Benutzeranleitung / Produktwartung FP-QUAD-510 des Produzenten National Instruments
Zur Seite of 12
FieldPoint™, Nat ional Instruments™, and ni. com™ are trademarks of National Instrument s Corporation. Product and company names mentione d herein are trademarks or trade names of their respective companies. 322633B-01 © Copyright 20 00 National Inst ruments Corp.
FP-QUAD-510 2 www.ni.com When defin ing a FieldPoint system that uses an FP-QU AD-510 module, you must calculate the power consu mption. First refer to the specifications section in the user man ual for your network module. The maximum number of terminal bases per bank multiplied by 1 watt is the total po wer the network module can supply .
© National Instruments Corp. 3 FP-QUAD-510 Figure 1. Install Y our Module Field Wiring The terminal base provides connections for each axis and for an external supply to po wer the FP-QU AD-510 input channels and field de vices. The FP-QU AD-510 accepts two types of encoder signal inputs: single-ended (TTL) or differential line dri ver .
FP-QUAD-510 4 www.ni.com Figure 3. Basic Field Connections to Single-Ended Encoders The FP-QU AD-510 supports differential inputs for Phase A, Phase B, and Index signals. Y ou can easily accommodate encoders with various phase relationships b y sw apping the signals and/or connecting them to the in verting inputs as specific applications require.
© National Instruments Corp. 5 FP-QUAD-510 T erminal assignments and wiring diagrams are also listed under the slide-in card on the front of the FP-QU AD-510 module. Status Indicators Figure 5 show s the module label and status indicators. Remov e the slide-in card to see wiring diagrams for the input signals.
FP-QUAD-510 6 www.ni.com Position Counter Operation Each position counter has a 32-bit binary counter th at represents the current position of the shaft connected to the axis. Channels 0 through 3 contain the lo west 16 bits of these counters f or axes 0 through 3 respecti ve ly .
© National Instruments Corp. 7 FP-QUAD-510 Reset on Index Capability Y ou can configure each position counter to reset each time the index condition is met. An index-initiated reset resets both the upper and lo wer 16-bit reg ister s associated with that axis.
FP-QUAD-510 8 www.ni.com The vel oci ty range is the ma ximum v elocity that can be measured for a gi ven timebase. The velocity re gister uses a 15-bit counter , which giv es a maximum number of counts of 2 15 , or 32,768.
© National Instruments Corp. 9 FP-QUAD-510 Note If the axis is stopped with the index condition true, then reading the status bit causes the bit to reset to 0. Howe ver , since the index condition is still true, the bit is immediately latched back to 1.
FP-QUAD-510 10 www.ni.com • As with any hazardous voltage wiring, mak e sure that all wiring and connection s meet applicable electrical codes and common sense practices. Mount terminal bases in an area, position, or cabinet that pre vents accidental or unauthorized access to wiring that carries hazar dous voltages.
© National Instruments Corp. 11 FP-QUAD-510 Specifications The following specif ications are typical for a range of –40 to +70 °C, unless otherwise noted. Encoder Input Number of channels ............ ............. . 4 Input type Single-ended ....
CE Mark Compliance This product meets applicable EU directi ve(s), as follo ws: Safety isolation ................................ EN 61010 (double insulation for 250 Vrms working isolation, installation category I I) EMC directi ve Immunity ..........
Ein wichtiger Punkt beim Kauf des Geräts National Instruments FP-QUAD-510 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie National Instruments FP-QUAD-510 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für National Instruments FP-QUAD-510 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von National Instruments FP-QUAD-510 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über National Instruments FP-QUAD-510 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon National Instruments FP-QUAD-510 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von National Instruments FP-QUAD-510 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit National Instruments FP-QUAD-510. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei National Instruments FP-QUAD-510 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.