T elephone entr y/access control sy s tem © 2008 The Chamberlain Group, Inc. All Rights Reser ved ® ™ ® ™ Ins t allation Manual for Ins t allation Manual for EL MODELS EL MODELS.
.
Table of Contents Page 1 Mounting the Unit Page Dimensions 2 EL25 Installation 3 Rotating the Keypad for Vertical Mounting 3 Unlocking/Locking EL2000 4 EL2000 Installation 5 Wire Type Wire Connections.
Page 2 Dimensions Dimensions Caution! A Static Discharge can Damage Circuit Boards 6 in. 3-15/16 in. Mounting Holes (4) for 5/16 in. 3/4 in. Conduit Hole 1-1/4 in. Conduit Hole Knockouts for 5/16 in. Knockouts for 3/8 in. 15 in. AUG 10, 2005 WELCOME 3-1/16 in.
Page 3 EL25 Installation EL25 Installation DO NOT overload the removable terminal block connectors. One wire per hole. DO NOT pinch wires when closing and locking the unit.
Page 4 Unlocking/Locking EL2000 Unlocking EL2000 1. Apply pressure to the right-side of the unit. 2. While maintaining pressure, turn key clockwise 3. Open cover Locking EL2000 1. Turn key counter clockwise to lock position 2. Close cover 3. Apply pressure to left-side until you hear a “click” sound 4.
Page 5 # 1 2 3 ? 4 5 6 7 8 9 * 0 # # # # # # 1 2 3 4 5 6 7 8 9 0 * # ? # # # # # EL2000 Model Installation EL2000 Installation 1 Unlock Unit 2 Open Cover 3 Unplug the 2 Main Harnesses (Optional) 4 Sli.
Page 6 Wire Connections to the Unit Input Board Connections 1. Door 1 Exit Request and Door Status 2. Door 2 Exit Request and Door Status 3. Door 3 Exit Request and Door Status 4. Door 4 Exit Request and Door Status 5. Postal Lock Input 6. AutoCall Input 7.
Page 7 Wire Specs and Run Distances Wire Specs and Run Distances Use this chart to pull wires in preparation of your installation: Power Wire Specs and Run Distances Description of Wire Run Grounding .
Page 8 Grounding the Units Grounding the Units Ensure that the system is grounded properly. The units contain a number of static sensitive components that can be damaged by static discharge. IMPORTANT: An Earth Ground Rod is Strongly Recommended and should be no further than 12 feet from the unit and use a minimum of 12 gauge wire in most cases.
Page 9 Wiring 1 Unit to Telco Line Wiring 1 Unit to Telco Line The bypass board allows the unit to be disconnected without interrupting normal telephone operation. NOTE: Installation where fiber optic phone lines are present may require additional modifications from your telephone provider.
Page 10 Wiring Multiple Units to Telco Line Wiring Multiple Units to Telco Line Up to 7 units can share the same phone line. The bypass boards allow the units to be disconnected without interrupting normal telephone operation.
Page 11 Wiring with No Telco Line Wiring with No Telco Line The unit can be a stand alone system that allows communication between the unit and a resident’s phones. Single Unit Tip Ring Tip Ring RES TELCO Use 18-24 AWG 2 twisted pair Output Board (See page 6) NOTE: Ringer Equivalence Number (REN) of “5” maximum.
Page 12 Wiring to Dedicated Telco Line Wiring to Dedicated Telco Line IO Output Board LED 2 LED 1 RELAY 1 RELAY 2 RELAY 3 RELAY 4 J3 J5 J4 J1 NO NC C NO NC C NO NC C NO NC C LED 4 LED 3 RES TELCO J6 J.
Page 13 Wiring to an Internal Phone System Wiring to an Internal Phone System The units can be wired to any Analog Trunk in an internal home phone system. NOTE: Installation where fiber optic phone lines are present may require additional modifications from your telephone provider.
Page 14 Connection To A NPBI System Connection To An NPBI System IO Output Board LED 2 LED 1 RELAY 1 RELAY 2 RELAY 3 RELAY 4 J3 J5 J4 J1 NO NC C NO NC C NO NC C NO NC C LED 4 LED 3 RES TELCO J6 J8 Tip.
