TYPICAL LAYOUTS DS6400 scanners are mainly designed to work together on a high performance Lonworks sub-network to create multi-sided and omnidirectional reading stations that can interface with Serial or Fieldbus Host networks.
DS6400 REFERENCE MANUAL 64 7 NOTE For some DS6400 Lonworks Network layouts, power is pro pagated through the 9-pin scanner connectors. A specific jumper setting is required in CBXs to pass scanner power to the presence sensor, encoder, etc.
TYPICAL LAYOUTS 65 7 The following image shows a system consisting of five reade rs (mixed 8K and 6K) where the external signals (trigger, encoder, serial to host , etc.) are connected to the master through the CBX100. Note: In a mixed 8K and 6K family scanner network, only the 8K family scanner can be Master.
DS6400 REFERENCE MANUAL 66 7 7.1.2 Multidata Network In this layout, one master and up to 7 DS6400 slave readers have their own P.S. and therefore multiple reading phases. Each P.S. is connected through a CBX100, which in turn is connected to its relative scanner through a CAB-Sxx cable.
TYPICAL LAYOUTS 67 7 7.1.3 Fieldbus Networks The Fieldbus models (Ethernet, DeviceNet, or Profibus) offer connectivity without any converter or adapter needed.
DS6400 REFERENCE MANUAL 68 7 NOTE To interface DS6400 scanners to other Host types (Fieldbus and no n- Fieldbus), use the CBX800 Gateway with Host Interface Modules. The Master scanner in this case is a standard Master/Slave Serial model which requires the BT-6000 terminator.
SOFTWARE CONFIGURA TION 69 8 8 SOFTWARE CO NFIGURATION 8.1 GENIUS™ INSTALLATION Genius ™ is a new Datalogic scanner configurat ion tool providing several important advantages: Wizard approach .
DS6400 REFERENCE MANUAL 70 8 After defining the parameter values the following window appears allowing to complete the reader configuration as follows: - Saving the configuration to disk; - Switching to Advanced mode; - Sending the configuration to the scanner.
SOFTWARE CONFIGURA TION 71 8 On Line Operating Mode Figure 92 - On Line Mode Se lection This operating mode causes the reader to be connected to an external Presence Sensor using I1A and I1B (External Trigger/PS) inputs. During the active phase of the presence sensor, the DS6400 reader tries to acquire and correctly decode the code.
DS6400 REFERENCE MANUAL 72 8 8.2.2 Genius™ Network Setup Through Master Network Setup allows configuring your Local Lonworks Network through the Master using Genius™.
SOFTWARE CONFIGURA TION 73 8 The following dialog box appears asking whether to send the configuration to the Local Device or not: 2. Click the "Yes" button, then click on the icon available on the Toolbar to make the “Devices” area appear next to the Parameter Explorer window.
DS6400 REFERENCE MANUAL 74 8 3. Then, proceed with the network setup by using one of the icons available on the Tool Bar according to the procedure to follow: = Net-Autoset procedure = Network Wizard .
SOFTWARE CONFIGURA TION 75 8 Network Wizard Before performing this procedure, a Lonworks address must be assigned to each slave scanner. The most practical method is through the Net-Autoset procedure. See par. 8.2.3 for alternative address assignment methods.
DS6400 REFERENCE MANUAL 76 8 2. If desired, select a slav e scanner within the "Current Devices" area and click on the icon (or select the "Show Device" option from the right-click.
SOFTWARE CONFIGURA TION 77 8 8.2.3 Alternative Sla ve Address Assignment As alternatives to Network Setup through the Master, each Slave scanner can be assigned an address through the following method.
DS6400 REFERENCE MANUAL 78 8 8.3.1 Genius™ Shortcuts fo r Net work Configuration Once the Network Setup is structured in Genius and the Master is configured, there are a few shortcuts that Genius offers to quickly configure the slaves.
