Benutzeranleitung / Produktwartung KJ3FC des Produzenten Frymaster
Zur Seite of 88
NON-CE & Frymaster, a member of the Co mmercial Food Eq uipment Service Asso ciation, recomm ends using CFESA Certified Tec hnicians. 24-Hour Service Hotline 1-800-551-8633 APRIL 2005 PRINTED IN THE USA www.
ii Please read all sections of this manual and retain for future reference. NOTICE This appliance is intended for professional use only and is to be operated by qualified personnel only. A Frymaster Factory Authorized Service Center (FASC) or other qualified professional should perform installation, maintenance, and repairs.
iii DANGER Instructions explaining procedures to be followed MUST be posted in a prominent location in the event the operator detects a gas leak. This information can be obtained from the local gas company or gas supplier.
iv Master Jet CF Series Atmospheric Gas Fryers TABLE OF CONTENTS PAGE # 1. 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.8.1 1.8.2 1.8.3 1.8.4 1.8.5 1.8.6 1.8.7 1.8.8 1.8.9 1.8.10 1.8.11 1.8.12 1.9 1.9.1 1.9.2 1.9.3 1.9.4 1.9.5 1.9.6 1.9.7 1.10 1.10.1 1.10.2 1.11 1.
v Master Jet CF Series Atmospheric Gas Fryers TABLE OF CONTENTS (cont.) PAGE # 1.12.6 2. 2.1 2.2 2.3 2.3.1 2.3.2 2.4 2.5 2.5.1 2.5.2 2.5.3 2.6 2.7 2.7.1.1 2.7.1.2 2.7.2 2.7.3 2.7.4 2.7.5 2.7.6 2.7.7 2.7.8.1 2.7.8.2 2.7.9 2.8 2.9 A. A.1 A.1.1 A.1.2 A.1.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-1 1.1 Functional Description Master Jet (MJ) CF Series Atmospheric gas fryers contain a welded stainle ss steel frypot that is directly heated by gas flames that are diffused evenly over its lower surface by ceramic targets.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-2 1.1 Functional Description (cont.) CONTROL OPTIONS MJCF Series gas fryers may be equipped with th ermostat controllers or Computer Magic III.5 computers. KJ3FC variants are equipped with user-supplied or KFC-1 computers.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-3 1.1 Functional Description (cont.) Te s t Me te r S et t i ng P i ns Res ul t s 12 V A C P ower t o Cont rol l er 50 V A C.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-4 1.1 Functional Description (cont.) MJCFE Series fryers equipped with computers have a temperature probe . In these units, the probe resistance varies directly with the temperature.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-5 1.3 Checking Burner Manifold Gas Pressure WARNING This task should be performed by qualified service personnel only. 1. Ensure that the gas valve knob or button is in the OFF position.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-6 1.3 Checking Burner Manifold Gas Pressure (cont.) Non-CE Standard for Incoming Gas Pressures Gas Minimum M aximum Natural 6" W . C. 1.49 kPa 14.93 mbar 14" W .C. 3.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-7 1.5 Cleaning Gas Valve Vent Tube 1. Carefully unscrew the vent tube from the gas valve. NOTE : The vent tube may be straightened for ease in removal. 2. Pass a piece of ordinary binding wire (.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-8 1.7 Calibrating Thermostat Control 1. Fill the frypot to the lower OIL-LE VEL line with oil. If solid sho rtening is used, it m ust be tightly packed into the frypot. 2. Light the pilot.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-9 1.7 Calibrating Thermostat Control (cont.) 13. Close the fryer control panel and replace the screws in the upper corners. 14. Reinstall the thermostat knob with its pointer aligned with the 325°F (163°C) index m ark on the temperature dial.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-10 1.8.2 Replacing Op erating Thermostat CAUTION The thermostat must be calibra ted after in stallation is comp lete. Refer to Section 1.7 for calibration instructions. When handling the thermostat, do not rotate the shaft more than two turns in either direction.