INST ALLER / CONSUMER SAFETY INFORMA TION 30002008 7/04 Rev . 3 PLEASE READ THIS MANUAL BEFORE INST ALLING AND USING APPLIANCE. W ARNING! IF THE INFORMA TION IN THIS MANUAL IS NOT FOLLOWED EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROP- ERTY DAMAGE, PERSONAL IN- JUR Y OR LOSS OF LIFE.
2 2 Dutchwest Natural Vent Gas Heater 30002008 PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Dutchwest stove. IMPORTANT: Read all instructions and warnings carefully before starting installation.
3 Dutchwest Natural Vent Gas Heater 30002008 The Dutchwest Natural V ent Room Heater , Model Nos. 2467 and 2468, is a vented gas appliance listed to the ANSI standard Z21.88b-2001 and CSA-2.33b-2001 for V ented Room Heaters, and CSA 2.17-M91, Gas-Fired Appliances For Use at High Alti- tudes.
4 4 Dutchwest Natural Vent Gas Heater 30002008 C L V alve Inlet C L V alve Inlet 17" (419mm) 23" (584mm) 28 ³⁄₈ " (721mm) 4 ³⁄₈ " (1 1 1mm) 6 ³⁄₄ " (172mm) 12 ¹⁄₂ " (318mm) 24 ¹⁄₂ " (622mm) See Page 5 for Flue Collar Centerline Dimensions.
5 Dutchwest Natural Vent Gas Heater 30002008 Clearance Requirements Minimum Clearances to Combustible Materials Measure side clearances as shown in Figures 2 through 5 from the outer edge of the cast iron stove top. Measure rear clearances from the outermost surface of the sheet metal rear skirt.
6 6 Dutchwest Natural Vent Gas Heater 30002008 Venting Requirements and Options The Dutchwest must be properly connected to a listed 4” (100mm) Type B venting system or to an approved Class A masonry or factory-built chimney system. In Canada, a complete relining of Class A chimney systems is required.
7 Dutchwest Natural Vent Gas Heater 30002008 Passing Through a Combustible Wall or Ceiling An approved pass-through device is always required when a vent passes through a combustible wall or ceiling. Check with the maker of the vent system for the correct listed devices that are available.
8 8 Dutchwest Natural Vent Gas Heater 30002008 Outer Shroud Slot Inner Shroud Slot ST194 Fig. 11 Position the fan to engage the inner shroud with the fan bracket slots and secure with sheet metal screws. Left Air Duct Fan Inner Shroud ST720 Fig. 10 Attach snapstat wire assembly to inside of inner shroud with clamp screws.
9 Dutchwest Natural Vent Gas Heater 30002008 Snapstat Left Air Duct ST671 Fig. 12 Install the snapstat and connect the extension wire terminals. View is with top removed, however, access is available through the rear when installing fan before gas line connection.
10 10 Dutchwest Natural Vent Gas Heater 30002008 Connect the Gas Supply Line Check the Rating Plate attached by a steel cable to the firebox, to confirm that you have the appropriate firebox for the type of fuel to be used. The Dutchwest may be converted from one gas to another using the appropri- ate Fuel Conversion Kit listed on Page 23.
11 Dutchwest Natural Vent Gas Heater 30002008 Burner Information The appliance must only use the gas specified on the rating plate, unless converted using a CFM Specialty Home Products Fuel Conversion Kit. Refer to Page 23 for the correct Fuel Conversion Kit for your model.
12 12 Dutchwest Natural Vent Gas Heater 30002008 Install the Stove Front Insert the handle stub into the hole in the front casting. Fasten in place with the 3/8” locking nut provided. (Fig. 23) The front attaches to the stove by four steel tabs that engage with corresponding cast ribs onto the sides and bottom of the stove body .
13 Dutchwest Natural Vent Gas Heater 30002008 Operation Your First Fire Read these instructions carefully and familiarize yourself with the burner controls.