SOFTWARE CONFIGURA TION 79 8 It is possible to Paste, Send or Load configurations simultaneously 1 to a selected number of devices by clicking the relative device check box and executing the desir ed command. These same functions 2 can be selected from the Edit menu as well.
DS6400 REFERENCE MANUAL 80 8 8.4 PARAMETE R DEFAULT VA LUES The following table contains the list of the factor y default settings for the DS6400. Genius™ also allows checking the parameter default .
SOFTWARE CONFIGURA TION 81 8 Parameter Default Setting Reading Parameters Beam Shutter Disabled Overflow Start Ratio 5 Overflow Stop Ratio 5 Reading Mode Reconstruction Reading Condition Standard Reco.
DS6400 REFERENCE MANUAL 82 8 Parameter Default Setting Parameters Stop Bits 1 Auxiliary Serial Port Search for CBX BM100 at Device Startup Enabled (checked) Data Tx Enabled (checked) Heartbeat Disable.
SOFTWARE CONFIGURA TION 83 8 Parameter Default Setting Diagnostics PackTrack Debug Message Tx Disabled (unchecked) Enable Checked Conveyor Info Not Available Refresh Time 2 sec Statistics Enabled (che.
DS6400 REFERENCE MANUAL 84 9 9 READING FEATURES 9.1 DS6400 FLASH™ DYNAMIC FOCUS The DS6400 has an innovative linear motor designed to control the focus position of the scanner via software. This dynamic system, called FLASH™ , is able to move the focus position rail to rail, from the minimum position to the maximum position.
READING FEATURES 85 9 9.1.3 Triggered Mode In Triggered mode, the focus position can be set depending on the received external input (photocell, barrier, serial message…). This mode represents the most traditional Flash™ function, since it requires photocells, barriers or a dedicate d interface to the Host (PC or PLC).
DS6400 REFERENCE MANUAL 86 9 9.2 ADVANCED CODE RECONSTRUCTION (ACR™ 4) The traditional way of barcode reading could be called “Linear Reading”. In this case, the laser beam crosses the barcode s.
READING FEATURES 87 9 The decoder will be able to read th e label with a tilt angle between + max and - max as shown in the following figure: Conveyor Laser Beam No Read No Read - + 0 ° O K O K O K O K O K No Read Figure 104 – Readi ng Zones w ith Max 9.
DS6400 REFERENCE MANUAL 88 9 For correct functioning, t he PackTrack™ operating mode requires a calibration just after the installation of the scanners. This operation is absolutely necessary to accurately locate barcodes on a fixed reference system.
READING FEATURES 89 9 9.3.1 Auto PackTrack™ Calibration for Reading Station Usi ng DLAPC In a Master /Slave Reading Station working in PackTrack™ or Continuous operating mode, the entire Reading Station can be automatically calibrated using the DLAPC tool in Genius™.
DS6400 REFERENCE MANUAL 90 9 Auto PackTrack Parameter Descriptions By means of the software tool DLAPC, it is possible to perform the Auto PackTrack setup procedure for PackTrack™ and Continuous Operating Mode applications.
READING FEATURES 91 9 Calibration Type : XYZ calibration with Absolute X position is forced. The coordinates for the three axes are calibrated. The X coordinate f or all slaves is relative to a precise point (reference point). This requires that the X Offset be set which will be used to harmonize the X=0 coordinate of all of the individual slaves.
DS6400 REFERENCE MANUAL 92 9 Auto PackTrack Setup 1. Click on the Start button and follow the instructions given in the Auto PackTrack procedure window. The first message is sent to the slaves and thei r status is shown in the synoptic buttons at the top of the window.
READING FEATURES 93 9 NOTE If there are any nodes that show as U or L , then you should Stop the procedure and correct the problem. If the nodes respond with I , N , or C then you can Continue with the procedure. To run each instruction press the Next button.