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-11 1.8.3 Replacing Temperature Probe 1. Disconnect the fryer from the electrical supply. 2. Drain the frypot. 3. Remove the screws from the upper left and right corners of the control panel.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-12 1.8.4 Replacing High-Limit Thermostat – Operating Thermostat Controls (cont.) 6. Unscrew the high-limit thermostat from the frypot and remove. 7. Apply Loctite PST567 thread sealant or equivale nt to th e replacem ent thermostat threads.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-13 1.8.6 Replacing Heat Mode Indicator Light – Operating Thermostat Controls 1. Disconnect the fryer from the electrical supply. 2. Loosen the setscrew securing the thermo stat knob and remove the knob.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-14 1.8.8 Replacing Melt Cycle Timer – Operating Thermostat Controls The mechanical melt cycle timer is no longer available. A solid-state timer replaces the mechanical unit.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-15 1.8.9 Replacing Burner Ceramic Targets DANGER Drain the frypot or remove the handle from the drain valve before proceeding further. 1. Disconnect fryer from elect rical and gas supplies.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-16 1.8.9 Replacing Burner Ceramic Targets (cont.) 10. To replace only the ceramic targets, straighten the target locking ta bs with a pair of needle nose pliers or a screwdriver, and slid e th e target up and off the bracket .
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-17 1.8.10 Replacing Gas Valve DANGER Drain the frypot or remove the handle from the drain valve before proceeding further. 1. Disconnect fryer from el ectrical and gas supplies 2.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-18 1.8.11 Replacing Pilot Assembly or Thermopile (cont.) 3. To replace the complete pilot assem bly: a. Disconnect the pilot tubing from th e bottom of the pilot assembly. b. Remove the screw from the pilo t mounting-bracke t to release the pilot assembly.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-19 1.8.12 Replacing Frypot (cont.) 13. Remove the cover from the safe ty drain switch, disconnect the wires from the switch, and pull them out of the switch box.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-20 1.9 Troubleshooting and Problem Isolation Because it is not feasible to attempt to include in this m anual every conceiva.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-21 1.9.1 Pilot/Ignition Failures (cont.) Ignition failures occur when the 24VAC power supply to the gas valve is interrupted, when the gas supply is interrupted, or when th e pilot flame is extinguished.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-22 1.9.2 Improper Burner Functioning The burner ignites but exhibits a bnormal characteristics such as "popping", incom plete lighting of the burner, fluctuating flame intensity, a nd flames "rolling" out of the fryer.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-23 1.9.2 Improper Burn er Functioning (cont.) Fluctuating flame intensity is no rmally caused by either im proper or fluctuating incom ing gas pressure, but may also be the result of variations in the kitchen atmosphere.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-24 1.9.3 Improper Temper ature Control (cont.) MELT CYCLE PROBLEMS NOTE: In early 1999, PC board melt cycle timers replaced melt-cycle timer motors in new fryers. See Section 1.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-25 1.9.4 Computer-Related Problems (cont.) Recovery Time Recovery time is a method of measuring a fryer’s perform a nce. Put simply, it is the time require d f or the fryer to increase the oil tem perature from 250°F to 300°F (121° C to 149°C).
