O O W W N N E E R R ’ ’ S S M M A A N N U U A A L L M M O O D D E E L L L L M M 2 2 1 1 X X P P E E X X T T E E N N D D E E D D P P E E R R F F O O R R M M A A N N C C E E R R E E L L E E A A S S E E D D E E V V I I C C E E The Chamberlain Group, Inc.
When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical or from electric shock.
INTRODUCTION 3 AGENCY REQUIREMENTS Installation and testing to factory specifications shall be performed by factor y authorized personnel for proper operation in accordance with the latest National Fi.
4 INST ALL A TION Classification: Releasing device as defined by Underwriters Laboratories. Installation Requirements: Intended for “Indoor Dry” locations; all wiring must be per formed in accordance with the most current version of NFP A 72 - National Fire Alarm Code and the National Electric Code.
1 2 + 24Vdc from an Approved UL 1481 Regulated Power Supply with Battery Backup – 5 WIRING WIRING INSTRUCTIONS Verify wiring configuration with that recommended by door manufacturer for use of this product with specific door and accessories being utilized.
6 WIRING WIRING DIAGRAM 1 2 3 4 Solenoid (YE) (GY) R6 P2 U4 C2 U2 U3 C4 C1 Field Wiring shall consist of 22-18 A WG wiring. 1. Supervised, power limited circuit, 20 Ohm maximum line impedance. 2. Unsupervised, power limited circuit, 20 Ohm maximum line impedance.
7 CONNECTIONS OF INITIATING DEVICES AND ACCESSORIES A maximum of 4 smoke detectors may be installed with this device. Refer to NFP A 72 and NFP A 80 for instructions concerning proper placement and detection coverage. End-of-line devices must be installed for supervision of electrical power to 4-wire smoke detector .
8 WIRING 5 6 Fire Alarm Control Panel Red Black Common Normally Closed T erminal Strip Relay Module – + FIGURE 7 CONNECTIONS OF INITIATING DEVICES AND ACCESSORIES (cont’d) Relay Module Installation In lieu of smoke detectors, the release device may be put into alarm by the fire alarm control panel.
9 WIRING OPTIONAL CONNECTIONS (cont’d) DIP SWITCH SELECTION The release device will provide a factory default delay of 10 seconds (to minimize nuisance alarms) before releasing the fusible link chain upon alarm or power loss.
10 TESTING TEST PROCEDURES TO BE PERFORMED BY F ACTORY AUTHORIZED PERSONNEL ONL Y! CLEAR FIRE DOOR OPENING AND PROHIBIT TRAFFIC THROUGH DOOR OPENING WHILE TESTING! T esting does not affect normal operation of alarm system when connected to release device/control panel.
N/O Detector T rouble Y ellow (LED 4) If lit, indicates a trouble condition (a short) within the N/O 2-wire (or 4-wire) smoke detector loop (emanating from terminal board positions 3 and 4), resulting from either incorrect wiring or incorrect placement of the end-of-line resistor , and the smoke detector loop is inactive.
Disable Y ellow The Y ellow LED will light when the door reaches the close limit and activates a proximity switch attached to terminal positions 7 and 8 on the release device.
ACCESSORIES REPLACEMENT P ARTS 13 ACCESSORIES AND REPL ACEMENT P ARTS HOW TO ORDER REPAIR PARTS OUR LARGE SERVICE ORGANIZA TION SPANS AMERICA Installation and service information call our TOLL FREE nu.
LM2W-B 24Vdc 2-Wire Photo 2W-B LM2WT -B 24Vdc 2-Wire Photo with Thermal 2WT -B LM4W-B 24Vdc 4-Wire Photo 4W-B LM4WT -B 24Vdc 4-Wire Photo with Thermal & Form C Relay 4WT -B LM1424 24Vdc Ion #1424 .
15 OPERA TOR NOTES.
01-32046B © 2006, The Chamberlain Group, Inc. Issue Date 7/27/2006 All Rights Reserved.
Ein wichtiger Punkt beim Kauf des Geräts Chamberlain LM21XP (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Chamberlain LM21XP noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Chamberlain LM21XP - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Chamberlain LM21XP reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Chamberlain LM21XP erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Chamberlain LM21XP besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Chamberlain LM21XP verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Chamberlain LM21XP. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Chamberlain LM21XP gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.