DS6400 REFERENCE MANUAL 94 9 3. The Absolute X coordinate requires placing a barcode label centered onto the physical X position (X Offset) on the conveyor (previously set in the dialog box), you have 2 minutes to read the code before the procedure ends automatically.
READING FEATURES 95 9 Auto PackTrack Report The Auto PackTrack Report file can be downloaded from the Master scanner RAM by using the Tools>File transfer… menu in Genius™.
DS6400 REFERENCE MANUAL 96 9 The last section summarizes the calibration status of each scanner. ----------- ------------ ----------- ---- SCANNERS STATE SUMMARY ----------- ------------ ----------- -.
READING FEATURES 97 9 1. Select the “SPY” option from the Tools menu or click on the related icon on the Genius™ toolbar to open the following dialog box: NOTE When selecting a slave scanner through the Master, click on the slave in the Devices window, then click the SPY icon.
DS6400 REFERENCE MANUAL 98 9 3. By selecting the “PackTrack Calibration” option a further dialog box appears allowing to start calibration: Figure 111 – Performin g the PackTrack™ Calib ration 4. Place the code at one of the desired positions on the scan line (i.
READING FEATURES 99 9 7. Repeat the same procedure for Position 2 and Position 3. 8. After calibrating the 3 positions, press the “Validate Calibration” button to validate the calibration settings. Before closing the dialog box, press the Run Test button to test the calibration results and efficiency.
DS6400 REFERENCE MANUAL 100 9 9.4 PERFORMANCE The scan rate is 800 scans/sec. Refer to the diagrams in par. 9.5 for further details on the re ading features. These diagrams are taken o n various resolution sample codes at a 25 C ambient temperature depending on the conditions listed under each dia gram.
READING FEATURES 101 9 Minimum Code Height for ACR Reading (mm) 45° 30° Conveyor Speed (m/s) 0.5 1 1.5 2 2.5 3 0.5 1 1.5 2 2.5 3 0.25 8 9 11 13 15 17 5 7 8 10 11 13 0.30 8 10 12 14 16 18 6 7 9 10 12 13 Code 128 – GS1-128 0.33 9 11 13 14 16 18 6 8 9 11 12 14 Code Resolution 0.
DS6400 REFERENCE MANUAL 102 9 9.5 READING DIAGRAMS The reading diagram given below illustrates the convention used to calculate the minimum and maximum reading distance for barcodes.
READING FEATURES 103 9 9.5.1 DS6400 Standard Model DS6400-100-0XX Resolution: 0.20 mm/8 mils The diagram shows a global reading area, whic h includes all possible focus positions, and the reading area obtained for the DS6400-100-0XX operating with f ocus position = 65 cm and barcode density of 0.
DS6400 REFERENCE MANUAL 104 9 The curves show the minimum and maximum radial distance. 38 36 85 40 (in) 100 95 34 (cm) 90 80 75 70 65 60 26 24 28 30 32 55 22 0 40 45 50 55 60 65 70 75 (cm) 80 85 90 95 100 0 16 22 (in) 18 20 24 26 30 28 32 34 38 36 40 50 45 40 20 18 16 Min.
READING FEATURES 105 9 DS6400-100-0XX - Resoluti on: 0.25 mm/10 mils The diagram shows a global reading area, whic h includes all possible focus positions, and the reading area obtained for the DS6400-100-0XX operating with f ocus position = 90 cm and barcode density of 0.
DS6400 REFERENCE MANUAL 106 9 The curves show the minimum and maximum radial distance. 42 40 95 44 (in) 110 105 38 (cm) 100 90 85 80 75 70 30 28 32 34 36 65 26 0 45 50 55 60 65 70 75 80 (cm) 85 90 95 100 105 18 24 (in) 20 22 26 28 32 30 34 36 40 38 42 60 55 50 24 22 20 Max.
READING FEATURES 107 9 DS6400-100-0XX - Resoluti on: 0.30 mm/12 mils The diagram shows a global reading area, whic h includes all possible focus positions, and the reading area obtained for the DS6400-100-0XX operating with focus position = 110 cm and barcode density of 0.
