Crestron Green Light™ DIN-8SW8 DIN Rail High-Voltage Switch Operations & Installation Guide.
This document was prepared and written by th e Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand nam es, product names and trademarks are the property of their respective owners .
Crestron DIN-8SW8 DIN Rail High-Voltage Switch Contents Crestron Green Light™ DIN Rail High-Voltage Switch: DIN-8SW8 1 Introduction .....................................................................................................................
.
Crestron DIN-8SW8 DIN Rail High-Voltage Switch Crestron Green Light™ DIN Rail High-Voltage Switch: DIN-8SW8 Crestron Green Light™ DIN Rail High-Voltage Switch: DIN-8SW8 Introduction Introduction The DIN-8SW8 is an eight cha nnel high-voltage switching module designed to support switching of non-dimmable lighting and fans.
DIN Rail High-Voltage Switch Crestron DIN-8SW8 DIN Rail Installation The DIN-8SW8 is designed to sn ap onto a standard DIN rail for installation in a wall mount enclos ure. Wiring connections are made using screw terminals positioned al ong the top and bottom , clearly accessible from the front for easy inst allation and servicing.
Crestron DIN-8SW8 DIN Rail High-Voltage Switch Applications The following diagram shows a DIN-8S W8 in a typical application. DIN-8SW8 in a Typical Application Operations & Installation Guide – DOC.
DIN Rail High-Voltage Switch Crestron DIN-8SW8 Specifications Specifications for the DIN-8SW8 ar e listed in the following table. DIN-8SW8 Specifications SPECIFICATION DETAILS Load Ratings Switch Channels 8 Maximum Per Channel 10 Amps incandescent, 5 Amps fluorescent, 0.
Crestron DIN-8SW8 DIN Rail High-Voltage Switch DIN-8SW8 Specifications (Continued) SPECIFICATION DETAILS Enclosure Light gray polycarbonate housing with polycarbonate label overlay, UL94 V-0 rated, 35.
DIN Rail High-Voltage Switch Crestron DIN-8SW8 Physical Description This section provides information on the connections, controls and indicators available on your DIN-8SW8. DIN-8SW8 Physical View DIN-8SW8 Overall Dimensions 58 mm (2.29 in) 59.5 mm (2.
Crestron DIN-8SW8 DIN Rail High-Voltage Switch Connectors, Controls & Indicators # CONNECTORS * , CONTROLS & INDICATORS DESCRIPTION 1 1 – 8 and LEDs (8) Sets of (2) captive screw terminals; Isolated Class 1 SPST relay switch circuits 1-8; Relay rating: 10 Amps incandescent 5 Amps fluorescent 16 Amps resistive 0.
DIN Rail High-Voltage Switch Crestron DIN-8SW8 Connectors, Controls & Indicators (Continued) # CONNECTORS * , CONTROLS & INDICATORS DESCRIPTION 4 SETUP (LED and BUTTON) (1) Red LED and (1) recessed miniature pushbutton for enabling setup mode and touch-settable ID 5 OVERRIDE with LEDs and BUTTON (2) 2-pin 3.
Crestron DIN-8SW8 DIN Rail High-Voltage Switch Industry Compliance This unit has been manufactured to comply with UL’s Standards for Safety in Canada and the United St ates.
DIN Rail High-Voltage Switch Crestron DIN-8SW8 Setup Network Wiring When wiring the Cresnet network, consider the following: • Use Crestron Certified Wire. NOTE: Cresnet HP cannot be used. • Use Crestron power supplies for Crestron equipment. • Provide sufficient power to the system.
Crestron DIN-8SW8 DIN Rail High-Voltage Switch • When the desired Net ID is displayed, press the SETUP button to exit the Setup mode. The SETUP LED extinguishes. NOTE: If an invalid Net ID is se t (00, 02, FF), “Er” will be displayed on the NET ID display.
DIN Rail High-Voltage Switch Crestron DIN-8SW8 The DIN-8SW8 is designed for insta llation on a DIN rail. Refer to the following diagram when installing. Installing the DIN-8SW8 DIN RAIL RELEASE DIN RAIL (NOT SUPPLIED) DIN-8SW8 TOP 1. Place the top of the DIN-8SW8’s rail mount over the top of the DIN rail.
Crestron DIN-8SW8 DIN Rail High-Voltage Switch Hardware Hookup Make the necessary connections as called out in the illustration that follows this paragraph. Refer to “ Network Wiring ” on page 10 before attaching the 4-position terminal block connector.
