40 Ser vice Manual W indow T ype Room Air Conditioner Model: DWC-121R / (DWC-124R) DW A-122R / (DW A-124R) DWB-122R / (DWB-124R) DW A-121R / DWB-121R DWB-123R / DW A-150R DW A-151R / (DW A-152R) D AEW OO ELECTR ONICS CO.
CONTENTS 1. Specifications ................................................................................................2 2. Operation .....................................................................................................3 3. Wiring Diagram .
2 1. SPECIFIC A TIONS ITEM MODEL Function Power source AC 115V, 60Hz Cooling Capacity Btu/h 12,100 12,000 12,000 11,700 12,000 11,500 14,018 14,000 Kcal/h 3,050 3,024 3,024 2,950 3,024 2,898 3,533 3,528 Btu/wh 10.1 10.2 10.1 9.9 10.0 10.0 9.4 9.8 Kcal/wh 2.
3 1 P ARTS OF NAME AND FUNCTION 2. OPERA TION ● DW * -121R/DW * -122R/DWB-123R/DW A-150R/DW A-151R (NOTE: * ➔ A or B or C) NO PART NAME 1 AIR FILTER 2 GRILLE FRONT 3 CABINET 4 BLADE VERTICAL 5 PAN.
4 NO PART NAME 1 AIR FILTER 2 GRILLE 3 CABINET 4 BLADE VERTICAL 5 PANEL CONTROL 6 REMOTE CONTROLLER NO PART NAME 7 BLADE HORIZENTAL 8 AIR VENT 9 FRAME GRILLE 10 FRAME GUIDE TOP 11 FRAME WINDOW KIT 12 .
5 2 REMOTE CONTROLLER REMOCON SIGNAL TRANSMITTER TIMER/CANCEL • Everytime you push this button, timer is set as follow. (1Hr → 2Hr → 3Hr → 4Hr → 5Hr → 6Hr → 8 Hr → 10Hr → 12Hr → 16Hr → 20Hr → 24Hr → CANCEL). After the unit is timed, if this button is pushed, timer is canceled.
6 3 REMOTE CONTROLLER DISPLA Y Room Air-conditioner FA N TURBO COOLING ROOM TEMP TEMP DESIRED TEMP TIMER SENSOR MODE POWER FAN SPEED AUTO SWING 88 TEMP./TIMER DISPLAY • It displays the temperature and the timer. MODE DISPLAY • It displays the operating mode.
7 MODE F AN SPEED A UT O SWING PO WER Room Air-conditioner Fan Turbo Cooling Room temp Desired temp Timer TEMP SENSOR TEMP./TIMER DISPLAY • It displays the temperature and the timer. MODE DISPLAY • It displays the operating mode. REMOTE SIGNAL RECEIVER TEMPERATURE SET • It is the button to set the desired room temperature.
8 Replacing Batteries Remov e the CO VER from the back of the remote controller . • Slide the co v er according to the arrow direction Inser t two battaries. • Be sure that the (+) and ( – ) directions are correct • Be sure that both batteries are new Re-attach the cov er .
9 If you set time in OFF-Timer Mode, the unit will stop at the set time. If you set time in ON-Timer Mode, the unit will run at the set time. (1) Range of setting temperature: 16~32 ° C (2) Setting t.
10 (1) When y ou are going to sleep , select sleep b utton in remocon and the unit controls the room to the desired temperature . (The unit will not operate after 4 hour) (2) F or changing the temperature. • Mode I (L1) • The unit will not operate after 4 hour .
11 Auto Swing (1) When you push this b utton, in remocon the left/right flap mov e to the position of k eeping the room temperature comior table. (2) The air discharge direction procedure is below .
12 3. WIRING DIA GRAM (3103529000).
13 4. REFRIGERANT CYCLE Evaporator Capillary tube Blower fan Condenser Propeller fan Accumulator Compressor M MOTOR Capillary tube Charge Quantity DWA-121R ID1.6 Ø x L800 740g DWA-122R (DWA-124R) 790g DWB-121R 730g DWB-122R (DWB-124R) 690g DWC-121R (DWC-124R) 680g DWB-123R 760g DWA-150R 790g DWA-151R (DWA-152R) 780g Model Name Contents ID1.
