Accor d Series T5/T8 Enhanced Lighting System.
1 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Visual Perception 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Comparison 7 . . . . .
2 Improve visual perception • The accord TM evenly distributes light, making the space more pleasing to the eye. • Dark spots (cave effect) associated with parabolics are eliminated. Attractive design • Smooth, cur ved surfaces are attractive but subtle.
Parabolics are designed to direct light into the cut-off zone, while restricting light into the shielded or glare zone. In other words, parabolics deliver light to the work plane and suppress high-angle brightness. Due to the high-angle cutoffs as shown in Figure 1.
SHIELDED ZONE CUT -OFF ZONE 85˚ 75˚ 65˚ 55˚ Figure 1. Parabolic Light Distribution MINIMIZED SHIELDED ZONE ENHANCED CUT -OFF ZONE 85˚ 75˚ 65˚ 55˚ Figure 2. accord TM Light Distribution Attractive contemporary design • Smooth, cur ved surfaces are attractive but subtle.
accord TM 2 Lamp, T5 accord TM (2) 28W T5 lamps, 18 fixtures step-dim electronic ballast (.95 ballast factor) 63 watts per fixture Watts/Sq.ft. Horizontal Footcandles Vertical Footcandles 0.76 41 25 IES* accord TM maximizes savings Choose either T5 or T8 technology to best meet your lighting needs.
T roffer 4 Lamp T ypical 4 lamp troffer (4) 32W T8 lamps, 12 fixtures electronic ballast (.87 ballast factor) 122 watts per fixture Watts/Sq.ft. Horizontal Footcandles Vertical Footcandles 0.98 50 23 IES* accord TM 2 Lamp, T8 accord TM (2) 32W T8 lamps, 12 fixtures electronic ballast (1.
Appearance and performance make accord TM the lighting choice. Energy savings makes accord TM a sound financial decision. The accord TM family of products saves up to 40% energy costs when compared to a standard 3 lamp,18 cell parabolic. The dimming feature reduces energy consumption by another 50%.
COST PER kWh Hours of Oper ation $0.06 $0.08 $0.1 0 $0.1 2 $0.1 4 P er Day P er Y ear 4L T8 3L T8 4L T8 3L T8 4L T8 3L T8 4L T8 3L T8 4L T8 3L T8 12 hrs. 4,380 $16.03 $7.88 $21.37 $10.51 $26.72 $13.14 $32.06 $15.76 $37.41 $18.36 18 hrs. 6,570 $24.04 $1 1.
• 3-13/16" low profile housing Surface Mount av ailable Low profile and quality performance – the surface accord TM is an energy efficient alternative to traditional surface mount fixtures. Designed for areas without a grid-ceiling type system, the accord’ s TM low profile is an ideal retro-fit solution.
Diffuser Options Square Perf Design (SQP) Smooth acrylic diffuser with square perforated insert (2' x 2', 2' x 4' only) Round Perf Design (RPD) Smooth acrylic diffuser with round p.
accord TM - 1' x 4', T5 accord TM - 1' x 4', T8 Candlepower Angle Along II 45° Across ⊥ 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 AC-128T5 Electronic Ballast (1) F28T5/835 Lamp 260 0 Lumens Spacing criterion: (II) 1 .
accord TM - 2' x 2', T5 accord TM - 2' x 2', T8 Candlepower Angle Along II 45° Across ⊥ 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 2AC-214T5 Electronic Ballast (2) F14T5/835 Lamps 1350 Lumens Spacing criterion: (II) 1 .
T5 Ordering Information SAMPLE NUMBER: 2AC-228T5-UNV-L5841-EBT1NDIM-U Number of Lamps (Not included) 1 =1 Lamp (1' x 4' only) 2 =2 Lamp (2' x 2', 2' x 4' only) W attage (.
• The accord TM can provide up to 40% energy savings when compared to a 3 lamp, 18 cell, T8 parabolic. • The accord TM also exceeds mandated energy regulations such as California’ s Titl e 24 and ASHRAE 90.1 2001. • Step dimming can increase energy s av ings by as much as 50%.
Printed in USA ADF080670 Cooper Industries, Ltd. 600 T ravis, Ste. 5800 Houston, TX 77002-1001 P: 713-209-8400 www .cooperindustries.com Cooper Lighting and Metalux logos are valuable trademarks of Cooper Industries in the United States and other countries.
Ein wichtiger Punkt beim Kauf des Geräts Cooper Lighting Accord Series (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Cooper Lighting Accord Series noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Cooper Lighting Accord Series - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Cooper Lighting Accord Series reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Cooper Lighting Accord Series erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Cooper Lighting Accord Series besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Cooper Lighting Accord Series verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Cooper Lighting Accord Series. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Cooper Lighting Accord Series gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.