DS6400 REFERENCE MANUAL 108 9 The curves show the minimum and maximum radial distance. 60 56 130 64 (in) 160 150 52 (cm) 140 120 110 100 90 80 36 32 40 44 48 70 28 0 55 60 65 70 75 80 85 90 (cm) 95 100 105 11 0 115 22 28 (in) 24 26 30 32 36 34 38 40 44 42 46 60 50 40 24 20 16 Max.
READING FEATURES 109 9 DS6400-100-0XX - Resoluti on: 0.38 mm/15 mils The diagram shows a global reading area, whic h includes all possible focus positions, and the reading area obtained for the DS6400-100-0XX operating with focus position = 140 cm and barcode density of 0.
DS6400 REFERENCE MANUAL 110 9 The curves show the minimum and maximum radial distance. 60 56 130 64 (in) 160 150 52 (cm) 140 120 110 100 90 80 36 32 40 44 48 70 28 0 50 60 70 80 90 100 1 10 120 (cm) 130 1 40 150 160 170 20 32 (in) 24 28 36 40 48 44 52 56 64 60 68 60 50 40 24 20 16 Max.
READING FEATURES 111 9 DS6400-100-0XX - Resoluti on: 0.50 mm/20 mils The diagram shows a global reading area, whic h includes all possible focus positions, and the reading area obtained for the DS6400-100-0XX operating with focus position = 120 cm and barcode density of 0.
DS6400 REFERENCE MANUAL 112 9 The curves show the minimum and maximum radial distance. 64 60 140 68 (in) 170 160 56 (cm) 150 130 120 110 100 90 40 36 44 48 52 80 32 0 50 60 70 80 90 100 1 10 120 (cm) 130 140 150 160 170 20 32 (in) 24 28 36 40 48 44 52 56 64 60 68 70 60 50 28 24 20 Max.
READING FEATURES 113 9 9.5.2 DS6400 Oscillating Mirror Model DS6400-105-0XX - Resolution: 0.20 mm/8 mils The diagram shows a global reading area, whic h includes all possible focus positions, and the reading area obtained for the DS6400-105-0XX operating with f ocus position = 60 cm and barcode density of 0.
DS6400 REFERENCE MANUAL 114 9 The curves show the minimum and maximum radial distance. 36 85 (in) 34 (cm ) 90 80 75 70 65 60 26 24 28 30 32 55 22 0 40 45 50 55 60 65 70 75 (cm) 80 85 90 0 16 22 (in) 18 20 24 26 30 28 32 34 36 50 45 40 20 18 16 Min. Readi ng Distance Max.
READING FEATURES 115 9 DS6400-105-0XX - Resoluti on: 0.25 mm/10 mils The diagram shows a global reading area, whic h includes all possible focus positions, and the reading area obtained for the DS6400-105-0XX operating with f ocus position = 95 cm and barcode density of 0.
DS6400 REFERENCE MANUAL 116 9 The curves show the minimum and maximum radial distance. 40 38 90 42 (in) 105 100 36 (cm) 95 85 80 75 70 65 28 26 30 32 34 60 24 0 45 50 55 60 65 70 75 80 (cm) 85 90 95 100 1 05 18 24 (in) 20 22 2 6 28 32 30 34 36 40 38 42 55 50 45 22 20 18 Max.
READING FEATURES 117 9 DS6400-105-0XX - Resoluti on: 0.30 mm/12 mils The diagram shows a global reading area, whic h includes all possible focus positions, and the reading area obtained for the DS6400-105-0XX operating with focus position = 110 cm and barcode density of 0.
