Benutzeranleitung / Produktwartung CDIZC - P des Produzenten Continental
Zur Seite of 16
1 W415-0224 / D / 01.15.04 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Ba rrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .continentalfireplaces.com • ask@continentalfire.
2 W415-0224 / D / 01.15.04 Pg 2 -4 INTRODUCTION Warranty General Instructions General Information Care of Glass & Plated Parts 5 -7 INST ALLA TION Insert V ent Connection Chimney Connection Wall S.
3 W415-0224 / D / 01.15.04 CONTINENTAL gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. CONTINENTAL products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0224 / D / 01.15.04 FOR YOUR SA TISF ACTION, THIS FIREPLACE INSERT HAS BEEN TEST -FIRED TO ASSURE ITS OPERA TION AND QUALITY! Minimum inlet gas supply pressure is 4.
5 W415-0224 / D / 01.15.04 Pro vide adequate ventila tion air . Provide adequate accessibility clearance for ser vicing and operating the fireplace inser t. Never obstruct the front opening of the fire- place inser t. Objects placed in front of the fireplace must be kept a minimum of 48" away from the front face of the unit.
6 W415-0224 / D / 01.15.04 Move the insert close to its final position inside the wood- burning fireplace. This unit is equipped with 6 levelling screws located as follows: two are on either side of the circulation blower on the rear panel; four are located front and back on either side beneath the log support.
7 W415-0224 / D / 01.15.04 To adjust the trim: If the mitre is out of alignment, open each side and loosen the two screws at either side trim hinge. Slide the trim up or down to adjust and re-tighten screws. There is also a very slight in/out adjustment that can be made.
8 W415-0224 / D / 01.15.04 Positioning the logs improperly will cause flame im- pingement and carboning. PHAZER TM logs and glowing embers, exclusive to Continental Fireplaces, glow when exposed to direct flame and provide a unique and realistic glowing effect that is different in every installation.
9 W415-0224 / D / 01.15.04 The on-off switch is located behind the left side control door . Purge all gas lines with the glass door open. Assure that a continuous gas flow is at the burner before clos- ing the door . Allow several min utes (5-15) for the flame to stabilize after ignition.
10 W415-0224 / D / 01.15.04 1. Turn off the electrical power and the gas supply to the fireplace insert. 2. Remove the fire viewing door. Remove the logs. 3. Detach the two screws from the back of the firebox and remove the panel, as illustrated. 4. Remove the blower access door held on with the re- maining 8 screws.
11 W415-0224 / D / 01.15.04 Remove the pilot screw cap. Adjust the pilot screw to pro- vide properly sized flame. Turn in a clockwise direction to reduce the gas flow .
12 W415-0224 / D / 01.15.04 31* W690-0001 MILLIVOL T THERMOST A T 32* W660-0010 REMOTE CONTROL - ADV ANT AGE 32* W660-001 1 REMOTE CONTROL - ADV ANT AGE PLUS 33* GD660 REMOTE WALL SWITCH C / W 20FT WI.
13 W415-0224 / D / 01.15.04 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
14 W415-0224 / D / 01.15.04 Main burner goes out; pilot stays on. Pilot flame is not large enough or not engulfing the thermopile. Thermopile shorting Remote wall switch wire is too long, too much resistance in the system Faulty thermostat or switch - turn up pilot flame.
15 W415-0224 / D / 01.15.04 Exhaust fumes smelled in room, headaches. - check all seals. Fireplace is spilling. Carbon is being de- posited on glass, logs or combustion chamber surfaces. Flame is impinging on the logs or combustion chamber . - check that the logs are correctly positioned.
16 W415-0224 / D / 01.15.04 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Deale.
Ein wichtiger Punkt beim Kauf des Geräts Continental CDIZC - P (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Continental CDIZC - P noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Continental CDIZC - P - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Continental CDIZC - P reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Continental CDIZC - P erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Continental CDIZC - P besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Continental CDIZC - P verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Continental CDIZC - P. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Continental CDIZC - P gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.