14 5. CONTR OL BLOCK DIA GRAM Relay 3, 4, 5 Auto Swing Moter Fan Motor Compressor 88 LED Front PCB Fan mode Lamp Turbo mode Lamp Remocon Signal Receiver Cooling mode Lamp Room Temp Lamp Desired Temp L.
15 6. CIRCUIT DIA GRAM.
16 NO PART NAME SPEC PART CODE Q ’ TY REMARK 1 IC MICOM TMP47P443N 13GSHK64-- 1 U1 2 IC DRIVE TD62004AP 13GT62004A 1 U3 3 IC DRIVE TD62783AP 13GT62783A 1 U2 4 IC REGULATOR KIA7812P 1KA7812AP- 1 U4 5 IC REGULATOR KIA7805P 1KA7805AP- 1 U5 6 IC RESET KIA7042P 1KA7042P-- 1 U6 7 FUSE CLIP AFC-520 3107000600 2 FUSE 8 FUSE 250V, 3.
17 NO PART NAME SPEC PART CODE Q ’ TY REMARK 1 LED DISPLAY 88 3103003700 1 DISP 2 C-CERA 103Z 50VDC CXCH1H103M 1 C1 3 RECEIVE MODULE PIC-26043TH2 1PC26043TH 1 REMO 4 LED DLSO-5031D DDLS05031D 3 5 LE.
18 7. TR OUBLE SHOOTING 1) Error Code 1(Er) 1 Check the connector of room air thermistor . (or connecting wire) 2 Check soldering of connecting on control P .C .B. (Error of soldering or shor t) 3 Check the resistance of room air thermistor . “ Press the temperature K eys (Up & Do wn), Error code is display ed.
19 - Check the f ollo wing at cooling mode Check the v oltage between “ PO WER ” and “ RL1 ” of Main P .C .B 3 1 Check the compressor wiring Check the Rela y(RL1) Check the wiring of outdoor unit Check the compressor (Check the winding resistance) Check the compressor capacitor Check the connecting wire between Main P .
PCB DRIVING DESCRIPTION.
21 Power Supply(1) DESCRIPTION DC P o wer Supply in circuit needs +12V and +5V . +12V is used f or Compressor Driving Relay , F an Motor Driving Relay , Buzzer Driving, Swing Motor Dr iving Relay and LED Displa y . AC v oltage of secondar y P o wer T ransf ormer is rectified by 4 Diode, and it is filtering by Main Condensor C2.
22 Oscillation(2) 1 2 8 MHz MICOM V DD -10% V SS +10% Fig 2-1 DESCRIPTION Oscillator y F requency drive Micom, it is made up 8MHz resonator oscillator y F reqency .
23 Room temperature Sensor Input Temperature ( ° C) No. 15 -10 4.06 0 3.60 15 2.76 25 2.20 40 1.48 Voltage (V) Table 3-1 Sensor(3) MICOM 15 R4 300 C13 0.01 R3 12.7K Vcc ROOM:PT-K43C 2 1 DESCRIPTION Number 15 of Micom is T er minal of A/D conv er tor Input.
24 DESCRIPTION Signal from Remote Controller put in only Control Data Signal at Micom T erminal of Number 5, which is gotten field of Carrier (38KHz) from Receive Module. Signal W a v e repeat third as f ollowing Fig 5-1. But in Secondar y W av e Custom Code is Re v ersed F ace .
25 DESCRIPTION MICOM P o wer is supplied 5V at Number 28 using VDD , Number 6 using Analog Reference of A/D Conv er ter . C9, C10 is Ripple filter . Micom Power Supply(5) MICOM 28 14 6 C10 100 µ F/16.
26 Reset(6) + C11 1 µ F/50 R1 5.6K 5V 5V RESET IC MICOM 3 7042 31 2 4.2V H L t t POWER ON Vcc (+5V) DELAY TIME FOR POWER ON RESET DESCRIPTION V oltage less than about 4.2V put in Micom T er minal of Number 6 and then Micom reset. Reset IC detect Pow er ON and V oltage greater than 4.
27 R3 10K R2 10K +5V MICOM 13 27 ˚ F/ ˚ C TEST Function Selecting(7) Table 9-1 Selection S/W SHORT OPEN Function ˚ F / ˚ C ˚ F ˚ C TEST OK NO DESCRIPTION Selecting Function is as follo wing table 9-1.