DS6400 REFERENCE MANUAL 118 9 The curves show the minimum and maximum radial distance. 6 0 5 6 13 0 6 4 (in ) 16 0 15 0 5 2 (c m) 14 0 12 0 11 0 10 0 90 80 3 6 32 4 0 4 4 4 8 70 28 0 50 55 60 65 7 0 7 5 80 85 (c m) 90 95 10 0 10 5 11 0 20 2 6 ( in ) 22 2 4 2 8 30 34 32 36 3 8 42 40 4 4 60 50 40 24 20 16 Ma x.
READING FEATURES 119 9 DS6400-105-0XX - Resoluti on: 0.38 mm/15 mils The diagram shows a global reading area, whic h includes all possible focus positions, and the reading area obtained for the DS6400-105-0XX operating with focus position = 115 cm and barcode density of 0.
DS6400 REFERENCE MANUAL 120 9 The curves show the minimum and maximum radial distance. 60 56 130 64 (in) 160 150 52 (cm) 140 120 110 100 90 80 36 32 40 44 48 70 28 0 50 60 70 80 90 100 110 120 (cm) 130 140 150 160 170 20 32 (in) 24 28 36 40 48 44 52 56 64 60 68 60 50 40 24 20 16 Max.
READING FEATURES 121 9 DS6400-105-0XX - Resoluti on: 0.50 mm/20 mils The diagram shows a global reading area, whic h includes all possible focus positions, and the reading area obtained for the DS6400-105-0XX operating with focus position = 115 cm and barcode density of 0.
DS6400 REFERENCE MANUAL 122 9 The curves show the minimum and maximum radial distance. 60 56 130 64 (in) 160 150 52 (cm) 140 120 110 100 90 80 36 32 40 44 48 70 28 0 50 60 70 80 90 100 110 120 (cm) 130 140 150 160 170 20 32 (in) 24 28 36 40 48 44 52 56 64 60 68 60 50 40 24 20 16 Max.
MAINTENANCE 123 10 10 MAINTENANCE 10.1 CLEANING Clean the laser beam output window periodically for correct operation of the scanner (see Figure A). Dust, dirt, et c. on the window may alter the reading performance. Repeat the operation frequently in particularly dirty environments.
DS6400 REFERENCE MANUAL 124 10 The ASR procedure is principally used for PackTrack™ configurations, but it restor es only a part of the system parameters: commo n slave parameters (Code Selection and Reconstruction) plus each single slave PackTrack™ calibration.
TROUBLESHOOTING 125 11 11 TROUBLESHOOTING NOTE Before contacting your local Datalogic off ice or Datalogic Partner or ARC, it is suggested to save the device configuration to a *.ddc file by m eans of the Genius™ software configuration program and check the device exact model and serial number.
DS6400 REFERENCE MANUAL 126 11 TROUBLESHOOTING GUIDE Problem Suggestion On Line Mode and Serial On Line Mode: the reader does not respond correctly to the expected external signal end. In the Genius™ software configuration program select the OPERATING MODES folder and check the “Reading Phase Timeout” parameterization.
TROUBLESHOOTING 127 11 TROUBLESHOOTING GUIDE Problem Suggestion How do I obtain my units’ serial numbers? The device serial number is printed on a label that is affixed above the connector panel of the reader. The serial number is also displayed when connecting the device through the Genius™ program.
DS6400 REFERENCE MANUAL 128 12 12 TECHNICAL FEATURES ELECTRICAL FEATURES Supply Voltage 15 to 30 Vdc Power Consumption 15 W typical 1.5 to 0.7 A max. (including startup current) Main Baud Rate RS232 RS485 full-duplex RS485 half-duplex 1200 to 115200 Auxilia ry RS232 1200 to 115200 Other Common Communication Interfaces Lonworks 1.
TECHNICAL FEATURES 129 12 SOFTWARE FEATURES Readable Codes I nt erl eav ed 2/ 5 Code 39 Standard Codabar Code 128 GS1-128 (ex EAN 128) Code 93 (standard a nd full ASCII) EAN /UP C (including Add-on 2 .