DIN Rail High-Voltage Switch Crestron DIN-8SW8 Hardware Connections for the DIN-8SW8 NET: TO CONTROL SYSTEM A ND OTHER CRESNET DEVI CES OVERRIDE: FROM DEVICE PROVIDING OVERRIDE S IGNAL & TO OTHER .
Crestron DIN-8SW8 DIN Rail High-Voltage Switch Programming Software Have a question or comment about Crestron software? Answers to frequently asked questi ons (FAQs) can be viewed in the Online Help section of the Crestron website. To post a question or view questions you have submitted to Crestr on’s True Blue Support, log in at http://support.
DIN Rail High-Voltage Switch Crestron DIN-8SW8 Programming with D3 Pro Crestron’s D3 Pro lighting software provides all the tools necessary to create a complete Crestron lighting sy stem for residential applications.
Crestron DIN-8SW8 DIN Rail High-Voltage Switch Locating the DIN-8SW8 in the Device Library • The system tree of the control sy stem disp lays the device in the appropriate slot with a default Net ID as shown in the following illustration.
DIN Rail High-Voltage Switch Crestron DIN-8SW8 • If necessary, double click a device to open the “Device Settings” window and change the Net ID, as shown in the following figure. “DIN-8SW8 Device Settings” Window • The ID code specified in th e SIMPL Windows program must match the Net ID of each unit.
Crestron DIN-8SW8 DIN Rail High-Voltage Switch Uploading and Upgrading Crestron recommends using the lat est programming software and that each device contains the latest firm ware to take advantage of the most recently released features. However, before atte mpting to upload or upgrade it is necessary to establis h communication.
DIN Rail High-Voltage Switch Crestron DIN-8SW8 Programs and Firmware Program or firmware files m ay be distributed from programmers to installers or from Crestron to dealer s. Firmware upgrades are available from the Crestron website as new fe atures are developed after product releases.
Crestron DIN-8SW8 DIN Rail High-Voltage Switch Operation NET ID Use the NET ID buttons to change the Net ID of the DIN-8SW8. For information on Net ID, refer to “ Identity Code ” which starts on page 10 . Manual Control The state of each output can be manua lly controlled from the front panel.
DIN Rail High-Voltage Switch Crestron DIN-8SW8 Save Override Settings The state of each output can be saved as an override setti ng, which can be automatically recalled when the Override mode is enabled. NOTE: The control system program has a setting that can prevent locally saving the override state.
Crestron DIN-8SW8 DIN Rail High-Voltage Switch Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative.
DIN Rail High-Voltage Switch Crestron DIN-8SW8 Check Network Wiring Use the Right Wire In order to ensure optimum perf ormance over the full range of your installation topology, Crestron Certifie d Wire and only Crestron Certifie d Wire may be used.
Crestron DIN-8SW8 DIN Rail High-Voltage Switch NOTE: All Crestron certified Cresne t wiring must consist of two twisted pairs. One twisted pair is the +24V conductor and the GND conductor and the other twisted pa ir is the Y conductor and the Z conductor.
DIN Rail High-Voltage Switch Crestron DIN-8SW8 Future Updates As Crestron improves functions, adds new features and extends the capabilities of the DIN-8SW8, additi onal information may be made available as manual updates.
Crestron DIN-8SW8 DIN Rail High-Voltage Switch Return and Warranty Policies Merchandise Returns / Repair Service 1. No m erchandise may be returned f or credit, exchange or service with out prior authorization from CR ESTRON. To obtain war ranty serv ice for CRESTRON products, contact an authorized CRESTRON deal er.
Crestron Electronics, Inc. Operations & Installation Guide – DOC. 6666A 15 Volvo Drive Rockleigh, NJ 07647 (2020748) Tel: 888.CRESTRON 05.08 Fax: 201.
Ein wichtiger Punkt beim Kauf des Geräts Crestron GreenLight DIN-8SW8 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Crestron GreenLight DIN-8SW8 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Crestron GreenLight DIN-8SW8 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Crestron GreenLight DIN-8SW8 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Crestron GreenLight DIN-8SW8 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Crestron GreenLight DIN-8SW8 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Crestron GreenLight DIN-8SW8 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Crestron GreenLight DIN-8SW8. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Crestron GreenLight DIN-8SW8 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.