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-26 1.9.5 Filtration Problems The majority of filtratio n problems arise f rom operator erro r. One of the most common errors is placing the filter paper on the bottom of the f ilte r pan rather than over the f ilter screen.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-27 1.9.5 Filtration Problems (cont.) Incorrectly sized or installed pa per will also allow food particles and sedim ent to pass through and clog the suction tube on the bottom of the filter ca rriage.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-28 1.9.6 Leakage Leakage of the frypot is mostly due to imprope rly sealed high-limits, th ermostats/tem perature probes, and drain fittings. When installed or repl aced, each of these components m ust be sealed with Loctite PST567 sealant or equivalent to prevent leak age.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-29 Optional ON-OF F switch High-Limit Thermostat Operating Thermostat Pilot Generator FENWALL Operating Thermostat HONEYWELL 1/2 P.S.I. HONEYWELL 1/2 PSI OFF ON P I L O T C H O N E Y W E L L 1/2 P S I P i l o t A d j.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-30 ROBERTSHAW-UNITROL 7000 SYSTEM CHECK 1. Complete System Check With thermostat contacts closed and gas cock dial in the “ON” position, the main burner should ignite. Measure the readin g between the 2 & 3 terminals.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-31 1.10 Troubleshooting Guides The troubleshooting guides f ound in the pages that follow are inte nded to assist service technicians in quickly isolating the probable causes of equipment m alfunctions by following a logical, step-by- step process.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-32 1.10.1 Initial Troubleshooting, Mi llivolt Frying Systems (cont.) PROBLEM PROBABL E CAUSES CORRECTIVE ACTION A. Inadequate m ake -up air in cooking area. A. Adjust ventilation system to increa se make-up air.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-33 1.10.2 Initial Troubleshooti ng, 24VAC Frying Systems PROBLEM PROBABL E CAUSES CORRECTIVE ACTION Burner won’t ignite. Light in ON/OFF switch is not illuminated. A. ON/OFF switch is off.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-34 1.10.2 Initial Troubleshooting, 24VAC Frying Systems (cont.) PROBLEM PROBABLE CAUSE CORRECTIVE ACTION A. Incoming gas supply pressures are not within range [Natural- 6-14" W.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-35 1.12 Wiring Diagrams 1.12.1 MJCF Millivolt Wiring Diagram, Non-CE 8050438C HONEYWELL 1/2 P.S .I . 1/2 P.S.I. HONEYWE LL OFF ON P I L O T C H O N E Y W E L L 1/2 P.S.I. A D J.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-36 1.12.2 MJCF Millivolt Wiring Diagram, CE FENWALL OPERATING THERMOSTAT 8050531A PILOT G ENERATOR (THERMOCOUPLE) MAIN VALVE.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-37 1.12.3 MJCFE 24V Wiring Diagram 24 VAC 7P or 240 VAC 6C C 2 1 6P 1/2 P.S .
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-38 1.12.4 MJCFEC 24V Wiring Diagram 12VAC 11 11 10 4 5 7 9 9 7 4 5 10 C C C D4 3 1 13 21 4 2 14 1 13 3 24VAC 12VAC D2 D1 D3 .
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-39 1.12.5 FAST-Ready Constant Pilot.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1-40 1.12.6 Filter Magic II Wiring Diagram FOR (DIRECT ) UNIT S 100V 200V OR 220V 120V 208V 35C 12 32C HEATER PUMP 8 7C 9 10 2.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-1 2.1 Accessories 1 2 3 4 5 6 7 8 9 10.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-2 2.1 Accessories (cont.) ITEM STANDARD PART # EURO-LOOK PART # COMPONENT 1 Gas Line, Dormont, With Quick-Di sconnect 806-1698SP 1" x 36" (2.54 cm x 91.4 cm) 806-1699 1" x 48" (2.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-3 2.2 Burner Manifold Components ITEM STANDARD PART # EURO-LOOK PART # COMPONENT 1 806-0225SP Deflector Assembly (Ceramic Target Ass.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-4 2.2 Burner Manifold Components (cont.) ITEM STANDARD PART # EURO-LOOK PART # COMPONENT 5 Pilot Assembly 810-2071 Natural Gas, w/Th.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-5 2.3 Cabinetry Components 2.3.1 Fryer Cabinetry 1 3 2 4 6 7 8 9 10 11 12 13 14 15 16 17 18 5 19 20 ITEM STA NDARD PART # EURO-LOOK .