28 (1) IC3 (MICOM) (2) U2 (TD62783AP) XOUT 1 28 VDD XIN 2 27 HOLD (KE0) TEST RESET 3 26 R92 (SCK) Display Out R70 4 25 R91 (SO) Fan Speed(Hi) Display Out R71 (PULSE) 5 24 R90 (SI) Remocon Signal Displ.
29 (3) U2(TD62004AP) DARLINGTON ARRA YS (4) U7 (7805CT): VOL T AGE REGULA TOR (5VDC) (5) U6 (7812ACT): VOL T AGE REGULA TOR (12VDC) IN1 1 16 OUT 1 IN2 2 15 OUT 2 IN3 3 14 OUT 3 IN4 4 13 OUT 4 IN5 5 12 OUT 5 IN6 6 11 OUT 6 IN7 7 10 OUT 7 GND 8 9 COMMON FREE WHEELING DIODES COM 10.
30 9. DISASSEMBL Y INSTR UCTIONS 1 Before service of 1. Stop the unit, remove the power cord from the receptacles. any part. 2. Move the unit to the safe location for the suitable work. 2 Ass ’ y Fan Motor - Fan Motor - Propeller Fan - Blower Fan 3 Ass ’ y Control Box 1.
31 • HO W T O REMO VE THE FRONT GRILLE FOR ALL MODELS EXCEPT D W ✽ -124R, D W A-152R 1. Pull the Air-filter out of the Front Grille. 2. Loosen screw which fasten Front Grille with driver. 3. Disassemble Front Grille from Chassis. – Front Grille and chassis are fixed with snap-fit.
32 • HO W T O REMO VE THE FRONT GRILLE FOR ONL Y D W ✽ -124R, D W A-152R 1. Open the grille upward by pulling out the bottom of the grille, lift it. 2. Remove screw which fasten Frame Grille with driver. 3. Disassemble Frame Grille from Chassis. – Frame Grille and chassis are fixed with snap-fit.
33 10. EXPLODED DIA GRAM AND P AR TS LIST ■ D W A-121R,D W A-122R(124R),D WB-121R,D WB-122R(124R),D WB-123R, D WC-121R(124R),D W A-150R,D W A-151R(152R) P AR TS LIST NO CODE COMPONENTS Q'TY SPE.
34 NO CODE COMPONENTS Q'TY SPECIFICATION REMARK 3104425820 PIPE DISCHARGE 1 C1220T-O OD7.94 DWA,B-122R,123R,124R(ONLY) 16 3104425810 PIPE DISCHARGE 1 C1220T-O OD7.
35 NO CODE COMPONENTS Q'TY SPECIFICATION REMARK 40 3104302300 PCB MAIN AS 1 – 41 3104302400 PCB FRONT AS 1 – 5EPU04000 TRANSFORMER 1 DWA-220B(115V/60Hz) DWC-121R,124R(ONLY) 42 5EPU04100 TRANS.
■ D W A-121R, D W A-122R, D WB-121R, D WB-122R, D WB-123R, D WC-121R, D W A-150R,.
A-151R D W A-151R EXPLODED DIA GRAM.
■ DW ✻ -124R, D W A-152R EXPLODED DIA GRAM ( NO TE: ✻→ A or B or C).
.
S/M NO .: D WC121R040 D AEW OO ELECTRONICS CO ., L TD . 686, AHYEON-DONG MAPO-GU SEOUL, KOREA C.P.O. BOX 8003 SEOUL, KOREA TELEX: DWELEC K28177-8 CABLE: “ DAEWOOELEC ” FAX: 02) 590-6291 TEL: 02) 360-7114/590-6151~5 http://www.dwe. daewoo.co.kr PRINTED D A TE: APR.
Ein wichtiger Punkt beim Kauf des Geräts Daewoo DWC-121R (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Daewoo DWC-121R noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Daewoo DWC-121R - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Daewoo DWC-121R reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Daewoo DWC-121R erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Daewoo DWC-121R besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Daewoo DWC-121R verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Daewoo DWC-121R. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Daewoo DWC-121R gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.