14 14 Dutchwest Natural Vent Gas Heater 30002008 3. Open control access panel. 4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. Turn off all electrical power to the fireplace.
15 Dutchwest Natural Vent Gas Heater 30002008 A. Defective or misaligned Using a match, light [ilot. If pilot lights, turn off pilot and electrode at the pilot push the ignitor button again. If pilot will not light, check gap at electrode and pilot - it should be 1/8” to have a strong spark.
16 16 Dutchwest Natural Vent Gas Heater 30002008 Conversion Precautions Conversion must be completed only by qualified personnel. Before proceeding, turn control knob on valve to “OFF” and turn gas supply OFF . T urn OFF any electricity that may be going to the appliance.
17 Dutchwest Natural Vent Gas Heater 30002008 Pilot Hood Pilot Bracket CO105a Fig. 31 Remove pilot hood. Index T ab Snap Ring Allen Wrench CO106a Fig. 32 Remove pilot orifice. • Remove pilot orifice with allen wrench. (Fig. 32) • Install the conversion orifice.
18 18 Dutchwest Natural Vent Gas Heater 30002008 Conversion to LP Input (BTU/h) Air Shutter Kit # Front Part # Rear Part # Minimum Maximum Setting 000-5022 #69 / .
19 Dutchwest Natural Vent Gas Heater 30002008 Maintenance Y our Dutchwest Gas Heater will provide years of service with minimal upkeep. The following procedures will help ensure that your stove continues to function properly . Annual System Inspection Have the entire heater and venting system inspected annually by a qualified gas technician.
20 20 Dutchwest Natural Vent Gas Heater 30002008 Gasket Replacement The Dutchwest Gas Heater uses a ‘tadpole’ type gasket to seal between the glass panel and the frame. In time, this gasket can become brittle and compressed and should be replaced.
21 Dutchwest Natural Vent Gas Heater 30002008 NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUP- PLIED WITH THE APPLIANCE, MUST BE RE- PLACED, IT MUST BE REPLACED WITH TYPE SF- 2, 200 ° C WIRE OR ITS EQUIV ALENT .
22 22 Dutchwest Natural Vent Gas Heater 30002008 Dutchwest Natural V ent Gas Heater Models 2467, 2468 Ref. Description Part Number 1. SDV30 Log Set Assembly 20003458 1a. Rear Log 20003459 1b. Right Log 20003460 1c. Left Log 20003461 2. Small Lava Rock Package 57897 3.
23 Dutchwest Natural Vent Gas Heater 30002008 Dutchwest Natural V ent Gas Heater (continued) Models 2467, 2468 Ref. Description Part Number 6. Door , DW Gas 30001929 7. Leg, DW Gas 30001930 8. End, Rt - DW Gas 30001927 9. End, Lt - DW Gas 30001926 10.
24 24 Dutchwest Natural Vent Gas Heater 30002008 Decorative Rings 4” brass or black rings are available to add a decorative touch to the exposed stove pipe.
25 Dutchwest Natural Vent Gas Heater 30002008.
26 26 Dutchwest Natural Vent Gas Heater 30002008 BASIC WARRANTY CFM Specialty Home Products Company (hereinafter referred to collectively as the Company) warrants that your new Dutchwest Gas Fireplace.
27 Dutchwest Natural Vent Gas Heater 30002008 GARANTIE DE BASE La société CFM Specialty Products (ci-après la « Société ») garantit votre nouveau poêle/foyer au gaz Dutchwest contre tous défa.
© CFM Specialty Home Products 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www.majesticproducts.com • www .vermontcastings.
Ein wichtiger Punkt beim Kauf des Geräts CFM Corporation 2467, 2468 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie CFM Corporation 2467, 2468 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für CFM Corporation 2467, 2468 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von CFM Corporation 2467, 2468 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über CFM Corporation 2467, 2468 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon CFM Corporation 2467, 2468 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von CFM Corporation 2467, 2468 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit CFM Corporation 2467, 2468. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei CFM Corporation 2467, 2468 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.