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-6 2.3.1 Fryer Cabinetry (cont.) ITEM STANDARD PART # EURO-LOOK PART # COMPONENT 3 900-736 7SP 201-6916 Side, Left & Right - MJCF.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-7 2.3.2 Filter Magic II & Spreader Cabinet Cabinetry 1 2 3 4 5 6 7 8 9 10 11 12 13 15 14 16.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-8 2.3.2 Filter Magic & Spread er Cabinet Cabinetry (cont.) ITEM STANDARD PART # EURO-LOOK PART # COMPONENT 1 201-0486SP 201-6964.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-9 2.4 Casters, Legs and Associated Hardware 1 2 3 4 5 6 ITEM STANDARD PART # EURO-LOOK PART # COMPONENT 1 810-0356 Caster, Swivel, 5.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-10 2.5 Component Shield, Filter Box Assemblies and Components 2.5.1 Component Shield Assemblies – No Interface Board Component Shi.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-11 2.5.1 Component Shield Assemblies – No Interface Board (cont.) ITEM STANDARD PART # EURO-LOOK PART # COMPONENT 826-1546 806-962.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-12 2.5.2 Component Shield Assembli es – With Interface Board (cont.) ITEM STANDARD PART # EURO-LOOK PART # COMPONENT Co mplete Shi.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-13 2.5.3 Filter Box Assemblies (cont.) ITEM STANDARD PART # EURO-LOOK PART # COMPONENT 1 823-1584 Box, Control- FMCF Filter * 823-15.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-14 2.6 Control Panel Assemblies and Related Components (cont.) ITEM STANDARD PART # EURO-LOOK PART # COMPONENT 1 806-4992SP 106-4055.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-15 2.6 Control Panel Assemblies and Related Components (cont.) ITEM STANDARD PART # EURO-LOOK PART # COMPONENT * 806-2071 Harness, C.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-16 2.7.1.1 Filter Magic Drain Manifold Components (cont.) ITEM STANDARD PART # ** COMPONENT 1 900-0757 Cover, Drain End, Square Drain- FMCF 2 816-0032 Gasket, Flange, Square Drain- FMCF 3 823-0717 Tube, Square Drain- 2-½ x 15.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-17 2.7.1.2 Euro-Look Drain Manifold Components 7 6 3 4 5 2 1 8 9 ITEM EURO-LOOK PART # ** COMPONENT 1 823-4764 Drain Tube, Left End .
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-18 2.7.2 Filter Magic II Filter Pa n Components – Outer Pan Components 1 2 3 4 5 6 7 8 9 7 10 11 12 13 14 15 8 7 10 16 17 18 19 20.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-19 2.7.2 Filter Magic II Filter Pan Components – Outer Pan Components (cont.) ITEM STANDARD PART # EURO-LOOK PART # COMPONENT 12 8.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-20 2.7.3 Filter Magic Filter Pan Compon ents – Inner Pan Components (cont.) ITEM STANDARD PART # EURO-LOOK PART # COMPONENT * 806-.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-21 2.7.4 Oil Return Handle Component s – Units Built Prior To April 2001 1 2 3 3 4 5 6 7 8 9 11 11 12 13 14 15 16 10 12 12 13 14 1.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-22 2.7.5 Oil Return Handle Components –Units Built April 2001 and After 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 ITEM STAND.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-23 2.7.6 Oil Return Plumbing FLEX LINE TO NEX T POT (WHERE AP PLICABLE) OIL RETURN PLUMBING FILTER MAGIC II (TY PICAL) 1 2 3 4 5 7 8.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-24 2.7.7 Filter Pump and Motor Components 1 2 3 4 5 6 7 8 9 11 14 13 15 12 6 16 17 18 10 ITEM STANDA RD PART # EURO-L OOK PART # COM.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-25 2.7.7 Filter Pump and Motor Components (cont.) ITEM STANDARD PART # EURO-LOOK PART# COMPONENT 6 813-0062 Elbow, ½" 90° NPT.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-26 2.7.8.1 Drain Valves and Related Components 1 2 3 4 5 6 7 8 9 10 11 12 ITEM STANDARD PART # ** COMPONENT 1 806-4145 Valve, Drain-.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-27 2.7.8.2 Euro-Look Drain Valves a nd Related Components-Round Drains ITEM EURO-LOOK PART # ** COMPONENT 106-3760 Valve, Drain Asse.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-28 2.7.9 Power Shower Components 1 2 3 4 ITEM STA NDARD PART # EURO-LOOK PART # COMPONENT 806-4529SP Power Shower Assembly, Full Vat, Complete 1 809-0415 Screw, Cleanout 2 814-0001 Grip, Handle 3 826-1390 Seal (Gasket) (Qty: 5) 4 826-1344 O-Ring (Qty: 5) * Not illustrated.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-29 2.8 Frypot, High-Limit and Probe Components 1 2 3 4 5 6 7 8 9 10 11 13 14 12 15 ITEM STANDARD PART # EURO-LOOK PART # COMPONENT 1.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-30 2.8 Frypot, High-Limit and Probe Components (cont.) ITEM STANDARD PART # EURO-LOOK PART # COMPONENT * 813-0408 Plug, Frypot – .