DS6400 REFERENCE MANUAL 130 A A ALTERNATIVE LAYOUTS POINT-TO-POINT Using a Point-to-Point layout, the data is transmitted on the Main interface as well as on the Auxiliary interface. The Main interface can be selected for RS232 or RS485 full-duplex communications.
ALTERNATIVE LAYOUTS 131 A Fieldbus Models In this case no External Trigger is used and the CBX 100/CBX500 only passes power to the reader. The DS6400 Fieldbus models (Ethernet, DeviceNet or Profibus) are connected to a remote Host.
DS6400 REFERENCE MANUAL 132 A ID-NET™ GATEWAY The CBX800 Gateway can be used to integrate a DS6400 reader into a high speed ID- NET™ network consisting of different scanners not provided with a Lonworks interfac e. In this case the DS6400 uses its main RS232/RS485 interface to communicate with the CBX800.
ALTERNATIVE LAYOUTS 133 A PASS THROUGH When Pass Through is activated on the Auxiliary interface, the DS6400 reader can be integrated in a network consisting of different scanners not provided with a Lonworks interface. This connection mode allows two or more devices to be connected to a single external serial interface.
DS6400 REFERENCE MANUAL 134 A 1 2 Main Seri al Interface A uxiliar y Ser ial In ter fa ce * P. S. (Presence Sensor) connected t o Input 1 (External T rigger/PS) input.
ALTERNATIVE LAYOUTS 135 A Figure 140 – RS232 Maste r/Slave for DS6400 Ma ster/Sla ve Models Figure 141 – RS232 Master/Slave for DS6400 Fieldbus Models 3 Main Serial Interface (RS232 only) .
DS6400 REFERENCE MANUAL 136 A MULTIPLEXER The Multiplexer connection is used to integrate a DS6400 slave reader in a Multidrop network consisting of different scanners not provided with a Lonworks int erface. Each scanner is connected to a Multiplexer (MX4000) with the RS485 half-duplex main interface.
137 GLOSSARY ACR™ 4 Each version of the base has the powerful cod e reconstruction technology (ACR™ 4). The new fourth generation ACR™ considerably increases the code reconstruction reading capability in the case of damaged or very tilted barcodes.
138 Multidrop Line A single communications circuit that interconnects many stations, each of which contains terminal devices. See RS485. PackTrack™ PackTrack™ is a Datalogic patented parcel tr acking system which improves the readin g features in omnidirectional stations.
139 UPC Acronym for Universal Product Code. The standard barcode type for retail food packaging in the United States. Visible Laser Diode A light source used in scanners to illuminate the barcode sy mbol. Generates visible red light at wavelengths between 630 and 680 nm.
140 INDEX A Accessories, 14 ACR™ 4, 86 Alternative Layouts, 130 Auto PackTrack Conditions and Limits, 9, 89 Parameter Descriptions, 10, 90 Report, 95 Setup Procedure, 11, 92 Setup using Keypad, 8 Au.
141 Point-to-Point, 130 Positioning, 22 16° Skew Positioning, 23 45° Skew Positioning, 24 Power Supply, viii, 27, 43 Profibus Connector Panel, xiii Profibus Interface, 62 R Reading Diagrams, 102 Osc.
DECLA RA T ION OF CO NFORMIT Y EC-009 Rev.: 5 Pag.: 1 di 1 Datalogic Aut omation S.r.l. Via Lavi no 265 40050 Monte San Pi etro Bologna - Italy ww w.automation.
www .automation.dat alogic.com.
Ein wichtiger Punkt beim Kauf des Geräts Datalogic DS6400-105-012 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Datalogic DS6400-105-012 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Datalogic DS6400-105-012 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Datalogic DS6400-105-012 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Datalogic DS6400-105-012 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Datalogic DS6400-105-012 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Datalogic DS6400-105-012 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Datalogic DS6400-105-012. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Datalogic DS6400-105-012 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.