1384 SHR cov er 5/27/99 djt SHR Series W oodburning Fireplace For Models: SHR36 SHR42A SHR48 SHR52 Underwriter's Laboratories Report No. MH6018 DO NOT DISCARD THIS MANUAL: Retain for future use.
2 SHR Series W oodbur ning Fireplace 20001384 Safety Information PLEASE READ THIS MANUAL BEFORE INST ALLING AND USING FIREPLACE. IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty .
3 SH R Series W oodb urning Fireplaces 20001384 Rough Opening Height 42" (1067mm) 52 " (1327mm) 48 " (1222mm) " " 28 " (724mm) " (189mm) 13 " Dia.
4 SHR Series W oodbur ning Fireplace 20001384 " (724mm) 7 " (197mm ) 48" (1219mm) 58 " (1480mm) 48 " (1232mm) " " " (189mm) 13 " Dia.
5 SH R Series W oodb urning Fireplaces 20001384 FP554A SH Series 1/28/99 djt Chase Installation Insulation methods shown are optional for cold climate, not a requirement for unit operation. FP554A Fig. 5 Fireplace and chase parts identification.
6 SHR Series W oodbur ning Fireplace 20001384 Chimney Requirements - Offset Installations 0 0 0 0 0 3" 1 1" 1 0 0 0 0 8 ¹⁄₄ " 20" 0 1 0 0 0 1 1 ¹⁄₄ " 25 ¹⁄₄ &qu.
7 SH R Series W oodb urning Fireplaces 20001384 Planning Information The T en Foot Rule Major U.S. building codes specify a minimum chimney height above the roof top.
8 SHR Series W oodbur ning Fireplace 20001384 Installation Chimney Supports The chimney system is supported by the fireplace for vertical chimney heights less than 30 feet above the hearth. Chimney supports are required if the vertical height exceeds 30 feet with 1 1CF chimneys.
9 SH R Series W oodb urning Fireplaces 20001384 Framing Framing can be constructed before or after the fireplace is set in place, however , most installers build the frame before setting the fireplace. Frame fireplace with 2 x 4 lumber or heavier materials.
10 SHR Series W oodbur ning Fireplace 20001384 FP556SHR Fig. 13 Locate centerline of chimney with plumb line. FP556SHR SHR LOCA TE CENTER LINE 5/11/99 djt Chimney Centerline Actual Centerpoin.
1 1 SH R Series W oodb urning Fireplaces 20001384 The inside dimension of the frame must be the same as the hole size selected from Figure 1 1 in order to provide the required 2 inches of air space between the outside diameter of the chimney and the edges of the framed ceiling hole.
12 SHR Series W oodbur ning Fireplace 20001384 Installing the Chimney System Start by attaching the first chimney section to the collar on top of the fireplace. Install the pipe as pictured in Figure 19. When you get a good lock, you will hear the pipe clearly snap together .
13 SH R Series W oodb urning Fireplaces 20001384 Attic Installation Ceiling Installation Fig. 21 Installing firestop spacer . FP285 IWF285 mbuf 5/25/96 Nails (4) Firestop Spacer Joist J.
14 SHR Series W oodbur ning Fireplace 20001384 Cut and Frame Roof Hole Size of roof hole varies with the type of chimney termi- nation installed. Refer to installation instructions pro- vided with the chimney termination to find correct size roof hole.
15 SH R Series W oodb urning Fireplaces 20001384 FP1166 surround flush with finished wall 12/20/01 djt Stud 2 x 4 Header Ledge Bracket Surround Must be Sealed with Noncombustible Material Noncombus- tible Decorative Facing Finished W all FP1 166 Fig. 26 Fireplace surround flush with finished wall.
16 SHR Series W oodbur ning Fireplace 20001384 FP1167 facing flush with finished wall 12/20/01 djt Finished W all Stud Noncombustible Decorative Fac- ing Must be Sealed with Noncombustible Material Surround 2 x 4 Finished Header Covered W all Ledge Bracket FP1 167 Fig.
17 SH R Series W oodb urning Fireplaces 20001384 Side W all Protection Adjacent combustible side walls that are within dimen- sions shown in Figure 30 of fireplace opening must be protected with W all Shield Model SP40 or a specifically built wall shield described in Figure 29.
18 SHR Series W oodbur ning Fireplace 20001384 FP532SHR Fig. 32 Combustible side wall protection and hearth extension dimensions. Minimum W all Clearances WITH Noncombustible Surround Facing WITHOUT N.
19 SH R Series W oodb urning Fireplaces 20001384 removed from gas line tube to repack space around the pipe. Material should be inserted from outside of the fireplace and packed tightly to totally seal between the pipe and tube.
20 SHR Series W oodbur ning Fireplace 20001384 1384 pts replacement parts 5/27/99 djt 7/14/99 removed clips,added push nut 1 2 3 4 5 6 7 8 a b c 9 10 1 1 d 12 13 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
21 SH R Series W oodb urning Fireplaces 20001384 Description Designed to enclose the fireplace opening with glass doors allowing the fire to remain visible. Available in Polished, Brushed Brass, Black and Pewter Provides outside air for fuel conbustion in the firebox.
22 SHR Series W oodbur ning Fireplace 20001384 Accessory Description Model No. Contemporary Flashing Contemporary Chase T op T ermina- tion Contemporary Round T op T ermina - tion Extended Round T op .
23 SH R Series W oodb urning Fireplaces 20001384 LIMITED W ARRANTY & 30 YEAR PROTECTION PLAN For MAJESTIC FIREPLACES ® PRE-ENGINEERED Fireplace Systems CFM Corporation warrants its MAJESTIC FIREP.
© CFM Corporation 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www .cfmcorp.com CFM Corporation.
Ein wichtiger Punkt beim Kauf des Geräts CFM Corporation SHR52 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie CFM Corporation SHR52 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für CFM Corporation SHR52 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von CFM Corporation SHR52 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über CFM Corporation SHR52 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon CFM Corporation SHR52 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von CFM Corporation SHR52 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit CFM Corporation SHR52. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei CFM Corporation SHR52 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.