Page 15 Wiring a Door Strike Lock/Maglock Wiring a Door Strike Lock Wiring a Maglock IO Output Board LED 2 LED 1 RELAY 1 RELAY 2 RELAY 3 RELAY 4 J3 J5 J4 J1 NO NC C NO NC C NO NC C NO NC C LED 4 LED 3 RES TELCO J6 J8 Use 18-22 AWG NOTE: The door strike can be connected to any of the 4 relays.
Page 16 Wiring a Gate Operator / Key Switch / PIR / REX Wiring a Gate Operator Wiring a Key Switch/PIR/REX Any auxiliary opening device such as a key switch or PIR (Passive Infrared Device), or an exit request button (REX) that provides normally open contact closure can be hooked up to the Door Input terminals.
Page 17 Wiring a Door Sensing Device / AutoCall Wiring a Door Sensing Device The units can monitor the position of up to four doors/gates and may react to a change in their status with one of the relays (not set as a control relay).
Page 18 Wiring a RF Module / Card Reader / Keypad Wiring a Radio Frequency Module An optional radio frequency module and a remote antenna can be installed if the residents will access a controlled area with a transmitter. Refer to instructions supplied with the optional RF Module for more information.
Page 19 Wiring a Postal Lock Switch / Internal Camera (CCTV) Wiring a Postal Lock Switch - EL25 Models Only The Post Office requires installation of a postal lock if postal carriers do not have access to a controlled area. Contact the local post office and arrange for them to install the postal lock while you are on site.
Page 20 Wiring Power to the Unit Wiring Power to the Unit The 110 VAC outlet must be dedicated to the unit ONLY . This outlet should be wired back to its own 10 Amp minimum circuit breaker. This will prevent two problems: • Other equipment cannot introduce spikes, noise, surges or dips into the power circuit.
Page 21 J500 H2 100A UD H2 100A UD 3D2 100 16B J406 LCD J201 MIC J403 D2 D102 D153 3D2 100 16B 3D2 100 16B 3D2 100 16B H2 100A UD 3D2 100 16B J400 + DEVICE 1,2 Description Type Used on Model 1 11 10 9 8 7 6 5 4 3 2 No.
Page 22 Troubleshooting Troubleshooting Wiring • Check for correct length and AWG of wires. See page 7. • Check that wires are correctly inserted into the terminal blocks (not loose, no two sharing the same position). • Check board markings for correct terminal block placements.
Page 23 Repair Parts Repair Parts Installation and Service Information is Available Call our Toll Free Number 1-800-528-2806 www.chamberlain.com 17 21 22 18 19 20 16 15 10 13 14 11 11 12 8 9 7 4 5 6 1.
Page 24 EL2000 Parts Repair Parts Repair Parts 8 1 2 3 4 6 7 5 16 17 20 9 19 13 12 21 18 22 14 10 15 23 When ordering repair parts, please supply the following information: Description and Model Numbe.
Page 25 Your System Diagram Your System Diagram.
Page 26 Your Wiring Configuration Your Wiring Configuration External Access Control Device(s) connected to optional board(s) Device 0 __________________________________________________________________.
Page 27 Accessories Accessories 0 0 4 J 0 0 2 J 2 0 4 J 6 0 4 J 1 0 2 J 7 0 4 J 4 0 4J 1 0 4 J 6 0 4 J 4 0 4J 1 0 4 0 0 4 J N O C I T I N U W E N e h t k c i l C . 1 t i n U r e t n E d n a e m a N e p y T t i n U 1 , y r t n u o C r e t n E y t i C d n a .
Page 28 FCC and DOC Requirements FCC and DOC Requirements FCC Requirements The units comply with Part 68 of the FCC Rules. The label affixed to this equipment contains, among other information, the FCC Registration Number and Ringer Equivalence Number (REN) for this equipment.
.
845 L arch Avenue Elmhurs t, Illinois 60125-1196 114A2980 F ® ™ © 200 8 The Chamberlain Group, Inc. All Rights Reser ved.
Ein wichtiger Punkt beim Kauf des Geräts Chamberlain EL MODELS (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Chamberlain EL MODELS noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Chamberlain EL MODELS - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Chamberlain EL MODELS reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Chamberlain EL MODELS erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Chamberlain EL MODELS besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Chamberlain EL MODELS verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Chamberlain EL MODELS. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Chamberlain EL MODELS gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.