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2-31 2.9 Wiring Connectors, Pin Terminals and Power Cords 1 2 4 5 3 6 7 9 10 8 11 13 12 ITEM PART # COMPONENT Power Cords * 807-0154 1.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS APPENDIX A-1 A.1 KJ3FC & J3F Variants – Wiring Diagrams A.1.1 Computer Wiring Diagram – KJ3FC Fast-Ready 21 68 1 3 9 7 5 2 79 1 0 1 3 5 4 21 3 1 4 1.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS APPENDIX A-2 A.1.2 J3F Wiring Diagram – (Fast /Fast Computer Modified; For Reference Only) BACK VIEW OF SWITCH HONEYWE LL 1/2 P.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS APPENDIX A-3 A.1.3 KFC-1 Computer Wiring Diagram – 120V 11 1 3 14 13 2 5 14 13 2 4 5 3 1 10 96 5 8 3 2 7 12 5 6 7 8 4 3 2 1 12 11 10 9 HI-LIMIT T'STA.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS APPENDIX A-4 A.1.4 KFC-1 Computer Wiring Diagram – 220V 11 1 3 14 13 2 5 14 13 2 4 5 3 1 10 96 5 8 3 2 7 12 5 6 7 8 4 3 2 1 12 11 10 9 HI-L IMIT T'ST.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS APPENDIX A-5 A.1.5 KSCF Wiring Di agram w/ Float (CE).
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS APPENDIX A-6 A.1.6 KFC-1 Harness Diagram.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS APPENDIX A-7 A.1.7 Transformer/Filter Bo x Wiring for FAST Computer.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS APPENDIX A-8 A.2 Parts List – KJ3FC Variant Parts specific to KJ3F C v ariants are listed here. All other parts can be foun d in Chapter 2.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS APPENDIX A-9 A.2 KJ3FC Variant – Parts List (cont.) ITEM STANDARD PART # EURO-LOOK PART # COMPO NENT 1 900-4340 Shield, Component 2 900-1739 Brace, Compon.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS APPENDIX A-10 A.2 KJ3FC Variant – Parts List (cont.) ITEM STANDARD PART # EURO-LOOK PART # COMPONENT 27 806-9325 Bracket, Support – Microswitch 28 809-0.
THIS PAGE INTENTIONALLY LEFT BLANK.
Frymaster, L.L.C., 8700 Line Av enue, PO Box 51 000, Shreveport, Louisiana 71135-1000 Shipping Address: 8700 Line Av enue, Shreveport, Louisiana 71106 TEL 1-318-865-1711 FAX (Parts) 1-31 8-688 -2200 F.
Ein wichtiger Punkt beim Kauf des Geräts Frymaster KJ3FC (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Frymaster KJ3FC noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Frymaster KJ3FC - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Frymaster KJ3FC reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Frymaster KJ3FC erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Frymaster KJ3FC besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Frymaster KJ3FC verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Frymaster KJ3FC. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Frymaster KJ3FC gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.